army UPS system
Jupiter 43.5” Rugged UPS System cabinet with optional shock mounts shown
Jupiter Series

Rugged, 240 VDC, 10 KVA - 200 KVA

210-280 VDC Operating Input / Pure Sine-Wave Output

Typical Jupiter 22

(Typical Jupiter 22″ Wide Cabinet)

Nova’s Jupiter-Series DC-AC Inverters are high-reliability pure sinewave power sources specifically designed for demanding commercial, heavy industrial, and military applications.

They can be built to meet MIL-STD-810, MIL-STD-901, MIL-STD-461, and other standards optionally.

These models utilize the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications such as:

  • Submarine and Shipboard Power Systems
  • Aluminum Mills
  • Steel Mills
  • Cranes
  • Heavy Industry
  • Military Applications
  • Single Phase Output Models Available

210-280 VDC Operating Input / 10 KVA – 200 KVA
(Consult factory for higher power ratings)
Standard Model Selection
60 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
Model Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
J10K60-240 120 60 10KVA / 8KW 638 63x22x31.5 pdf_icon
J20K60-240 120 60 20KVA / 16KW 770 63x22x31.5 pdf_icon
J30K60-240 120 60 30KVA / 24KW 990 63x22x31.5 pdf_icon
J40K60-240 120 60 40KVA / 32KW 1210 63x22x31.5 pdf_icon
J50K60-240 120 60 50KVA / 40KW 1650 63×43.5×31.5 pdf_icon
J60K60-240 120 60 60KVA / 48KW 1870 63×43.5×31.5 pdf_icon
J80K60-240 120 60 80KVA / 64KW 2090 63x87x31.5 pdf_icon
J100K60-240 120 60 100KVA / 80KW 2420 63x87x31.5 pdf_icon
J120K60-240 120 60 120KVA / 96KW 3300 63x87x31.5 pdf_icon
J160K60-240 120 60 160KVA / 128KW 3960 63x87x31.5 pdf_icon
J200K60-240 120 60 200KVA / 160KW 4840 63x87x31.5 pdf_icon
50 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
Model Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
J10K50-240 (220) 220 50 10KVA / 8KW 638 63x22x31.5 pdf_icon
J20K50-240 (220) 220 50 20KVA / 16KW 770 63x22x31.5 pdf_icon
J30K50-240 (220) 220 50 30KVA / 24KW 990 63x22x31.5 pdf_icon
J40K50-240 (220) 220 50 40KVA / 32KW 1210 63x22x31.5 pdf_icon
J50K50-240 (220) 220 50 50KVA / 40KW 1650 63×43.5×31.5 pdf_icon
J60K50-240 (220) 220 50 60KVA / 48KW 1870 63×43.5×31.5 pdf_icon
J80K50-240 (220) 220 50 80KVA / 64KW 2090 63×43.5×31.5 pdf_icon
J100K50-240 (220) 220 50 100KVA / 80KW 2420 63×43.5×31.5 pdf_icon
J120K50-240 (220) 220 50 120KVA / 96KW 3300 63x87x31.5 pdf_icon
J160K50-240 (220) 220 50 160KVA / 128KW 3960 63x87x31.5 pdf_icon
J200K50-240 (220) 220 50 200KVA / 160KW 4840 63x87x31.5 pdf_icon
400 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
Model Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
J10K400-240 115 400 10KVA / 8KW 638 63x22x31.5 pdf_icon
J20K400-240 115 400 20KVA / 16KW 770 63x22x31.5 pdf_icon
J30K400-240 115 400 30KVA / 24KW 990 63x22x31.5 pdf_icon
J40K400-240 115 400 40KVA / 32KW 1210 63x22x31.5 pdf_icon
J50K400-240 115 400 50KVA / 40KW 1650 63×43.5×31.5 pdf_icon
J60K400-240 115 400 60KVA / 48KW 1870 63×43.5×31.5 pdf_icon
J80K400-240 115 400 80KVA / 64KW 2090 63×43.5×31.5 pdf_icon
J100K400-240 115 400 100KVA / 80KW 2420 63×43.5×31.5 pdf_icon
J120K400-240 115 400 120KVA / 96KW 3300 63x87x31.5 pdf_icon
J160K400-240 115 400 160KVA / 128KW 3960 63x87x31.5 pdf_icon
J200K400-240 115 400 200KVA / 160KW 4840 63x87x31.5 pdf_icon
3 Phase Models
3 Phase Model Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
J10K3/6-240 (120/208) 120/208 60 10KVA 638 63x22x31.5 pdf_icon
J10K3/5-240 (220/380) 220/380 50 10KVA 638 63x22x31.5 pdf_icon
J20K3/6-240 (120/208) 120/208 60 20KVA 770 63x22x31.5 pdf_icon
J20K3/5-240 (220/380) 220/380 50 20KVA 770 63x22x31.5 pdf_icon
J30K3/6-240 (120/208) 120/208 60 30KVA 990 63x22x31.5 pdf_icon
J30K3/5-240 (220/380) 220/380 50 30KVA 990 63x22x31.5 pdf_icon
J40K3/6-240 (120/208) 120/208 60 40KVA 1210 63x22x31.5 pdf_icon
J40K3/5-240 (220/380) 220/380 50 40KVA 1210 63x22x31.5 pdf_icon
J50K3/6-240 (120/208) 120/208 60 50KVA 1650 63×43.5×31.5 pdf_icon
J50K3/5-240 (220/380) 220/380 50 50KVA 1650 63×43.5×31.5 pdf_icon
J60K3/6-240 (120/208) 120/208 60 60KVA 1870 63×43.5×31.5 pdf_icon
J60K3/5-240 (220/380) 220/380 50 60KVA 1870 63×43.5×31.5 pdf_icon
J80K3/6-240 (120/208) 120/208 60 80KVA 2090 63×43.5×31.5 pdf_icon
J80K3/5-240 (220/380) 220/380 50 80KVA 2090 63×43.5×31.5 pdf_icon
J100K3/6-240 (120/208) 120/208 60 100KVA 2420 63×43.5×31.5 pdf_icon
J100K3/5-240 (220/380) 220/380 50 100KVA 2420 63×43.5×31.5 pdf_icon
J120K3/6-240 (120/208) 120/208 60 120KVA 3300 63x87x31.5 pdf_icon
J120K3/5-240 (220/380) 220/380 50 120KVA 3300 63x87x31.5 pdf_icon
J160K3/6-240 (120/208) 120/208 60 160KVA 3960 63x87x31.5 pdf_icon
J160K3/5-240 (220/380) 220/380 50 160KVA 3960 63x87x31.5 pdf_icon
J200K3/6-240 (120/208) 120/208 60 200KVA 4840 63x87x31.5 pdf_icon
J200K3/5-240 (220/380) 220/380 50 200KVA 4840 63x87x31.5 pdf_icon

 STANDARD FEATURES

  • • Complete input to output ‘Galvanic’ isolation.
  • • High frequency almost silent operation
  • • Push button starting and stopping
  • • Diagnostic panel with LCD and LED display
  • • Soft start on inverter
  • •Overload & and short circuit protection on charger and inverter
  • • True on-line Operation
  • • Optional Solid state transfer switch built in
  • • Optional Maintenance bypass switch built in
  • • All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance
  • • FCC class A approved
  • • Remote isolated dry relay contacts
  • • Available options to meet military specs, including MIL-STD-461, MIL-STD-167, MIL-STD-810

 MONITORING FEATURES

  • The Inverter includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor in real time the three phase information related to the UPS output and any abnormal conditions that have occurred. Standard commercially available software is provided. The RS232 Feature is included at no additional charge

 FRONT PANEL LCD DISPLAY AND LED INDICATORS

  • This will report all Inverter parameters. These includes input and output voltages, currents, frequency, DC voltage and current, as well as many other functions.

 LCD DISPLAY

  • Real time status, data, and historical events are displayed via the LCD display. The Inverter parameters, real time clock, and buzzer alarm also can be set through this LCD. The LCD is backlit by LEDs for easy visuals.

 STATUS LEDs

A series of LEDs representing all the important information of the Inverter provide information to the user. These LEDs are especially important when abnormal conditions occur. LED descriptions are as follows:

  • INVERTER ON – Inverter is running normally.
  • INVERTER SS – Inverter static switch is on while the reserve static switch is opened (off).
  • SHORT CIRCUIT – Inverter output is in short circuit state.
  • FUSE / OVERTEMP SD – Inverter has shut down due to either open fuse open or over temperature.
  • INVERTER FAIL SHUTDOWN – Inverter has shut down due to low inverter AC output.
  • BYPASS ON SHUTDOWN – Inverter shut down due closed bypass breaker (while inverter running).
  • HIGH DC SHUTDOWN – Inverter shut down due to high DC bus.
  • OVERLOAD SHUTDOWN – Inverter shutdown due to overload of the inverter for a period greater than the inverter can accept. The inverter will start after 7 seconds.
    70% LOAD – load connected to the output is over 70% of the Inverter rating.
    110% LOAD – load connected to the output is over 110% oh the Inverter rating.
    125% LOAD – load connected to the output is over 125% of the Inverter rating.
    150% LOAD – load connected to the output is over 150% of the Inverter rating.
  • RESERVE AC FAIL – reserve AC magnitude is out of range.
  • RESERVE FREQ FAIL – reserve frequency is out of range.
  • BATTERY LOW – DC bus (or battery) is lower than specified range, low battery shutdown will occur soon.
  • BATTERY LOW SHUTDOWN – inverter shutdown due to DC bus (or battery) lower than the acceptable DC voltage of the inverter.
  • HIGH DC – DC voltage over the acceptable DC voltage of the inverter.
  • EMERGENCY STOP – Inverter shut down activated by emergency stop switch.
  • DATA LINE – Blink when data is transmitted to or received from the communication port

 OTHER OPTIONS

  • CASTERS & LEVELERS
    For portability, the 22″ wide Jupiter cabinets may be optionally equipped with the base-mounted caster / leveler set as shown here.
  • DC INPUT BREAKER OPTION
    The optional DC Input breaker disconnect is offered to provide protection for the input.
  • SHOCK MOUNT OPTION
    The cabinet can be shock mounted, using optional rubber on coil type isolators. This will be enable the unit to withstand shock levels as specified in MIL-STD-901
  • RUGGEDIZING OPTION
    This option will add conformal coating and other additional internal structural members to allow the unit to meet many portions of MIL-STD-810.
  • TURN ON SERVICE OPTION
    We offer a turn on service that will ensure the Inverter has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.
  • SPARE PARTS KIT OPTION
    We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order then if they are ordered later on.

 WARNING LEDs

When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are:

  • RESERVE FAIL – Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range.
  • FUSE/TEMP – Either inverter fuse is open or over temperature has occurred.
  • OVERLOAD – Output is overloaded by over 110%, 125% or 150%
  • HIGH DC – This LED will light when DC input approaches high-line limit.
  • BAT LOW – This LED will light when the DC voltage is low.
  • BAT LOW STOP – This LED will light when the DC voltage is lower than specified range.
  • FAULT – The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop.

Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door.

 AUDIBLE ALARM

The audible alarm will beep under either one of the following conditions:

  • INVERTER IS OVERLOADED
    > 110% beep once every 3 seconds
    > 125% beep once every second
    > 150% beep twice every second
  • INVERTER IS SHORT CIRCUITED – Beeps continuously
  • FUSE OPEN– Beeps continuously
  • HEAT SINK OVER TEMPERATURE – Beeps continuously
  • HIGH DC SHUTDOWN – Beeps continuously
  • BYPASS ON STOP – Beeps continuously
  • EMERGENCY ON STOP – Beeps continuously
    The buzzer will also beep once every time the inverter is switched on or off to acknowledge to the user that his key entry is valid and accepted.temperature, bypass breaker on emergency stop.

Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door.

 COMMUNICATIONS OPTIONS

We offer options for communications with this Inverter series. Some popular options available at additional cost include the following:

  • UPSCAN: This is a hand held remote display and control module with LCD and LED display that can monitor via RS-485 UP to 99 UPS Units at a remote distance of up to 3,000 feet.
  • UPSCALL: This is a modem that will automatically dial out to a specified number when an abnormal situation occurs.
  • NETAGENT: This provides capability to monitor the Inverter over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided by MEGATEC at additional cost.

Specifications for the Nova Jupiter 3 Phase Inverter Series
PHASE 3-Phase Input/ 3-Phase Output
KVA 10 20 30 40 50 60 80 100 120 160 200
INVERTER
Output Voltage (VAC) Please Specify |120/208 |220/380 |230/400 |240/415 |277/480 |120 delta|220 3 ph delta |240 3 ph delta |380 3 ph delta |480 3 ph delta
Wave Form Sinewave
Output Power Factor 0.7 lead to 0.7 lag
Frequency Lock Range 50 / 60 Hz + 0.1 Hz (crystal controlled)
Output Frequency (free running) 60Hz or 50Hz (please specify)
Phase Shift Under 100% Unbalanced Load <0.5%
THD (Linear Load) 2% typical 3% max
OVERLOAD
<110% Continuous
110-125% Up to 15 minutes
125-150% Up to 10 minutes
>150% Up to 1 minute
Efficiency (100% Load) 90% 90.5% 90% 91%
STATIC SWITCH (optional)
Voltage Range Same as AC output. (Different voltages are available upon request)
Mains <-> Inverter 0 ms (True Online)
BTU/h @ Full Load (Approx, Max) 2.4K 4.8K 6.5K 8.9K 10.3K 12K 16K 19K 22K 30K 45K
Audible Noise <65 dBA (at 1m) <67 dBA (at 1m)
Temperature 0-50ºC (32-122ºF) (Other ranges available)
Humidity 0%-95% (Non-condensing)
Altitude Up to 1500 m Above Sea Level
EN50091-1, -2 Yes
Short Circuit Protection Yes
Lightning / EMC Filter MOV / Input & Output ( FCC CLASS A)
Galvanic Isolation Input and Output True Galvanic Isolation
LED, LCD, Audible Alarm Yes
Remote Control / Communication Interface Monitoring 1~99 Units simultaneously / Dry Contact, RS-232, RS-485 (Optional)
The appearance of U.S. Department of Defense (DoD) visual information does not imply or constitute DoD endorsement.