AET Series Free Standing
Free Standing

1 KVA – 3.2 KVA Single Phase Output Free Standing UPS

AET Series

  • Communication Equipment
  • Network Servers
  • Computers
  • Workstations
  • Wireless Communications
  • Other Electronic Pheripherals

FEATURES AND BENEFITS

Flexible Mounting Orientation
Allows system integrators more flexibility in designing their backup power system to maximize space. With the rotatable LCD design, the user can mount the UPS vertically or horizontally. 19″ Rack Mount adapters are included with each unit.

Flexible Mounting Orientation

User-Friendly Graphic LCD
This robust LCD display enables field service engineers to easily troubleshoot the UPS without opening the box thus reducing downtime.

User Friendly Graphic LCD

Single Voltage Battery Pack Design
A 48 VDC standard battery pack design comprised of 4 x 12V7AH is used in all AET series UPS models and are interchangeable with each other.
Additional battery drawers can be added to increase battery runtime.

Single Voltage Battery Pack Design

Hot-Swappable Battery
The standard 48 VDC battery pack allows installers to take the headache out of battery installation. Installers can now simply slide the used battery pack out of the unit and replace it with a new pack. All AET battery packs are interchangeable reducing the risk of system failures.

Hot Swappable Battery

Light Weight Design
The AET Model is specially designed for field installation. The light weight design requires only a single installer to put the system in place. This will significantly reduce on-the-job injuries and installation fees

Light Weight Design

User-Remote Interface
The off-site user can now test, set parameters, monitor power status, save files, and shutdown the system all via the remote interface. The user-remote interface includes SNMP/HTTP Card, RS232, USB, DB9, and AS400 interface.

User-Remote Interface

INTELLIGENT POWER MANAGEMENT SOFTWARE

  • CRUISER SOFTWARE (INCLUDED)
    Users are able to customize the various Cruiser controls such as warning method, alarm messages and several shortcut icons to easily access the most commonly used functions. The Cruiser software can send warning messages to a pager, via e-mail or over the LAN, thus providing an early warning system for power failures, system shutdown and variety of other scenarios. It guarantees a faster response time, even when you are not in the office.

    Click Here For Update Patch 1.0 For Cruiser Software.
    Original software needs to be installed first before installing the upgrade!

Cruiser Software
Features:

  • Green mode supported
  • PFC Status Display
  • Cross platform supported
  • UPS monitoring utility
  • Scheduled system shutdown
  • Graphic display of UPS status
  • Warning notification via e-mail or pager
  • Customized controls
  • User definable warnings
  • Multi-language versions
  • “Read & Write” functions when setting output voltage and frequency (Optional)

  • Interface & OS Compatibilities

RS 232 (Standard)
Windows: Win95, WinNT4.0, Win98SE, Win2000, WinMe, WinXP
Linux: 7.0 ~ 7.3, 8.0 ~ 8.4, 9.0
Mandrake: 8.2, 8.3, 8.4, 9.0
Novell: 4.x, 5.1

USB (Optional Card)
Windows: Win 98SE, Win2000, WinME, WinXP

Other major UPS monitoring software and SNMP / HTTP Cards compatible with all AET Series UPS

(For more information please contact novasales@novaelectric.com)

  • Internal or External Networking Card: Net Agent II or USHA PRO (SNMP,HTTP, PPP, TCP/IP, etc)
  • UPSilon via RS232
  • RUPS via Contact Closure (DB9)

Compatible Card
Compatible Card
Compatible Card
Compatible Card
Compatible Card

 

120 VAC MODELS
Partial Model Name AET11-1.5K AET11-2.2K AET11-3K
Outline Drawing Click Here
Topology True On-Line, Double Conversion
On-battery Output Waveform True Sinewave
Number of Phase Single (1Phase 2W + G)
Input
Maximum Capacity (VA/W) 1500VA / 1050W 2200VA / 1540W 3000VA / 2100W
Nominal Input Voltage 120 VAC
Input Voltage Range 80 to 138VAC
Nominal input Frequency 50/60 Hz +/- 5 Hz
Input PFC >0.98 @ full load
Input Short Protection Circuit Breaker on front of the UPS
Output
Nominal Output Voltage 100/110/115/120VAC
Output Voltage Regulation Rated Voltage +/-2%
Output T.H.D. <3% @ Linear
Load
High Efficiency Mode (AC to AC) >86% >88% >88%
Crest Factor 3:1
Start on Battery Yes
Output Frequency 50/60Hz (Autotracking)
Overload Capacity Sustaining at least 120 seconds at 101-110% load, 111-150% max 12 seconds.
Immediate shutdown and transfer of load to bypass at 150% load. Auto transfer back to UPS when overload is removed
Battery
User Repleaceable Battery 1 x 48VDC Battery Pack 96V (2 x 48VDC)Battery Pack 96V (2 x 48VDC)Battery Pack
Typical Backup Time (Full/Half Load) 6 / 17 minutes 9 / 26 minutes 6 / 17 minutes
Battery Type Sealed VRLA 12V7AH; Hot Swap
Recharge Time to 90% 8 Hours
Extended Battery Cabinet Extendible Battery Module in 2U high (comprises 2 x 48VDC Battery Packs)
Operation Transition from or to battery operation is accomplished with no interruption of power to the load. Upon restoration of input power, the UPS will automatically resume normal operation and recharge the battery
Advance Warning Diagnostics
Front Panel Indication Front panel menu driven LCD monitoring and control panel for all functions
Audible Alarms DC Mode, Low Battery, voltage / Frequency Error, Charger Fail, Over Load, Fault, PFC Overload/td>
Communication Interface
Communication Port RS 232 Port (Standard); DB9, AS400, USB Cards (Optional)
SNMP Maneageable Yes
Environmental
Temperature (Operation/Storage) 0 ºC to + 40 ºC / -15 to + 50 ºC
Relative Humidity 0% to 95% non-condensing
Altitude Up to 10,000 ft (3,000 meters) at up to 40 ºC, without derating
Audible Noise <45 dBA @ 1 meter
Mechanical
Dimensions – (WxHxD)
Note: Change W to 19 in. for Rack Mount Configuration
426 x 88(2U) x 500 (mm) 16.77 x 3.46 (2U) x 19.7 (in) 426 x 176 (4U) x 500 (mm) 16.67 x 6.93(4U) x 19.7 (in) 426 x 176 (4U) x 500 (mm) 16.67 x 6.93 (4U) x 19.7 (in)
Weight (UPS/Batery Packs) 26.4 / 24.6 lb 12 / 11.2 Kgs 29 / 68.7 lb 13.2 / 31.2 Kgs 29.5 / 69 lb 13.4 / 31.4 Kgs
Total Weight 51lb 23.2Kgs 97.7lb 44.4Kgs 98.5lb 44.6kgs
Conformance
EMI/RFI Compatibility FCC Part 15 Class B
Safety UL, cUL (CSA)
220 VAC MODELS
Partial Model Name AET11-1.6K AET11-2.5K AET11-3.2K
Topology True On-Line, Double
Conversion
On-battery Output Waveform True Sinewave
Number of Phase
Single (1Phase 2W + G)
Input
Maximum Capacity (VA/W)
1600VA / 1120W
2500VA / 1750W
3200VA / 2240W
Nominal Input Voltage
230 VAC
Input Voltage Range
160 to 276VAC
Nominal input Frequency
50/60 Hz +/- 5 Hz
Input PFC
>0.98 @ full
load
Input Short Protection
Circuit Breaker
on front of the UPS
Output
Nominal Output Voltage
208/220/230/240VAC
Output Voltage Regulation Rated Voltage +/-2%
Output T.H.D.
<3% @ Linear
Load
High Efficiency Mode (AC to AC) >86% >88% >88%
Crest Factor 3:1
Start on Battery Yes
Output Frequency 50/60Hz (Autotracking)
Overload Capacity Sustaining at least 120 seconds at 101-110% load, 111-150% max 12 seconds.Immediate shutdown and transfer of load to bypass at 150% load.Auto transfer back to UPS when overload is removed
Battery
User Repleaceable Battery
1 x 48VDC Battery Pack
96V (2 x 48VDC)Battery Pack
96V (2 x 48VDC)Battery Pack
Typical Backup Time (Full/Half Load)
6 / 17 minutes
9 / 26 minutes
6 / 17 minutes
Battery Type
Sealed VRLA 12V7AH;
Hot Swap
Recharge Time to 90%
8 Hours
Extended Battery Cabinet
Extendible Battery
Module in 2U high (comprises 2 x 48VDC Battery Packs)
Operation Transition from or to battery operation
is accomplished with no interruption of power to the
load. Uponrestoration of input power, the UPS will automatically
resume normal operation and recharge the battery
Advance Warning Diagnostics
Front Panel Indication
Front panel menu
driven LCD monitoring and control panel for all
functions
Audible Alarms
DC
Mode, Low Battery, voltage / Frequency Error, Charger
Fail, Over Load, Fault, PFC Overload
Communication Interface
Communication Port
RS 232 Port (Standard);
DB9, AS400, USB Cards (Optional)
SNMP Maneageable Yes
Environmental
Temperature (Operation/Storage)
0 ºC to + 40
ºC / -15 to + 50 ºC
Relative Humidity
0% to 95% non-condensing
Altitude
Up to 10,000 ft
(3,000 meters) at up to 40 ºC, without derating
Audible Noise <45 dBA @ 1
meter
Mechanical
Dimensions – (WxHxD)Note: Change W to 19 in. forRack Mount Configuration 426 x 88(2U) x 500 (mm)
16.77 x 3.46 (2U) x 19.7 (in)
426 x 176 (4U) x 500 (mm)
16.67 x 6.93(4U) x 19.7 (in)
426 x 176 (4U) x 500 (mm)16.67 x 6.93 (4U) x 19.7 (in)
Weight (UPS/Battery Packs) 26.4 / 24.6 lb 12 / 11.2 Kgs 29 / 68.7 lb 13.2 / 31.2 Kgs 29.5 / 69 lb 13.4 / 31.4 Kgs
Total Weight
51lb 23.2Kgs
97.7lb 44.4Kgs
98.5lb 44.6kgs
Conformance
EMI/RFI Compatibility
EN50091-2 ClassB,
EN55022B. IEC/EN61000-3-2 (Harmonic Current)
Safety
CE, TUV, GS