Jupiter Series 10-450+ KVA True Online UPS Systems

  • Complete input to output Galvanic Isolation.
  • High frequency (almost silent) operation
  • Push button starting and stopping
  • Diagnostic panel with LCD and LED display
  • Soft start on inverter
  • Overload & and short circuit protection on charger and inverter
  • Maintenance free batteries
  • True Online operation
  • Solid state transfer switch standard at no additional charge
  • Maintenance bypass switch standard at no additional charge
  • All electronics are built in modular front-access cabinets and have front removable subassemblies for easy service and maintenance
  • Batteries may be built into units up to 20KVA
  • Automatic dual rate battery charger (float charge and boost charge)
  • FCC class A approved
  • Remote isolated dry relay contacts
  • Available options to meet military specs
Compare Compare

Description

Nova’s Jupiter-Series UPS Systems are high-reliability power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-167, MIL-STD-461, and other standards optionally. Standard models are three-phase input and output, and single-phase configurations are available upon request. Specialty frequencies including 400 Hz for aircraft are available upon request as well. These models utilize True On-Line technology and the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications such as:

  • Military Applications: Including Shipboard, Submarine, Aircraft, Mobile Power Units, Shelters, Transportable Systems, Tactical Systems, Ground Support, and more
  • Heavy-Duty Industrial Applications
  • Demanding Commercial Applications
  • Communications Systems
  • MIL-STD-810
  • MIL-STD-461
  • MIL-S-901
  • MIL-STD-167

 

STANDARD MODEL SELECTION

(All Popular Input/Output Voltages and Frequencies are Available)

Partial Three-Phase 60 Hz Model Selection

MODEL KVAKWIN / OUT (VAC)DIMENSIONS (HXWXD)UPS WEIGHT (KG)UPS WEIGHT (LB)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HXWXD)BATTERY WEIGHT (KG.)BATTERY WEIGHT (LBS.)
J11-10K3/6-120/208-120/208-10M108120/208 63″ x 22″ x 31.5″300660HR1234 12V 29pcs 10Internal 85187
QUOTE
J11-20K3/6-120/208-120/208-10M2016120/208 63″ x 22″ x 31.5″400880HR1234 12V 58pcs 10Internal 170374 QUOTE
J11-30K3/6-120/208-120/2083024120/208 63″ x 22″ x 31.5″470103412V 26AH 29pcs 963″x22″31.5″410900 QUOTE
J11-30K3/6-120/208-120/2083024120/208 63″ x 22″ x 31.5″470103412V 26AH 58pcs 2463″x22″31.5″6901520 QUOTE
J11-30K3/6-120/208-120/2083024120/208 63″ x 22″ x 31.5″470103412V 75AH 29pcs 2963″ x 43.5″ x 31.5″10202245 QUOTE
J11-40K3/6-120/208-120/2084032120/208 63″ x 22″ x 31.5″530116612V 26AH 29pcs 763″ x 43.5″ x 31.5″410900 QUOTE
J11-40K3/6-120/208-120/2084032120/208 63″ x 22″ x 31.5″530116612V 26AH 58pcs 1863″x22″31.5″6901520 QUOTE
J11-40K3/6-120/208-120/2084032120/208 63″ x 22″ x 31.5″530116612V 75AH 29pcs 2363″ x 43.5″ x 31.5″10202245 QUOTE
J11-50K3/6-120/208-120/2085040120/208 63″ x 22″ x 31.5″560123212V 26AH 58pcs 1363″x22″31.5″6901520 QUOTE
J11-50K3/6-120/208-120/2085040120/208 63″ x 22″ x 31.5″560123212V 75AH 29pcs 1663″ x 43.5″ x 31.5″10202245
QUOTE
J11-60K3/6-120/208-120/2086048120/208 63″ x 22″ x 31.5″630138612V 26AH 58pcs 963″x22″31.5″6901520
QUOTE
J11-60K3/6-120/208-120/2086048120/208 63″ x 22″ x 31.5″630138612V 75AH 29pcs 1363″ x 43.5″ x 31.5″10202245 QUOTE
J11-80K3/6-120/208-120/2088064120/208 63” x 43.5” x 31.5”9802156 63″ x 22″ x 31.5″ 863″ x 43.5″ x 31.5″10202245
QUOTE
J11-100K3/6-120/208-120/20810080120/208 63” x 43.5” x 31.5”1290283812V 88AH 29pcs 663″ x 43.5″ x 31.5″11302485 QUOTE
J11-120K3/6-120/208-120/20812096120/208 63” x 43.5” x 31.5”1400308012V 100AH 29pcs 663″ x 43.5″ x 31.5″1270 2795 QUOTE
J11-160K3/6-120/208-120/208160128120/208 63” x 43.5” x 31.5”1620365412V 75AH 58pcs 763″ x 2x(43.5)″ x 31.5″20404490
QUOTE
J11-200K3/6-277/480-277/480200160277/480 63” x 87” x 31.5”2450539012V 88AH 58pcs 663″ x 2x(43.5)″ x 31.5″22604970 QUOTE
J11-240K3/6-277/480-277/480240192277/480 63” x 87” x 31.5”2620576012V 100AH 58pcs 663″ x 2x(43.5)″ x 31.5″25405590 QUOTE
J11-240K3/6-277/480-277/480240192277/480 63” x 87” x 31.5”2620 576012V 75AH 87pcs 863″ x 3x(43.5)″ x 31.5″30606730
QUOTE
J11-300K3/6-277/480-277/480300240277/480 63” x 87” x 31.5”28006160 12V 88AH 87pcs 863″ x 3x(43.5)″ x 31.5″33907460 QUOTE
J11-320K3/6-277/480-277/480320256277/480 63” x 87” x 31.5”2960651012V 88AH 87pcs 663″ x 3x(43.5)″ x 31.5″33907460 QUOTE
J11-320K3/6-277/480-277/480320256277/480 63” x 87” x 31.5”2960651012V 100AH 87pcs 863″ x 3x(43.5)″ x 31.5″38108380
QUOTE

Partial Three-Phase 50 Hz Model Selection
MODEL KVAKWIN / OUT (VAC)DIMENSIONS (HXWXD)UPS WEIGHT (KG)UPS WEIGHT (LB)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HXWXD)BATTERY WEIGHT (KG.)BATTERY WEIGHT (LBS.)
J11-10K3/5-220/380-220/380-10M108220/38063″ x 22″ x 31.5″300660HR1234 12V 29pcs 10Internal 85187
QUOTE
J11-20K3/5-220/380-220/380-10M2016220/38063″ x 22″ x 31.5″400880HR1234 12V 58pcs 10Internal 170374 QUOTE
J11-30K3/5-220/380-220/3803024220/38063″ x 22″ x 31.5″470103412V 26AH 29pcs 963″x22″31.5″410900 QUOTE
J11-30K3/5-220/380-220/3803024220/38063″ x 22″ x 31.5″470103412V 26AH 58pcs 2463″x22″31.5″6901520 QUOTE
J11-30K3/5-220/380-220/3803024220/38063″ x 22″ x 31.5″470103412V 75AH 29pcs 2963″ x 43.5″ x 31.5″10202245 QUOTE
J11-40K3/5-220/380-220/3804032220/38063″ x 22″ x 31.5″530116612V 26AH 29pcs 763″ x 43.5″ x 31.5″410900 QUOTE
J11-40K3/5-220/380-220/3804032220/38063″ x 22″ x 31.5″530116612V 26AH 58pcs 1863″x22″31.5″6901520 QUOTE
J11-40K3/5-220/380-220/3804032220/38063″ x 22″ x 31.5″530116612V 75AH 29pcs 2363″ x 43.5″ x 31.5″10202245 QUOTE
J11-50K3/5-220/380-220/3805040220/38063″ x 22″ x 31.5″560123212V 26AH 58pcs 1363″x22″31.5″6901520 QUOTE
J11-50K3/5-220/380-220/3805040220/38063″ x 22″ x 31.5″560123212V 75AH 29pcs 1663″ x 43.5″ x 31.5″10202245
QUOTE
J11-60K3/5-220/380-220/3806048220/38063″ x 22″ x 31.5″630138612V 26AH 58pcs 963″x22″31.5″6901520
QUOTE
J11-60K3/5-220/380-220/3806048220/38063″ x 22″ x 31.5″630138612V 75AH 29pcs 1363″ x 43.5″ x 31.5″10202245 QUOTE
J11-80K3/5-220/380-220/3808064220/38063” x 43.5” x 31.5”9802156 63″ x 22″ x 31.5″ 863″ x 43.5″ x 31.5″10202245
QUOTE
J11-100K3/5-220/380-220/38010080220/38063” x 43.5” x 31.5”1290283812V 88AH 29pcs 663″ x 43.5″ x 31.5″11302485 QUOTE
J11-120K3/5-220/380-220/38012096220/38063” x 43.5” x 31.5”1400308012V 100AH 29pcs 663″ x 43.5″ x 31.5″1270 2795 QUOTE
J11-160K3/5-220/380-220/380160128220/38063” x 43.5” x 31.5”1620365412V 75AH 58pcs 763″ x 2x(43.5)″ x 31.5″20404490
QUOTE
J11-200K3/5-220/380-220/380200160220/38063” x 87” x 31.5”2450539012V 88AH 58pcs 663″ x 2x(43.5)″ x 31.5″22604970 QUOTE
J11-240K3/5-220/380-220/380240192220/38063” x 87” x 31.5”2620576012V 100AH 58pcs 663″ x 2x(43.5)″ x 31.5″25405590 QUOTE
J11-240K3/5-220/380-220/380240192220/38063” x 87” x 31.5”2620 576012V 75AH 87pcs 863″ x 3x(43.5)″ x 31.5″30606730
QUOTE
J11-300K3/5-220/380-220/380300240220/38063” x 87” x 31.5”28006160 12V 88AH 87pcs 863″ x 3x(43.5)″ x 31.5″33907460 QUOTE
J11-320K3/5-220/380-220/380320256220/38063” x 87” x 31.5”2960651012V 88AH 87pcs 663″ x 3x(43.5)″ x 31.5″33907460 QUOTE
J11-320K3/5-220/380-220/380320256220/38063” x 87” x 31.5”2960651012V 100AH 87pcs 863″ x 3x(43.5)″ x 31.5″38108380
QUOTE

Partial Three-Phase 400 Hz Model Selection
MODEL KVAKWIN / OUT (VAC)DIMENSIONS (HXWXD)UPS WEIGHT (KG)UPS WEIGHT (LB)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HXWXD)BATTERY WEIGHT (KG.)BATTERY WEIGHT (LBS.)
J11-10K3/4-115/200-115/200-10M108115/20063″ x 22″ x 31.5″300660HR1234 12V 29pcs 10Internal 85187
QUOTE
J11-20K3/4-115/200-115/200-10M2016115/20063″ x 22″ x 31.5″400880HR1234 12V 58pcs 10Internal 170374 QUOTE
J11-30K3/4-115/200-115/2003024115/20063″ x 22″ x 31.5″470103412V 26AH 29pcs 963″x22″31.5″410900 QUOTE
J11-30K3/4-115/200-115/2003024115/20063″ x 22″ x 31.5″470103412V 26AH 58pcs 2463″x22″31.5″6901520 QUOTE
J11-30K3/4-115/200-115/2003024115/20063″ x 22″ x 31.5″470103412V 75AH 29pcs 2963″ x 43.5″ x 31.5″10202245 QUOTE
J11-40K3/4-115/200-115/2004032115/20063″ x 22″ x 31.5″530116612V 26AH 29pcs 763″ x 43.5″ x 31.5″410900 QUOTE
J11-40K3/4-115/200-115/2004032115/20063″ x 22″ x 31.5″530116612V 26AH 58pcs 1863″x22″31.5″6901520 QUOTE
J11-40K3/4-115/200-115/2004032115/20063″ x 22″ x 31.5″530116612V 75AH 29pcs 2363″ x 43.5″ x 31.5″10202245 QUOTE
J11-50K3/4-115/200-115/2005040115/20063″ x 22″ x 31.5″560123212V 26AH 58pcs 1363″x22″31.5″6901520 QUOTE
J11-50K3/4-115/200-115/2005040115/20063″ x 22″ x 31.5″560123212V 75AH 29pcs 1663″ x 43.5″ x 31.5″10202245
QUOTE
J11-60K3/4-115/200-115/2006048115/20063″ x 22″ x 31.5″630138612V 26AH 58pcs 963″x22″31.5″6901520
QUOTE
J11-60K3/4-115/200-115/2006048115/20063″ x 22″ x 31.5″630138612V 75AH 29pcs 1363″ x 43.5″ x 31.5″10202245 QUOTE
J11-80K3/4-115/200-115/2008064115/20063” x 43.5” x 31.5”9802156 63″ x 22″ x 31.5″ 863″ x 43.5″ x 31.5″10202245
QUOTE
J11-100K3/4-115/200-115/20010080115/20063” x 43.5” x 31.5”1290283812V 88AH 29pcs 663″ x 43.5″ x 31.5″11302485 QUOTE
J11-120K3/4-115/200-115/20012096115/20063” x 43.5” x 31.5”1400308012V 100AH 29pcs 663″ x 43.5″ x 31.5″1270 2795 QUOTE
J11-160K3/4-115/200-115/200160128115/20063” x 43.5” x 31.5”1620365412V 75AH 58pcs 763″ x 2x(43.5)″ x 31.5″20404490
QUOTE

PARTIAL THREE-PHASE FREQUENCY CONVERTER / UPS MODEL CHART

Partial Three-Phase 60 Hz Input Frequency Converter / UPS Model Selection
MODEL KVAKWIN (VAC)OUT (VAC)DIMENSIONS (HxWxD)UPS WEIGHT (LBS)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HxWxD)BATTERY WEIGHT (LBS.)
J11-10K3/5-120/208-220/380-10M108120/208 60 Hz220/380 50 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs 10Internal 187
QUOTE
J11-10K3/4-120/208-115/200-10M108120/208 60 Hz115/200 400 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs 10Internal 187 QUOTE
J11-20K3/5-120/208-220/380-10M2016120/208 60 Hz220/380 50 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs 10Internal 374 QUOTE
J11-20K3/4-120/208-115/200-10M2016120/208 60 Hz115/200 400 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs 10Internal 374 QUOTE
Partial Three-Phase 50 Hz Input Frequency Converter / UPS Model Selection
MODEL KVAKWIN (VAC)OUT (VAC)DIMENSIONS (HxWxD)UPS WEIGHT (LBS)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HxWxD)BATTERY WEIGHT (LBS.)
J11-10K3/6-220/380-120/208-10M108220/380 50 Hz120/208 60 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-10K3/4-120/208-115/200-10M108220/380 50 Hz115/200 400 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-20K3/6-220/380-120/208-10M2016220/380 50 Hz120/208 60 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE
J11-20K3/4-220/380-115/200-10M2016220/380 50 Hz115/200 400 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE
Partial Three-Phase 400 Hz Input Frequency Converter / UPS Model Selection
MODEL KVAKWIN (VAC)OUT (VAC)DIMENSIONS (HxWxD)UPS WEIGHT (LBS)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HxWxD)BATTERY WEIGHT (LBS.)
J11-10K3/6-220/380-120/208-10M108115/200 400 Hz120/208 60 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-10K3/5-220/380-115/200-10M108115/200 400 Hz220/380 50 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-20K3/6-220/380-120/208-10M2016115/200 400 Hz120/208 60 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE
J11-20K3/5-220/380-115/200-10M2016115/200 400 Hz220/380 50 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE

PARTIAL SINGLE-PHASE UPS MODEL CHART

Partial Single-Phase UPS Model Selection
MODEL KVAKWINPUTOUTPUTDIMENSIONS (HxWxD)UPS WEIGHT (LBS)BATTERYRUN TIME (MIN.)BATTERY DIMENSIONS (HxWxD)BATTERY WEIGHT (LBS.)
J11-10K60-120-120-10M108120 VAC 60 Hz120 VAC 60 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-10K60-120-120-20M108120 VAC 60 Hz120 VAC 60 Hz63″ x 22″ x 31.5″660HR1234 12V 58pcs20Internal374 QUOTE
J11-10K50-120-220-10M108120 VAC 60 Hz220 VAC 50 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-10K50-120-220-20M108120 VAC 60 Hz220 VAC 50 Hz63″ x 22″ x 31.5″660HR1234 12V 58pcs20Internal374 QUOTE
J11-10K400-120-115-10M108120 VAC 60 Hz115 VAC 400 Hz63″ x 22″ x 31.5″660HR1234 12V 29pcs10Internal187 QUOTE
J11-10K400-120-115-20M108120 VAC 60 Hz115 VAC 400 Hz63″ x 22″ x 31.5″660HR1234 12V 58pcs20Internal374 QUOTE
J11-15K60-120-120-5M1512120 VAC 60 Hz120 VAC 60 Hz63″ x 22″ x 31.5″750HR1234 12V 29pcs5Internal187 QUOTE
J11-15K60-120-120-15M1512120 VAC 60 Hz120 VAC 60 Hz63″ x 22″ x 31.5″750HR1234 12V 58pcs15Internal374 QUOTE
J11-15K50-120-220-5M1512120 VAC 60 Hz220 VAC 50 Hz63″ x 22″ x 31.5″750HR1234 12V 29pcs5Internal187 QUOTE
J11-15K50-120-220-15M1512120 VAC 60 Hz220 VAC 50 Hz63″ x 22″ x 31.5″750HR1234 12V 58pcs15Internal374 QUOTE
J11-15K400-120-115-5M1512120 VAC 60 Hz115 VAC 400 Hz63″ x 22″ x 31.5″750HR1234 12V 29pcs5Internal187 QUOTE
J11-15K400-120-115-15M1512120 VAC 60 Hz115 VAC 400 Hz63″ x 22″ x 31.5″750HR1234 12V 58pcs15Internal374 QUOTE
J11-20K60-120-120-10M2016120 VAC 60 Hz120 VAC 60 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE
J11-20K50-120-220-10M2016120 VAC 60 Hz220 VAC 50 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE
J11-20K400-120-115-10M2016120 VAC 60 Hz115 VAC 400 Hz63″ x 22″ x 31.5″880HR1234 12V 58pcs10Internal374 QUOTE
J11-30K60-120-1203024120 VAC 60 Hz120 VAC 60 Hz63″ x 22″ x 31.5″1034Select:
26AH x 29
26AH x 58
75AH x 29

9
24
29

63″ x 22″ x 31.5″
63″ x 22″ x 31.5″
63″ x 43.5″ x 31.5″

900
1520
2245
QUOTE
J11-30K50-120-2203024120 VAC 60 Hz220 VAC 50 Hz63″ x 22″ x 31.5″1034Select:
26AH x 29
26AH x 58
75AH x 29

9
24
29

63″ x 22″ x 31.5″
63″ x 22″ x 31.5″
63″ x 43.5″ x 31.5″

900
1520
2245
QUOTE
J11-30K400-120-1153024120 VAC 60 Hz115 VAC 400 Hz63″ x 22″ x 31.5″1034Select:
26AH x 29
26AH x 58
75AH x 29

9
24
29

63″ x 22″ x 31.5″
63″ x 22″ x 31.5″
63″ x 43.5″ x 31.5″

900
1520
2245
QUOTE
Specifications for the Nova Electric Jupiter-Series Three-Phase True Online UPS Series
PHASE 3-Phase Input / 3-Phase Output
KVA 10 20 30 40 50 60 80 100 120 160 240 300/320
Input Rectifier
Input Voltage (VAC) Please Specify 115/200, 120/208, 220/380,230/400, 240/415, or 277/480 WYE
220 3-Phase delta, 240 3-Phase delta, 380 3-Phase delta, or 480 3-Phase delta
Input Range +/- 20% (>+20% is available upon request)
Input Frequency 50/ 60 + 5Hz
Power Walk In 0% – 100% :20 sec
Voltage Regulation +/- 1%
Efficiency 98%
Rectification Type 6 Pulse Standard, 12 Pulse Optional 12 Pulse Standard
Battery
Battery Type Maintenance free lead-acid batteries/ 12V x 29pcs. (348 VDC Nominal)
Maximum Charge Current(Adc Selectable)LO,MED,HI 4 8 12 16 25 26 32 45 50 65 100 130
Battery Start Yes, UPS can be started without AC source.
Inverter
Output Voltage (VAC) Please Specify 115/200, 120/208, 220/380,230/400, 240/415, or 277/480 WYE
220 3-Phase delta, 240 3-Phase delta, 380 3-Phase delta, or 480 3-Phase delta
Wave Form Sinewave
Output Power Factor 0.8
Frequency Lock Range 50 / 60 Hz +/- 3 Hz
Output Frequency (Free Running) 50 / 60 Hz +0.1 Hz (crystal controlled)
Output Power Factor 0.7 lead to lag
Phase Shift Under 100% Unbalanced Load <0.5%
THD (Linear Load)
< 2%
Overload
<110% Continuous
>110-125% Up to 15 minutes
>125-150% Up to 5 minutes
>150-170% Up to 30 seconds
>170-200% Up to 15 seconds
Efficiency (100% Load) 93% 93% 93% 93.5% 93.5% 94% 94.5% 94.5% 95% 95% 95% 95%
STATIC SWITCH
Voltage Range Same as Main Rectifier Input.(Different voltages are available upon request)
Mains <-> Inverter 0 ms (True Online)
Overload As per inverter rating plus >200% to 300% = 1 second
OVERALL CHARACTERISTICS
Overall Efficiency 91% 91% 91% 91.5% 92% 92% 92.5% 92.5% 93% 93% 93% 93%
Maximum Heat Dissipation (kw) 0.7 1.4 1.9 2.6 3 3.5 4.6 5.4 6.5 8.7 13 17.4
BTU/h @ Full Load 2.4K 4.8K 6.5K 8.9K 10.3K 12K 16K 19K 22K 30K 45K 60K
Audible Noise <65 dBA (at 1m) <67dBA (at 1m)
Temperature 0-40ºC (32-104ºF)(Other ranges available)
Humidity 0%-95% (Non-condensing)
Altitude <1500 m Above Sea Level
MTTR Less Than 30 minutes
IEC 62040-2 Yes for 220/380VAC 50Hz Models No
EN50091-1, -2 Yes
Short Circuit Protection Yes
MTBF As per MIL-HDBK-217: 30,000 Hours
As per Field Experience >100,000 Hours for loss of AC Output
Lightning / EMC Filter MOV / Input & Output ( FCC Class A)
Galvanic Isolation Input and Output True Galvanic Isolation
LED, LCD, Audible Alarm Yes
Remote Control and Communication Interface Choices Dry Contact, RS-232, RS-485 (Optional,) UPScan Monitoring 1~99 Units Simultaneously (Optional,) Netagent (Optional,) MODBUS (Optional)

MONITORING FEATURES

  • The unit includes an RS232 communication option called UPSCOM which can monitor the output parameters and any abnormal conditions that have occurred in real time.

FRONT PANEL LCD DISPLAY AND LED INDICATORS

  • This will report all UPS parameters including input and output voltages, currents, frequency, battery voltage, battery current, and many other functions.

LCD DISPLAY

  • Real time status, data, and historical events are displayed via the LCD display. The UPS parameters, real-time clock, inverter, and buzzer can also be set through this LCD, which is backlit by LEDs for visual clarity.

STATUS LEDs

LEDs representing all important operational information provide feedback to the user. LED descriptions are as follows:

  • UPS ON – UPS is running normally.
  • UPS SS – UPS static switch is on while the reserve static switch is opened (off).
  • SHORT CIRCUIT – UPS output is in short circuit state.
  • FUSE / OVERTEMP SD – UPS has shut down due to either fuse open or over temperature.
  • UPS FAIL SHUTDOWN – UPS has shut down due to low inverter AC output voltage.
  • BYPASS ON SHUTDOWN –UPS shut down due to closed bypass breaker. UPS shut down due closed bypass breaker (while inverter running).
  • HIGH DC SHUTDOWN – UPS shut down due to high DC bus.
  • OVERLOAD SHUTDOWN – UPS shutdown due to overload of the inverter for a period greater than the inverter can accept. The UPS will start after 7 seconds.
    70% LOAD – load connected to the output is over 70% of the Inverter rating.
    110% LOAD – load connected to the output is over 110% oh the Inverter rating.
    125% LOAD – load connected to the output is over 125% of the Inverter rating.
    150% LOAD – load connected to the output is over 150% of the Inverter rating.
  • RESERVE AC FAIL – reserve AC magnitude is out of range.
  • RESERVE FREQ FAIL – reserve frequency is out of range.
  • BATTERY LOW – DC bus (or battery) is lower than specified range, low battery shutdown will occur soon.
  • BATTERY LOW SHUTDOWN – inverter shutdown due to DC bus (or battery) lower than the acceptable DC voltage of the inverter.
  • HIGH DC – DC voltage over the acceptable DC voltage of the inverter.
  • EMERGENCY STOP – Inverter shut down activated by emergency stop switch.
  • DATA LINE – Blink when data is transmitted to or received from the communication port

WARNING LEDs

When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. These LEDs are:

  • RESERVE FAIL – Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range.
  • FUSE/TEMP – Either inverter fuse is open or over temperature has occurred.
  • OVERLOAD – Output is overloaded by over 110%, 125% or 150%
  • HIGH DC – This LED will light when DC input approaches high-line limit.
  • BAT LOW – This LED will light when the DC voltage is low.
  • BAT LOW STOP – This LED will light when the DC voltage is lower than specified range.
  • FAULT – The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop.

AUDIBLE ALARM

The audible alarm will beep under either one of the following conditions:

  • INVERTER IS OVERLOADED
    > 110% beep once every 3 seconds
    > 125% beep once every second
    > 150% beep twice every second
  • INVERTER IS SHORT CIRCUITED – Beeps continuously
  • FUSE OPEN– Beeps continuously
  • HEAT SINK OVER TEMPERATURE – Beeps continuously
  • HIGH DC SHUTDOWN – Beeps continuously
  • BYPASS ON STOP – Beeps continuously
  • EMERGENCY ON STOP – Beeps continuously
    The buzzer will also beep once every time the inverter is switched on or off to acknowledge to the user that his key entry is valid and accepted.temperature, bypass breaker on emergency stop.

 

OPTIONS

  • Battery Disconnect: The optional battery disconnect is offered to provide protection for the batteries.  The electrical code requires a disconnect near the batteries.  We will mount this disconnect inside the battery enclosure, if ordered.  This option is strongly recommended.
  • Ruggedization: Ruggedization is highly recommended for harsh environment applications, and includes conformal coating of the UPS’s PCBs to protect against humidity, condensation, and fungus growth. For military applications, we offer more structural ruggedization, as well as shock mounts, to comply with such standards as MIL-S-901, MIL-STD-810, and other demanding MIL-Specs. This option does not affect size or weight.
  • UPScan Remote Monitor Panel: This is a hand held remote display and control module with LCD and LED display that can monitor up to 99 UPSs at a remote distance of up to 3,000 feet via RS-485.
  • NETAGENT:  This provides capability to monitor the UPS over the internet.  It includes the appropriate additional SNMP card and microprocessor.  The software required is provided by Megatec at additional cost.  When equipped with this option, the user can connect a CAT-5 cable for interface to the external LAN.
  • DCMON:  This is a battery monitor module for all the batteries in each 29 battery string.  This feature can provide information on a defective battery before problems cascade to other batteries in the total battery bank.  Each battery’s condition is reported to a user viewable battery display unit which will tell the user the status of each battery. One display is required per each 29 battery string.
  • Complete Spare Parts Package: We offer a comprehensive spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans.  These spare parts kits are priced lower when ordered with the initial order then if they are ordered later on.
  • Factory Turn-On Service: We offer a turn on service for a fee that will ensure the unit has been properly installed and the full warranty is in effect.  (Failures caused by incorrect installation are not covered by the warranty.)  If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.  This service is provided by factory engineers, not third party engineers. Pricing is dependent upon location, number of units, airfare rates, etc. Please contact us for more details if interested.
  • Customized EPO: This Emergency Power Off (EPO) Feature can be tailored to trip off current breakers or perform other inhibits per specific customer applications.
  • Shock and Vibration Mounts: A wide selection of mounts are available for compliance to MIL-S-901, MIL-STD-167, and other related standards.
  • Premium Wide-Temp Range VRLA batteries with up to 12 year life
  • Additional run time via external battery cabinets
  • Drip Shields for protection against falling or dripping liquids
  • AUX DC Outputs
  • 50/60 Hz Output Switch
  • Output Voltage Adjustment Knob +/-10%
  • Casters for Portability (22″ Wide Models Only)
  • Power Distribution Units (PDUs)
  • Environmental Stress Screening Services

IEC 62040-2 (for 220/380 VAC, 50 Hz Models except 320+ KVA)
EN50091-1
EN50091-2
FCC Class A

Jupiter-Series Models can be equipped with options to meet*:

MIL-STD-810 – for shock, vibration, humidity, and temperature
MIL-STD-167 – for vibration
MIL-STD-461 – for EMI
MIL-S-901 – for shock
MIL-STD-1399 – for shipboard power

*Compliance to these “designed to meet” standards based on similarity to previously qualified designs. Formal Qual Testing to these and other standards is available optionally.

Jupiter Series High Power True Online UPS Systems PDF Data Sheet