• Microprocessor
based design with absolutely accurate and stable
frequency.
• Panel indicators for battery voltage &
load level.
• Compact and light weight, yet very rugged
• Tightly regulated output voltage and frequency
• Switch selectable 50 or 60 Hz output,
all models
• Capable of driving highly reactive loads
such as electric tools and appliances.
• Capable of driving highly capacitive loads
such as switching power supplies.
• Very low harmonic distortion, THD<3%.
• Standard DC input 20-32VDC
• Standard outputs 110V/60Hz, 230V/50Hz.
• Switch selectable ±10V output change.
• Below 1W consumption in sleep mode.

• Ruggedization to MIL-STD-810
• Chassis slides
• MS Connector mates
• Premium wide-temp 10 year life batteries
|
|

Input Voltage: 20-32
VDC
Output Voltage 110V model:
100/110/120 VAC
Output Voltage 220V model: 220/230/240 VAC
Output Frequency: 50 or 60 HZ User Selectable
+ 0.05% Accuracy
Continuous Power Rating:1500W/2000VA
Surge Rating: 2000W/2500VA
Peak Output Current: 25 Amps
110V model / 11 Amps 230V model
Efficiency (full load): 110V model 83%
Efficiency (full load): 220V model 86%
No load Current: <1.0W Sleep Mode
Output Waveform Sinewave: <3% THD
Output Regulation: -10% / +4% All models
Protection: Overload, Short Circuit, Reverse
Polarity (Fuse), O.T., Over/Under Input Voltage
MTBF: 30,000 hours per MIL-HDBK-217
MTTR: 30 minutes by qualified personnel
Environmental
Ambient operating temperature range: -20° to +50° C
Storage temperature range: -40° to +60° C (with optional premium batteries)
For best results, batteries must be kept at 25 degrees Celsius ambient temperature. Extreme low temperatures will result in reduced run time, while extreme high temperatures result in significantly reduced battery lifespan. Click here for more information on THE EFFECTS OF EXTREME TEMPERATURES ON BATTERIES.
Humidity: to 95% RH non-condensing – Designed to meet MIL-STD-810. All boards conformal coated with Acrylic MIL-I-46058 Type R.
Shock: 20g, 11 mS half sinewave – Designed to meet MIL-STD-810 optionally
EMI: Designed to meet FCC Part 15, Class A. Designed to meet MIL-STD-461 with optional additional filtering.
Elevation:
15,000 ft. (4,572 m) operating**
40,000 ft. (12,192 m), non-operating**
**For batteries, please follow battery manufacturer instructions regarding recommended elevation parameters.
Audible noise: Less than 55 dBA at 5 ft. (1.5 m)
Transportation and handling: MIL-STD-810C
Protective Features
Circuit Breakers: DC Input & Battey Breakers
|