GL Series 120 VDC Nominal 2-10 KVA Pure Sine Wave DC-AC Inverters

GL Series 120 VDC Nominal 2-10 KVA Pure Sine Wave DC-AC Inverters

  • Pure Sinewave Output
  • Small Size
  • Lightweight, extremely compact
  • High reliability, MTBF exceeds 100,000 hours
  • OV, O.L. and O.T. protected
  • MTTR below 30 minutes; modular design
  • Withstands high reactive load
  • Tight voltage and frequency regulation
  • Output fault alarm (relay closure)
  • Boards are conformal coated
Compare
  • Description
  • Models
  • Specifications
  • Popular Options

Description

Legacy Series: This series is an older generation suitable for legacy military programs and other specialty applications. For new programs and most military / industrial / commercial applications, please contact us for a quote on modern replacements.

Utilizing high frequency PWM topology, these models offer volume and weight advantages suitable for severe environment and high reliability applications such as:

  • Military programs, vehicular, shipboard
  • AC Power from vehicle battery
  • Communications
  • Shelters
  • Utility Applications
105-150 VDC Operating Input / 2 KVA – 10+ KVA
(Consult factory for higher power ratings)
Standard Model Selection
60 Hz Models
60 Hz Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Rack Panel Height in. OPT/STD Outline Drawing
GL2K60-120 120 60 2KVA 28 5.75x10x17.5 7.00 or 10.50 OPT
GL2.5K60-120 120 60 2.5KVA 32 5.75×12.5×18.5 7.00 OPT pdf_icon GL2.5K60-120
GL3K60-120 120 60 3KVA 36 5.75×12.5×18.5 7.00 OPT pdf_icon GL3K60-120
GL5K60-120 120 60 5KVA 65 5.25x19x22 5.25 STD pdf_icon GL5K60-120
GL6K60-120 120 60 6KVA 65 5.25x19x22 5.25 STD pdf_icon GL6K60-120
GL10K60-120 120 60 10KVA 100 10.5x19x24 10.25 STD
50 Hz Models
50 Hz Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Rack Panel Height in. OPT/STD Outline Drawing
GL2K50-120 (220) 220 50 2KVA 28 5.75x10x17.5 7.00 or 10.50 OPT
GL2.5K50-120 (220) 220 50 2.5KVA 32 5.75×12.5×18.5 7.00 OPT pdf_icon GL2.5K50-120 (220)
GL3K50-120 (220) 220 50 3KVA 36 5.75×12.5×18.5 7.00 OPT pdf_icon GL3K50-120 (220)
GL5K50-120 (220) 220 50 5KVA 65 5.25x19x22 5.25 STD pdf_icon GL5K50-120 (220)
GL6K50-120 (220) 220 50 6KVA 65 5.25x19x22 5.25 STD pdf_icon GL6K50-120 (220)
GL10K50-120 (220) 220 50 10KVA 100 10.5x19x24 10.25 STD
400 Hz Models
400 Hz Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Rack Panel Height in. OPT/STD Outline Drawing
GL2K400-120 115 400 2KVA 28 5.75x10x17.5 7.00 or 10.50 OPT
GL2.5K400-120 115 400 2.5KVA 32 5.75×12.5×18.5 7.00 OPT pdf_icon GL2.5K400-120
GL3K400-120 115 400 3KVA 36 5.75×12.5×18.5 7.00 OPT pdf_icon GL3K400-120
GL5K400-120 115 400 5KVA 65 5.25x19x22 5.25 STD pdf_icon GL5K400-120
GL6K400-120 115 400 6KVA 65 5.25x19x22 5.25 STD pdf_icon GL6K400-120
GL10K400-120 115 400 10KVA 100 10.5x19x24 10.25 STD
3 Phase Models
3 Phase Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Rack Panel Height in. OPT/STD Outline Drawing
GL3K3/6-120 (120/208) 120/208 60 3KVA 45 5.25x19x22 5.25 STD pdf_icon GL3K3/6-120 (120/208)
GL3K3/5-120 (220/380) 220/380 50 3KVA 45 5.25x19x22 5.25 STD pdf_icon GL3K3/5-120 (220/380)
GL3K3/4-120 (115/200) 115/200 400 3KVA 45 5.25x19x22 5.25 STD pdf_icon GL3K3/4-120 (115/200)
GL4.5K3/6-120 (120/208) 120/208 60 4.5KVA 60 8.75x19x24 8.75 STD
GL4.5K3/5-120 (220/380) 220/380 50 4.5KVA 60 8.75x19x24 8.75 STD
GL4.5K3/4-120 (115/200) 115/200 400 4.5KVA 60 8.75x19x24 8.75 STD
GL6K3/6-120 (120/208) 120/208 60 6KVA 80 C/F C/F C/F
GL6K3/5-120 (220/380) 220/380 50 6KVA 80 C/F C/F C/F
GL6K3/4-120 (115/200) 115/200 400 6KVA 80 C/F C/F C/F
GL9K3/6-120 (120/208) 120/208 60 9KVA C/F C/F C/F C/F
GL9K3/5-120 (220/380) 220/380 50 9KVA C/F C/F C/F C/F
GL9K3/4-120 (115/200) 115/200 400 9KVA C/F C/F C/F C/F
GL35K3/6-120 (120/208) 120/208 60 35KVA C/F C/F N/A N/A
GL35K3/5-120 (220/380) 220/380 50 35KVA C/F C/F N/A N/A
GL35K3/4-120 (115/200) 115/200 400 35KVA C/F C/F N/A N/A
ELECTRICAL
  • Input Voltage: 105-150 VDC (Extended range available)
  • Output Voltage: See Table
  • Frequency: 50 Hz, 60 Hz, 400 Hz (+/-0.5%)
  • Frequency Regulation: +/-0.5% N.L. to F.L.
  • Voltage Regulation: +/-1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Sync & Phase Lock Range: +/-3 Hz, Typical (50/60 Hz models)
  • Transient Response: Approx. 1/4 cycle recovery to 95% of nominal
ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Standard -40°C to +71°C Optional
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A, Can meet MIL-STD-461 with additional filtering
  • Ruggedized to meet MIL-STD-810 shock,
    vibration and humidity (“R” option)
  • Wide temperature range -40°C to +71°C
  • Special output voltages and frequencies
  • Provision for 3 Phase connection with 2 more identical units
  • 19″ Panel mount (“P1” option)
  • MS Connectors or outlets
  • Custom painting and marking
  • Handles
  • High inrush for motor start
  • Transfer switch to alternate AC source
  • Wall mount plate (“W” option)
  • Chassis slides (rack mount models only)
  • Switchable 50/60 Hz output