Nova Pulsar Series

Free Standing

3 KVA / 15 KVA True Online UPS

Nova Electric proudly introduces our family of 3-15 KVA True On-Line UPS Systems. This attractive new freestanding line is designed specifically for professional and commercial applications. Protect your servers ,laser printers, routers, hubs and communications equipment.

Pulsar Series UPS Specifications
MODEL P11-3K P11-4K P11-5K P11-6.25K P11-8K P11-10K P11-12K P11-15K
CAPACITY 3KVA/2.1KW 4KVA/3KW 5KVA/4KW 6.25KVA/5KW 8KVA/6.4KW 10KVA/8KW 12KVA/8.4W 15KVA/10.5W
Input
VOLTAGE CHOOSE: 100 VAC, 110VAC, 220VAC, 230VAC OR 240VAC, SINGLE PHASE; 120/208VAC OR 220/380VAC
VOLTAGE RANGE +/- 20% (OPTION +/-40%)
FREQUENCY 50Hz or 60Hz +/-5%
PHASE SINGLE OR THREE PHASE (USER MUST SPECIFY WHEN ORDERING)
Output
VOLTAGE 100VAC, 110VAC, 220VAC, 230VAC OT 240 VAC, SINGLE PHASE
VOLTAGE REGULATION +/-1%
FREQUENCY/REGULATION 50Hz OR 60 Hz WITH REGULATION BETTER THAN +/-0.5%
LOAD POWER FACTOR FROM 0.7 LAG TO 1.0 (UNITY )
HARMONIC DISTORION PURE SINEWAVE WITH LESS THAN 3% THD AT 100% LINEAR LOAD
OUTPUT LOAD CREST FACTOR MAXIMUM 3:1
Efficiency
AC TO AC >85%
Battery
BATTERY TYPE SEALED LEAD ACID BATTERY, MAINTENANCE FREE
BATTERY SIZE 12V/7AH (ALT:HR1234 HIGH RATE)
NUMBER OF BATTERIES (INTERNAL) * 16 16 16 * * * *
BACK UP TIME (ALT) MINUTES EXT 10(14) 7(11) 5(6) EXT EXT EXT EXT
RECHARGE TIME 8-10 HOURS TO 90% AFTER COMPLETE DISCHARGE
CHARGER BUILT-IN CURRENT SLECTABLE CHARGER UP TO 10 AMP OPTION
Transfer Time
AC FAULT ZERO INTERRUPTION OF THE AC OUTPUT
UPS TO BYPASS OR VICE VERSA LESS THAN 4mS
Indicator
LCD AUTOMATICALLY CONFIGURES TO MONITOR VOLTAGE, FREQUENCY , LOADING AND BATTERY SIMULTANEOUSLY, BLACKOUT & OVERLOAD HISTORICAL DATA.
LED LINE: GREEN LED; BY-PASS : YELLOW LEAD
INVERTER: GREEND LED; FAULT: RED LED
BATTERY LOW: YELLOW LEAD; OVERLOAD: YELLOW LEAD
Audible Alarm
BATTERY DISCHARGE SOUNDS EVERY 4 SECONDS, MUTE AFTER 90 SECONDS
BATTERY LOW SOUNDS EVERY SECOND
OVERLOAD CONTINUOUSLY BEEPS
FAULT CONTINUOUSLY BEEPS
Protection
OVERLOAD 150% DELAY 30 SECONDS, THEN TRANSFER TO BYPASS & AUTO RE-TRANSFER
SHORT CIRCUIT CURRENT LIMITED AND CUT-OFF, FUSE AND CIRCUIT BREAKER
BATTERY LOW BATTERY SHUTDOWN AND BATTERY CIRCUIT BREAKER
UPS FAULT BYPASS, LOAD SUPPLIED FROM THE MAINS IN LESS THAN 2mS.
EMI FILTER 10-100KHz AT 40dB; 100KHz-100 MHz AT 70dB
EMI/AMC EN50091-2, CE APPROVED
OVER TEMPERATURE INVERTER AUTO CUT-OFF WHEN HEATSINK TEMP. OVER 80°C, THEN TRANSFER TO BYPASS
Dimensions
DEPTH INCH (MM) 19.7(500) 22.8(578) 22.8(578) 22.8(578) 13.4(340) 13.4(340) 13.4(340) 15(380)
WIDTH INCH (MM) 7(180) 9.1(230) 9.1(230) 9.1(230) 18.9(480) 18.9(480) 18.9(480) 18.9(480)
HEIGHT INCH (MM) 14.2(360) 27(685) 27(685) 27(685) 33.3(685) 33.3(685) 33.3(685) 35(885)
Weight
NET WEIGHT LBS (KG) 73(33) 228(104) 238(108) 253(115) 253(115) 260(118) 264(120) 440(220)
Environment
OPERATING TEMPERATURE 0-40 °C: 32-104 °F
RELATIVE HUMIDITY UP TO 95% (NON CONDENSING )
NOISE LEVEL (AT 3 FEET) <48 dB <58dB
Interface
CONTACT CLOSURES SUPPORTS MEGATEC RUPS UPS MONITORING SOFTWARE
SMART RS-232 INTERFACE SUPPORT MEGATEC RUPS II/UPSilon 2000 MONITORING SYSTEM
Typical Discharge Times for Various Batteries and Loads for Pulsar UPS Series (1 KW – 5 KW)
KW LOAD 1.0 1.5 2.0 2.4 3.0 3.5 4.0 4.5 5.0
1 Set of (12V/7Ah battery *16) 45 24 18 14 10 9 7 6 5
1 Set of (HR1234 battery *16) 54 35 25 20 14 13 9 8 6
2 Sets of (12V/7Ah battery *16) 110 60 42 31 24 20 18 15 13
2 sets of (HR1234 battery *16) 150 86 54 45 35 24 23 19 17
3 Sets of 12V/7Ah battery *16) 180 11 74 55 42 33 26 24 21
3 Sets of (HR1234 battery *16) 230 145 100 74 54 45 36 30 27
4 Sets of (12V/7Ah battery *16) 250 160 120 80 61 51 42 35 30
4 Sets of (HR1234 battery *16) 316 195 140 105 75 64 52 45 38
5 sets of (12V/7Ah battery *16) 330 205 150 115 82 70 56 50 42
5 Sets of (HR1234 battery *16) 422 262 182 152 102 82 76 62 52
6 Sets of (12V/7Ah battery *16) 420 260 180 150 100 80 75 61 52
6 Sets of (HR1234 battery *16) 520 310 205 185 135 105 95 82 72
7 Sets of (12V/7Ah battery *16) 500 300 220 180 130 100 90 77 67
7 Sets of (HR1234 battery *16) 630 370 270 220 180 130 120 97 85
1 Set of (12V 65Ah battery *16) 680 415 300 245 195 160 140 115 97
1 Set of (12V/100Ah battery *16) 1050 710 530 390 310 260 225 194 160
1 Set of (12V/200Ah battery *16) 2100 1450 1050 890 705 595 485 425 375
Notes:
1. All battery Run times are approximate at the specified load 25 degrees centigrade.
2. Other battery choices are available, including larger free standing enclosures
3. Multiple strings of batteries can be made up by paralleing battery enclosures as appropiate
Typical Discharge Times for Various Batteries and Loads for Pulsar UPS Series (5.2 KW – 10.5 KW
)
KW LOAD 5.2 6.0 6.4 7.0 7.5 8.0 8.4 9.0 9.5 10.0 10.5
1 Set of (12V/7Ah battery *16) 4.8 4
1 Set of (HR1234 battery *16) 5 4 3
2 Sets of (12V/7Ah battery *16) 12 10 10 9 8 7 6.5 6 5.5 5 4.5
2 sets of (HR1234 battery *16) 16 14 13 12.5 12 11 9.5 8.5 8 7 6
3 Sets of 12V/7Ah battery *16) 20 18 16.5 15 13.5 12.5 12 11 10.3 9.5 9
3 Sets of (HR1234 battery *16) 25 22 20 18.5 17 15 14 13 12.5 11.5 11
4 Sets of (12V/7Ah battery *16) 29 26 24 21 19 17.5 16.5 15 14 13 12
4 Sets of (HR1234 battery *16) 36 30 28 25 22 20 19 18 17 16 15
5 sets of (12V/7Ah battery *16) 40 32 30 27 24 22 21 19 18 17 16
5 Sets of (HR1234 battery *16) 51 43 41 35 31 28 27 24 22 21 20
6 Sets of (12V/7Ah battery *16) 50 40 40 34 30 28 26 24 22 21 20
6 Sets of (HR1234 battery *16) 65 54 52 50 45 40 33 31 30 28 26
7 Sets of (12V/7Ah battery *16) 62 51 48 42 40 35 31 30 28 26 24
7 Sets of (HR1234 battery *16) 76 69 61 54 52 48 44 39 37 35 32
1 Set of (12V 65Ah battery *16) 88 79 75 66 59 54 51 47 42 39 35
1 Set of (12V/100Ah battery *16) 165 140 122 113 104 95 86 80 74 67 62
1 Set of (12V/200Ah battery *16) 360 310 299 263 240 226 210 198 187 175 160
Notes:
1. All battery Run times are approximate at the specified load 25 degrees centigrade.
2. Other battery choices are available, including larger free standing enclosures
3. Multiple strings of batteries can be made up by paralleing battery enclosures as appropiate
3KVA – 4KVA Pulsar On-Line UPS Systems 1 Phase Output
TYPICAL POPULAR
MODEL NUMBERS
KVA KW I/O
FREQ
INPUT
VAC
OUTPUT
VAC
UPS
EST
Kgs
UPS
EST
Lbs
SIZE(in) SIZE(mm) BATTERY RUN TIME
(MIN)
W D H W D H
P11-3K60-120-120 3 2.1 60 120 120 33 73 180 500 360 7.0 19.7 14.2 EXTERNAL N/A
P11-3K60-120/208-120 3 2.1 60 120/208 120 33 73 180 500 60 7.0 19.7 14.2 EXTERNAL N/A
P11-3K50-220-220 2 2.1 50 220 220 33 73 180 500 360 7.0 19.7 14.2 EXTERNAL N/A
P11-3K50-220-220 3 2.1 50 220 220 33 73 180 500 360 7.0 19.7 14.2 EXTERNAL N/A
P11-4K60-120-120 4 3 60 120 120 60 123 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-4K60-120/208-120 4 3 60 120/208 120 60 123 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-4K50-220-220 4 3 50 220 220 60 123 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-4K50-220/380-220 4 3 50 220/380 220 60 123 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-4K60-120-120-10M 4 3 60 120 120 104 228 230 578 685 9.1 22.8 27 12V7 AH 16PCS 10
P11-4K50-220-220-10M 4 3 50 220 220 104 228 230 578 685 9.1 22.8 27 12V7 AH 16PCS 10
P11-4K60-120-120-14M 4 3 60 120 120 106 233 230 578 685 9.1 22.8 27 HR1234, 16 PCS 14
P11-4K50-220-220-14M 4 3 50 220 220 106 233 230 578 685 9.1 22.8 27 HR1234, 16 PCS 14
Battery Packs
PPC12/7-16-XXK 53 117 180 500 360 7 19.7 14.2 12V7 AH 16PCS
PPC12/7-32-XX 130 286 480 340 845 18.9 13.4 33.3 12V7 AH 32 PCS
PPC12/7-48-XXK 170 374 480 340 845 18.9 13.4 33.3 12V7 AH 48 PCS
PPCHR1234-16-XXK 56 123 180 500 360 7 19.7 14.2 HR1234, 16 PCS
PPCHR1234-32-XXK 132 290 480 340 845 18.9 13.4 33.3 HR1234, 32 PCS
PPCHR1234-48-XXK 173 380 480 340 845 18.9 13 33 HR1237, 48 PCS
5KVA – 15KVA Pulsar On-Line UPS Systems 1 Phase Output
TYPICAL POPULAR
MODEL NUMBERS
KVA KW I/O
FREQ
INPUT
VAC
OUTPUT
VAC
UPS
EST
Kgs
UPS
EST
Lbs
SIZE(in) SIZE(mm) BATTERY RUN TIME
(MIN)
W D H W D H
P11-5K60-120-120 5 4 60 120 120 67 147 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-5K60-120/208-120 5 4 60 120/208 120 67 147 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-5K50-220-220 5 4 50 220 220 67 147 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-5K50-220/380-220 5 4 50 220/380 220 67 147 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-5K60-120-120-7M 5 4 60 120 120 108 238 230 578 685 9.1 22.8 27 12V7 AH 16 PCS 7
P11-5K50-220-220-7M 5 4 50 220 220 108 238 230 578 685 9.1 22.8 27 12V7 AH 16 PCS 7
P11-5K60-120-120-10M 5 4 60 120 120 110 242 230 578 685 9.1 22.8 27 HR1234, 16 PCS 11
P11-5K50-220-220-10M 5 4 50 220 220 110 242 230 578 685 9.1 22.8 27 HR1234, 16 PCS 11
P11-6.25K60-120-120 6.25 5 60 120 120 74 163 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-6.25K60-120/208-120 6.25 5 60 120/208 120 74 163 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-6.25K50-220-220 6.25 5 50 220 220 74 163 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-6.25K50-220/380-220 6.25 5 50 220/380 220 74 163 230 578 685 9.1 22.8 27 EXTERNAL N/A
P11-6.25K60-120-120-5M 6.25 5 60 120 120 115 256 230 578 685 9.1 22.8 27 12V7 AH 16 PCS 5
P11-6.25-K50-220-220-5M 6.25 5 50 220 220 115 253 230 578 685 9.1 22.8 27 12V7 AH 16 PCS 5
P11-6.25K60-120-120-6M 6.25 5 60 120 120 117 257 230 578 685 9.1 22.8 27 HR1234, 16 PCS 6
P11-6.25K50-2220-220-6M 6.25 5 50 220 220 117 257 230 578 685 9.1 22.8 27 HR1234, 16 PCS
P11-8K60-120-120 8 6.4 60 120 120 115 253 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-8K60-120/208-120 8 6.4 60 120/208 120 115 253 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-8K50-220-220 8 6.4 50 220 220 115 253 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-8K50-220/380-220 8 6.4 50 220/380 220 115 253 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-10K60-120-120 10 8 60 120 120 118 260 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-8K60-120/208-120 10 8 60 120/208 120 118 253 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-10K50-220-220 10 8 50 220 220 118 260 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-10K50-220/380-220 10 8 50 220/380 220 118 260 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-12K60-120/208-120 12 8.4 60 120 120 120 264 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-12K60-120/208-120 12 8.4 60 120/208 120 120 264 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-12K50-220-220 12 8.4 50 220 220 120 264 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-12K50-220/380-220 12 8.4 50 220/380 220 120 264 480 340 845 18.9 13.4 33.3 EXTERNAL N/A
P11-15K60-120/208-120 15 10.5 60 120/208 120 200 440 480 380 885 18.9 15 35 EXTERNAL N/A
P11-15K50-220/380-220 15 10.5 50 220/380 220 200 440 480 380 885 18.9 15 35 EXTERNAL N/A
Notes:
1. External battery packs can be mixed to obtain longer run times. Battery voltage is always 192VDC nominal.
2. Extended warranty is available.
3. Local on site service for turn-on preventive maintenance is offered by factory engineers.
4. Spare parts kits are available depending on needs.
5. EPO option to trip AC and DC breaker available.
6. Replace the XX in the battery pack model with the KVA rating of the matching UPS.
7. Ruggedizing option is available.
8. All above units are 50 or 60 Hz in and out as shown. Units with other inputs and outputs are available.

 STANDARD FEATURES

  • • Double conversion, IGBT model, true on-line isolated UPS.
  • • Unique AVR built-in for super wide input voltage range.
  • • Special air-flow control, suitable for any dirty operation environment.
  • • User friendly design and simple operation.
  • • Single control board design, for easy maintenance.
  • • Constant power, special overload capacity design.
  • • One touch LCD Display designs; it’s very easy to operate.
  • • MTTR (Mean Time To Replacement) < 30 minutes.
  • • MTBF (Mean Time Before Failure) > 8000 hrs.
  • • CE approved
  • • All models from 3K to 10KVA are used the same Main PCB. Customers only need to keep one board for RMA service.
    a. Full Protection
    b. Overload protection
    c. Short circuit protection
    d. Overload constant power protection
    e. Static switch protection
    f. Over temperature protection
    g. DC BUS start-up with current protection
    h. Charger board start up: 2-4 seconds delay
    i. Two stage phase Lock Loop
    j. This series could be connected with generator.
  • • Option to schedule UPS on/off times
  • • The control board and other main components are in the front side that is very easy to do the maintenance service.
  • • Built-in high capacity battery charger for long backup time.
  • • Front side operation design for easy installation and maintenance
  • • Very compact and light design easy to fit into any office corner.
  • • Smart communication function support MEGATEC RUPSII monitoring software.
  • • Parallel operation (optional) Connect up to 8 units to increase the capacity.
  • • The charger board is designed for CCV (Constant Current Constant Voltage) that could extend the battery life two times (3-6 years) including the battery high voltage protection and O/P short circuit protection.
The appearance of U.S. Department of Defense (DoD) visual information does not imply or constitute DoD endorsement.