CGL Series 12 VDC Nominal 1.5 KW Pure Sine Wave DC-AC Inverters

  • Microprocessor based design with absolutely accurate and stable frequency.
  • Panel indicators for battery voltage & load level.
  • Compact and light weight, yet rugged and vehicle rated, 83-90% efficient.
  • Tightly regulated output voltage and frequency
  • Switch selectable 50 or 60 Hz output, all models
  • Capable of driving highly reactive loads such as electric tools and appliances.
  • Capable of driving highly capacitive loads such as switching power supplies.
  • Very low harmonic distortion, THD<3%.
  • Suitable for vehicle or wall mounting.
  • Standard inputs 10 -16VDC
  • Standard outputs 110V/60Hz, 230V/50Hz.
  • Switch selectable ±10V output change.
  • RS232 communication standard.
  • Below 1W consumption in sleep mode.
Compare Compare

Description

Legacy Series: This series is an older generation suitable for legacy military programs and other specialty applications. Nova Electric still services these models if required, but for new programs and most military / industrial / commercial applications, please see CGP or CGD series for a replacement.

Nova Electric’s CGL-Series 1500 Watt inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. These CGL-Series 1500 Watt inverters can also drive hand drills, motors and small compressors – please consult the factory for proper sizing. These CGL models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters. For more information on the Nova Electric CGL-Series 1500 Watt inverters, you may contact us for a free and comprehensive price quote.

Model Selection

MODELINPUT RANGE VDC OUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER APPROX. WEIGHT (LB) SIZE IN. (HXWXL)
CGL1.5K-12-120 10-16 VDC 12050 or 60 1.5 KW 15.5 4.13×10.75×15.26
MODELINPUT RANGE VDC OUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER APPROX. WEIGHT (LB) SIZE IN. (HXWXL)
CGL1.5K-12-220 10-16 VDC 22050 or 60 1.5 KW 15.5 4.13×10.75×15.26

EMI Conduction and Radiation|Compliance to FCC class A|Compliance to En55022 class A
EMS Immunity|-|Compliance to EN61000-3-2,3
LVD|-|Compliance to EN60950-1
e-MARK|-|Compliance to e-13*72/245/EEC, 95/54/EC

[button link=”https://novaelectric.com/pdf/RoHS-Conformity-2016.pdf” size=”medium”]Declaration of RoHS 2.0 Conformity[/button]

  • Input Voltage: 10-16 VDC
  • Output Voltage 110V model: 100/110/120 VAC
  • Output Voltage 220V model: 220/230/240 VAC
  • Output Frequency: 50 or 60 HZ User Selectable + 0.05% Accuracy
  • Continuous Power Rating:1500W/2000VA 
  • Surge Rating: 2000W/2500VA
  • Peak Output Current: 25 Amps 110V model / 11 Amps 230V model
  • Efficiency (full load): 110V model 83%
  • Efficiency (full load): 220V model 86%
  • No load Current: <1.0W Sleep Mode
  • Output Waveform Sinewave: <3% THD
  • Output Regulation: -10% / +4% All models
  • Protection: Overload, Short Circuit, Reverse Polarity (Fuse), O..T, Over/Under Input Voltage, Fan Failure
    RS-232 & Remote Control Standard on all models.
  • Safety: UL458 EN60950
  • EMC: FCC Class B, EN50081-1:1992, EN50082-1:1992, EN55022B:1994, EN61000-4-2:1995, EN6100-4-3:1996, ENV50204:1995 e-Mark e13-020932
  • Ambient Temperature: -20° to +50°C
  • Storage Temperature: -40°C to +71°C
  • Size: 4.13″H x 10.75″W x 15.26″L
  • Weight: 15.5lb

OPTIONAL FEATURES

  • 19″ Rack Mount Panel – Please click here for drawing.