1 – 2 KVA Aircraft Galaxy Series True Online UPS

This Aircraft Galaxy Series rugged, military UPS system is specifically designed for airborne applications. This rugged UPS system has a three-phase input of 115/200 VAC, 400 Hz and a pure sinewave output of 120 VAC, 60Hz Single- Phase. This rugged, military UPS model contains all the features standard on other Galaxy Series units, as well as additional features that make it ideal for aircraft applications, including additional ruggedization, an internal EMI reduction package, and premium long life batteries.

Partial Model Selection

Model KVA Input Output UPS (Lbs) Run Time
GRSL11-1K60-115/200-120 1 115/200 VAC 120 VAC 110 15 min.
GRSL11-1.5K60-115/200-120 1.5 115/200 VAC 120 VAC 120 10 min.
GRSL11-2K60-115/200-120 2 115/200 VAC 120 VAC 130 5 min.

 AVAILABLE OPTIONS

  • • Single-Phase Input
  • • EPO Circuit
  • • MS Connector Mates
  • • Chassis Slides
  • • True RS-232 Interface Port
  • • Run Time to 24+ Hours
  • • Custom Cabinets & Turnkey Solutions
  • • SNMP

 SPECIFICATIONS

 ELECTRICAL
  • Frequency: Specify 50, 60, or 400Hz
  • Voltage Regulation: ± 1% NL to FL
  • Frequency Regulation: ± 0.5% NL to FL
  • Harmonic Distortion: 5% THD
  • Load Power Factor: 0.7 lead to 0.7 lag
  • Efficiency at full load: 75-80% typical
  • Overload: 125% for 5 minutes
 ENVIRONMENTAL & MECHANICAL
  • Operating Temp.: -20° to +50°C
  • Storage Temp. Range: -40° to +60°C
  • Humidity: to 95% non-condensing
  • Elevation: 15,000 Ft. (4,572m) operating;
    40,000 ft. (12.192m) non-operating
  • Shock/Vibration: per MIL-STD-810
  • Audible Noise: Less than 55 dbA at 5 ft.
  • EMI: per MIL-STD-461
 ALARM AND DIAGNOSTICS
  • System Status (Green/Red)
  • Utility Off (Red)
  • UPS Overload (Red)
  • UPS Off (Red)
  • Over Temp. (Red)
  • Low Battery (Red)
  • Load On Utility (Red)
  • Logic Fault (Red) (with SST Option)
  • Alarm Contacts: Standard
  • RS 232: Optional
  • SNMP: Optional
 INTERNAL BATTERIES
  • Premium 8-10 year life wide temp batteries which are sealed, maintenance- free, and user replaceable.
 PROTECTIVE FEATURES
  • AC & DC Input Circuit Breakers
  • Low Battery Shut Off
  • Overload & Thermal Protected
  • Input Under / Overvoltage Protected
  • Audible Alarm with Silence Switch
The appearance of U.S. Department of Defense (DoD) visual information does not imply or constitute DoD endorsement.