NGL Series 155 VDC Nominal 100-1200 Watt Pure Sine Wave DC-AC Inverters

NGL Series 155 VDC Nominal 100-1200 Watt Pure Sine Wave DC-AC Inverters

  • Pure Sinewave Output
  • Compact Size
  • Lightweight design
  • Extremely Rugged Construction
  • High reliability: MTBF exceeds 100,000 hours
  • OV, O.L. and O.T. protected
  • MTTR below 30 minutes
  • Withstands highly reactive load
  • Tight voltage and frequency regulation
  • Conformal coated boards
Compare
  • Description
  • Models
  • Specifications

Description

Legacy Series: This series is an older generation suitable for legacy military programs and other specialty applications. For new programs and most military / industrial / commercial applications, please contact us for a quote on modern replacements.

Utilizing field proven technology, this family of rugged pure sinewave DC AC Inverters is suitable for harsh environments and can be customized for unique applications including:

  • Military programs, vehicular
  • Communications
  • Cellular sites
  • Shelters
  • SATCOM terminal
  • AC power from battery
  • HMMWV applications
  • TV & Radio vans
  • Shipboard applications
  • Rapid transit & Rail Applications
Partial Standard Product Listing
120-205 VDC Operating Input / 300 VA – 1.5 KVA
(Consult factory for higher power ratings)
60 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
NGL1260-155-120 12060120 VA / 100 W 2.5 2.7×4.5×7.8
NGL3060-155-120 12060300 VA / 240 W 63.25x5x13.75
NGL1K60-155-120 120601000 VA / 800 W 63.25x5x13.75
NGL1.5K60-155-120 120601500 VA / 1200 W 63.25x5x13.75
50 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
NGL1250-155-220 22050120 VA / 100 W 2.5 2.7×4.5×7.8
NGL3050-155-220 22050300 VA / 240 W 63.25x5x13.75
NGL1K50-155-220 220501000 VA / 800 W 63.25x5x13.75
NGL1.5K50-155-220 220501500 VA / 1200 W 63.25x5x13.75
400 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
NGL12400-155-115 115400120 VA / 100 W 2.5 2.7×4.5×7.8
NGL30400-155-115 115400300 VA / 240 W 63.25x5x13.75
NGL1K400-155-115 1154001000 VA / 800 W 63.25x5x13.75
NGL1.5K400-155-115 1154001500 VA / 1200 W 63.25x5x13.75

NGL- Model Number Selection Chart

ELECTRICAL
  • Input Voltage:See chart above
  • Output Voltage: See chart above
  • Frequency: 50 Hz, 60 Hz, 400 Hz (±0.5%)
  • Frequency Regulation: ±0.5% N.L. to F.L.
  • Voltage Regulation: ±1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Isolation: 1500 Volt
  • Approx. 3 cycle recovery to 95% of nominal
ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Std -30°C to +60°C Optional
  • Storage Temp: -40°C to +71°C
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A; can meet MIL-STD-461 with optional filtering
You've just added this product to the cart: