CGP Series 2 KW Pure Sinewave COTS Inverters

  • Microprocessor based design with absolutely
    accurate and stable frequency.
  • Compact and light weight, yet rugged and
    vehicle rated.
  • Tightly regulated output voltage and frequency
  • Switch selectable 50 or 60 Hz output, all models
  • Capable of driving highly reactive loads such as
    electric tools and appliances.
  • Capable of driving highly capacitive loads such
    as switching power supplies.
  • Three color LED status indicator
  • Suitable for vehicle or wall mounting
  • Standard outputs 110V/60Hz, 230V/50Hz
  • Switch selectable ±10V output change
  • UL / e-13 / CE / FCC Approved
  • Temperature & load controlled cooling fan
Compare

Description

Nova Electric’s CGP-Series inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic load such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors – please consult the factory for proper sizing. These CGP models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters.

  • Input & Output fully isolated
  • Output protection: short circuit / overload / overtemperature
  • Output frequency 50/60 Hz selectable by dip switch

Applications:

  • Computers
  • Printers
  • Monitors
  • Sail Boats
  • Photo Voltaic
  • Electric Tools
  • Applicances
  • Instruments
  • RVs
CGP2K-12-120 CGP2K-24-120 CGP2K-48-120 CGP2K-12-220 CGP2K-24-220 CGP2K-48-220
No Load Power Consumption
On Mode @ Save Mode
On Mode @ No Load Mode
@12VDC
<0.1A
≤1.8A
@24VDC
<0.05A
≤1.0A
@48VDC
<0.05A
≤0.5A
@12VDC
<0.1A
≤1.8 A
@24VDC
<0.05A
≤1.0 A
@48VDC
<0.05A
≤0.5 A
Input Under – Voltage Protection 10.5 ± 0.3 VDC 21.0 ± 0.5 VDC 42.0 ± 1.0 VDC 10.5 ± 0.3 VDC 21.0 ± 0.5 VDC 42.0 ± 1.0 VDC
Input Under – Voltage Recovery 12.5 ± 0.3 VDC 25.0 ± 0.5 VDC 50.0 ± 1.0 VDC 12.5 ± 0.3 VDC 25.0 ± 0.5 VDC 50.0 ± 1.0 VDC
Input Over – Voltage Protection 16.5 ± 0.3 VDC 33.0 ± 0.5 VDC 66.0 ± 1.0 VDC 16.5 ± 0.3 VDC 33.0 ± 0.5 VDC 66.0 ± 1.0 VDC
Input Over – Voltage Recovery 14.5 ± 0.3 VDC 29.0 ± 0.5 VDC 58.0 ± 1.0 VDC 14.5 ± 0.3 VDC 29.0 ± 0.5 VDC 58.0 ± 1.0 VDC

Model Selection

INPUT VDC 120 V MODELS 50 HZ OR 60 HZ 220 V MODELS 50 HZ OR 60 HZ DIMENSIONS
(L” X W” X H”)[IN]
DIMENSIONS
(L” X W” X H”)[MM]
WEIGHT
10.5 – 16.5 V CGP2K-12-120 CGP2K-12-220 17.44 x 9.76 x 3.27 443 x 248 x 83 11.6 lbs [5.24 kg]
21 – 33 V CGP2K-24-120 CGP2K-24-220 14.65 x 7.87 x 3.27 372 x 200 x 83 11.6 lbs [5.24 kg]
42 – 66 V CGP2K-48-120 CGP2K-24-220 14.65 x 7.87 x 3.27 372 x 200 x 83 11.6 lbs [5.24 kg]

ELECTRICAL

      • Input Voltage: See Table
      • Output Voltage 110V model: 100/110/115/120 VAC
      • Output Voltage 220V model: 200/220/230/240 VAC
        Output Frequency:
        50 or 60 HZ ±0.5% Accuracy
      • Continuous Power Rating: 2000W/2000VA
      • Surge Rating: <3500VA (1 second)
      • Efficiency 110V model (full load): 92% – 94%
      • Efficiency 220V model (full load): 94% – 95%
      • Output Waveform Sinewave: <5% THD (120V)*
      • Output Waveform Sinewave: <3% THD (220V)**
      • Output Voltage Regulation: ±5% (120V), ±3% (220V)
      • Protection: Overload, Short Circuit, Reverse Polarity (Fuse), O.T, Over/Under Input Voltage

SAFETY & EMC

120V: UL458***; FCC Class A****

220V: EN60950-1; EN55022, EN55024; EN61000-3-2, -3-3; EN61000-4-2, 3, 4, 5, 6, 8, 11

E-MARK (220V): Certified CISPR 25; ISO7637-2

 

ENVIRONMENTAL

Operating Temp.: -20° to +40°; + 60°C @ 40% Load

Storage Temp. Range: -30° to +71°C

Humidity: To 95% non-condensing

Airflow: Intake (fans) to exhaust vents in chassis panels

NOTES

* Normal Condition: Vin=12.5V / 25V / 50V Vo=100 / 110 / 115 / 120 VAC 80% Full load (PF=1.0)
** Normal Condition: Vin=12.5V / 25V / 50V Vo=200 /220 / 230 / 240 VAC 80% Full load (PF=1.0)
*** UL-458 only for GFCI receptacles
**** Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

CGP Series 2 KW Pure Sinewave COTS Inverters PDF Data Sheet

CGP SERIES 2 KW PURE SINEWAVE COTS INVERTERS MOUNTING DIMENSIONS