pure sinewave DC-AC Inverters photo
Pure Sine Wave Inverter
Galaxy Series

Rugged, Lightweight Inverter

155 VDC Nominal Input

Category:

Typical 100W Unit

Typical 100W Unit

Utilizing field proven technology, this family of rugged pure sinewave DC AC Inverters is suitable for harsh environments and can be customized for unique applications including:

  • Military programs, vehicular
  • Communications
  • Cellular sites
  • Shelters
  • SATCOM terminal
  • AC power from battery
  • HMMWV applications
  • TV & Radio vans
  • Shipboard applications
  • Rapid transit & Rail Applications

Partial Standard Product Listing
120-205 VDC Operating Input / 300 VA – 1.5 KVA
(Consult factory for higher power ratings)
60 Hz Models
Models Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
NGL1260-155-120 120 60 120 VA / 100 W 2.5 2.7×4.5×7.8 pdf_icon
NGL3060-155-120 120 60 300 VA / 240 W 6 3.25x5x13.75 pdf_icon
NGL1K60-155-120 120 60 1000 VA / 800 W 6 3.25x5x13.75 pdf_icon
NGL1.5K60-155-120 120 60 1500 VA / 1200 W 6 3.25x5x13.75 pdf_icon
50 Hz Models
Models Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
NGL1250-155-220 220 50 120 VA / 100 W 2.5 2.7×4.5×7.8 pdf_icon
NGL3050-155-220 220 50 300 VA / 240 W 6 3.25x5x13.75 pdf_icon
NGL1K50-155-220 220 50 1000 VA / 800 W 6 3.25x5x13.75 pdf_icon
NGL1.5K50-155-220 220 50 1500 VA / 1200 W 6 3.25x5x13.75 pdf_icon
400 Hz Models
Models Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
NGL12400-155-115 115 400 120 VA / 100 W 2.5 2.7×4.5×7.8 pdf_icon
NGL30400-155-115 115 400 300 VA / 240 W 6 3.25x5x13.75 pdf_icon
NGL1K400-155-115 115 400 1000 VA / 800 W 6 3.25x5x13.75 pdf_icon
NGL1.5K400-155-115 115 400 1500 VA / 1200 W 6 3.25x5x13.75 pdf_icon

NGL- Model Number Selection Chart

 STANDARD FEATURES

  • • Pure Sinewave Output
  • • Compact Size
  • • Lightweight design
  • • Extremely Rugged Construction
  • • High reliability: MTBF exceeds 100,000 hours
  • • OV, O.L. and O.T. protected
  • • MTTR below 30 minutes
  • • Withstands highly reactive load
  • • Tight voltage and frequency regulation
  • • Conformal coated boards

 AVAILABLE OPTIONS

  • • Ruggedized to meet MIL-STD-810 shock, vibration and humidity
  • • Wide temperature range
  • • Special output voltages and frequencies
  • • Provision for 3 Phase connection with 2 more identical units
  • • 19″ Panel mount
  • • MS Connectors or outlets
  • • Custom painting and marking
  • • Handles
  • • High inrush for motor start
  • • Transfer switch to alternate AC source
  • • Wall mount plate
  • • Rail output voltages & frequencies (91.66, 100, 250 Hz)
  • • Customized VDC input ranges

 SPECIFICATIONS

 ELECTRICAL
  • Input Voltage:See chart above
  • Output Voltage: See chart above
  • Frequency: 50 Hz, 60 Hz, 400 Hz (±0.5%)
  • Frequency Regulation: ±0.5% N.L. to F.L.
  • Voltage Regulation: ±1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Isolation: 1500 Volt
  • Approx. 3 cycle recovery to 95% of nominal
 ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Std -30°C to +60°C Optional
  • Storage Temp: -40°C to +71°C
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A; can meet MIL-STD-461 with optional filtering