NGL Series 270 VDC Nominal Input Pure Sine Wave DC-AC Inverters

NGL Series 270 VDC Nominal Input Pure Sine Wave DC-AC Inverters

  • Pure Sinewave Output
  • Compact Size
  • Lightweight design
  • Extremely Rugged Construction
  • High reliability: MTBF exceeds 100,000 hours
  • OV, O.L. and O.T. protected
  • MTTR below 30 minutes
  • Withstands highly reactive load
  • Tight voltage and frequency regulation
  • Conformal coated boards
Compare

Description

These rugged inverters are extremely reliable, designed to provide many years of service in high shock, vibration, humidity, and EMI environments. Combining 3 inverters to form a 3 phase power system is optional. In this configuration, a 3 phase and neutral line is generated with precise synchronization. Utilizing field proven technology, this family of Pure Sinewave DC-AC inverters can be customized for unique applications including:

Applications

  • Shelters
  • Tactical Systems
  • Shipboard Power
  • HMMWVs
  • Mobile Systems
  • Ground Support
  • Aircraft

Compliance (by test or similarity)

  • MIL-STD-810
  • MIL-STD-1275(1)
  • MIL-STD-461(2)
  • MIL-STD-167
  • MIL-STD-704
  • MIL-S-901(3)

(1) May require additional external module.
(2) May require external EMI Filter.
(3) Requires external shock absorbers.

Partial Standard Product Listing

60 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
 
NGL1060-270 12060120 VA / 100 W 2.4 2.68×4.50×7.75 QUOTE
NGL1K60-270 120601.2 KVA / 1 KW 6.4 2.60×6.30×12.25 QUOTE
NGL2K60-270 120602.5 KVA / 2 KW 145.00×8.00×12.50 QUOTE
NGL3K60-270 120603.5 KVA / 3 KW 155.00×8.00×12.50 QUOTE
NGL3.5K60-270 120604.5 KVA / 3.5 KW 16.35.00×8.00×14.77 QUOTE
50 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
 
NGL1050-270 22050120 VA / 100 W 2.4 2.68×4.50×7.75 QUOTE
NGL1K50-270 220501.2 KVA / 1 KW 6.4 2.60×6.30×12.25 QUOTE
NGL2K50-270 220502.5 KVA / 2 KW 145.00×8.00×12.50 QUOTE
NGL3K50-270 220503.5 KVA / 3 KW 155.00×8.00×12.50 QUOTE
NGL3.5K50-270 220504.5 KVA / 3.5 KW 16.35.00×8.00×14.77 QUOTE
400 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
 
NGL10400-270 115400120 VA / 100 W 2.4 2.68×4.50×7.75 QUOTE
NGL1K400-270 1154001.2 KVA / 1 KW 6.4 2.60×6.30×12.25 QUOTE
NGL2K400-270 1154002.5 KVA / 2 KW 145.00×8.00×12.50 QUOTE
NGL3K400-270 1154003.5 KVA / 3 KW 155.00×8.00×12.50 QUOTE
NGL3.5K400-270 1154004.5 KVA / 3.5 KW 16.35.00×8.00×14.77 QUOTE
Partial Three Phase Model Selection - Lower and Higher Capacities Available - Consult Factory
3 PHASE MODELS OUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER APPROX. WEIGHT (LB) SIZE IN.(HXWXL) RACK PANEL HEIGHT IN. OPT/STD OUTLINE DRAWING PICTURE
 
NGL3K3/6-270 (120/208) 120/208 603KVA355.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL3K3/5-270 (220/380) 220/380 503KVA355.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL3K3/4-270 (115/200) 115/200 4003KVA355.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL4.5K3/6-270 (120/208) 120/208 604.5KVA605.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL4.5K3/5-270 (220/380) 220/380 504.5KVA605.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL4.5K3/4-270 (115/200) 115/200 4004.5KVA605.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL6K3/6-270 (120/208) 120/208 606KVA655.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL6K3/5-270 (220/380) 220/380 506KVA655.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL6K3/4-270 (115/200) 115/200 4006KVA655.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL9K3/6-270 (120/208) 120/208 609KVAC/F C/F C/F OPT/STD QUOTE
NGL9K3/5-270 (220/380) 220/380 509KVAC/F C/F C/F OPT/STD QUOTE
NGL9K3/4-270 (115/200) 115/200 4009KVAC/F C/F C/F OPT/STD QUOTE
ELECTRICAL
  • Input Voltage: 240-300 VDC
  • Output Voltage: See MODELS tab
  • Frequency: 50 Hz, 60 Hz, 400 Hz (±0.5%)
  • Frequency Regulation: ±0.5% N.L. to F.L.
  • Voltage Regulation: ±1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Isolation: 1500 Volt
  • Transient Response: Approx. 3 cycle recovery to 95% of nominal
ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Std -30°C to +60°C Optional
  • Storage Temp: -40°C to +71°C
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A; can meet MIL-STD-461 with optional filtering

OPTIONS

NGL Series Pure Sine Wave DC-AC Inverters PDF Data Sheet

You've just added this product to the cart: