Jupiter Series 10-100 KVA 120 VDC Pure Sine Wave DC-AC Inverters

  • Complete input to output Galvanic Isolation.
  • High frequency (almost silent) operation
  • Push button starting and stopping
  • Diagnostic panel with LCD and LED display
  • Soft start on inverter
  • Overload & and short circuit protection
  • Optional Solid state transfer switch built in
  • Optional Maintenance bypass switch built in
  • All electronics are built in modular front-access cabinets and have front removable subassemblies for easy service and maintenance
  • FCC class A approved
  • Remote isolated dry relay contacts
  • Available options to meet military specs, including MIL-STD-461, MIL-STD-167, MIL-STD-810
Compare

Description

Nova’s Jupiter-Series Pure Sine Wave DC-AC Inverters are high-reliability power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally. These models utilize state of the art technology and the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications.

Typical applications include:

  • Military: UAV, Shipboard, Submarine, Aircraft, Mobile Power Units, Shelters
  • Utility Stations
  • Rail and Trolley Applications – 25, 91.66, 100, 200, and 250 Hz. available
  • Shore Power
  • Communications Systems
  • Cellular Sites

 

105-150 VDC Operating Input / 10 KVA – 50 KVA
(Consult factory for higher power ratings)
Standard Model Selection

60 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

MODELOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K60-120 1206010KVA / 8KW 77063x22x31.5 QUOTE
J15K60-120 1206015KVA / 12KW 88063x22x31.5 QUOTE
J20K60-120 1206020KVA / 16KW 88063x22x31.5 QUOTE
J30K60-120 1206030KVA / 24KW 165063×43.5×31.5 QUOTE
J40K60-120 1206040KVA / 32KW 176063×43.5×31.5 QUOTE
J50K60-120 1206050KVA / 40KW 187063×43.5×31.5 QUOTE
J60K60-120 1206060KVA / 48KW 242063x87x31.5 QUOTE
J80K60-120 1206080KVA / 64KW 308063x87x31.5 QUOTE
J100K60-120 12060100KVA / 80KW 352063x87x31.5 QUOTE

50 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
MODELOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K60-120 (220) 220 50 10KVA / 8KW 77063x22x31.5 QUOTE
J15K60-120 (220) 220 50 15KVA / 12KW 88063x22x31.5 QUOTE
J20K60-120 (220) 220 50 20KVA / 16KW 88063x22x31.5 QUOTE
J30K60-120 (220) 220 50 30KVA / 24KW 165063×43.5×31.5 QUOTE
J40K60-120 (220) 220 50 40KVA / 32KW 176063×43.5×31.5 QUOTE
J50K60-120 (220) 220 50 50KVA / 40KW 187063×43.5×31.5 QUOTE
J60K60-120 (220) 220 50 60KVA / 48KW 242063x87x31.5 QUOTE
J80K60-120 (220) 220 50 80KVA / 64KW 308063x87x31.5 QUOTE
J100K60-120 (220) 220 50 100KVA / 80KW 352063x87x31.5 QUOTE

400 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
MODELOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K400-120 220 50 10KVA / 8KW 77063x22x31.5 QUOTE
J15K400-120 220 50 15KVA / 12KW 88063x22x31.5 QUOTE
J20K400-120220 50 20KVA / 16KW 88063x22x31.5 QUOTE
J30K400-120 220 50 30KVA / 24KW 165063×43.5×31.5 QUOTE
J40K400-120 220 50 40KVA / 32KW 176063×43.5×31.5 QUOTE
J50K400-120 220 50 50KVA / 40KW 187063×43.5×31.5 QUOTE
J60K400-120 220 50 60KVA / 48KW 242063x87x31.5 QUOTE
J80K400-120 220 50 80KVA / 64KW 308063x87x31.5 QUOTE
J100K400-120 220 50 100KVA / 80KW 352063x87x31.5 QUOTE

50 60, 400 Hz 3 Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
3 PHASE MODEL OUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K3/6-120 (120/208) 120/208 6010KVA / 8KW 77063x22x31.5 QUOTE
J10K3/5-120 (220/380) 220/380 50 10KVA / 8KW 77063x22x31.5 QUOTE
J10K3/4-120 (115/200) 115/200 40010KVA / 8KW 77063x22x31.5 QUOTE
J20K3/6-120 (120/208) 120/208 6020KVA / 16KW 88063x22x31.5 QUOTE
J20K3/5-120 (220/380) 220/380 50 20KVA / 16KW 88063x22x31.5 QUOTE
J20K3/4-120 (115/200) 115/200 40020KVA / 16KW 88063x22x31.5 QUOTE
J30K3/6-120 (120/208) 120/208 6030KVA / 24KW 165063×43.5×31.5 QUOTE
J30K3/5-120 (220/380) 220/380 50 30KVA / 24KW 165063×43.5×31.5 QUOTE
J30K3/4-120 (115/200) 115/200 40030KVA / 24KW 165063×43.5×31.5 QUOTE
J40K3/6-120 (120/208) 120/208 60 40KVA / 32KW 176063×43.5×31.5 QUOTE
J40K3/5-120 (220/380) 220/380 50 40KVA / 32KW 176063×43.5×31.5 QUOTE
J40K3/4-120 (115/200) 115/200 40040KVA / 32KW 176063×43.5×31.5 QUOTE
J50K3/6-120 (120/208) 120/208 6050KVA / 40KW 187063×43.5×31.5 QUOTE
J50K3/5-120 (220/380) 220/380 50 50KVA / 40KW 187063×43.5×31.5 QUOTE
J50K3/4-120 (115/200) 115/200 40050KVA / 40KW 187063×43.5×31.5 QUOTE
J60K3/6-120 (120/208) 120/208 6060KVA / 48KW 242063x87x31.5 QUOTE
J60K3/5-120 (220/380) 220/380 50 60KVA / 48KW 242063x87x31.5 QUOTE
J60K3/4-120 (115/200) 115/200 40060KVA / 48KW 242063x87x31.5 QUOTE
J80K3/6-120 (120/208) 120/208 6080KVA / 64KW 308063x87x31.5 QUOTE
J80K3/5-120 (220/380) 220/380 50 80KVA / 64KW 308063x87x31.5 QUOTE
J80K3/4-120 (115/200) 115/200 40080KVA / 64KW 308063x87x31.5 QUOTE
J100K3/6-120 (120/208) 120/208 60100KVA / 80KW 3520 63x87x31.5 QUOTE
J100K3/5-120 (220/380) 220/380 50 100KVA / 80KW 3520 63x87x31.5 QUOTE
J100K3/4-120 (115/200) 115/200 400100KVA / 80KW 3520 63x87x31.5 QUOTE

Specifications for the Nova Electric Jupiter Series DC-AC Inverters
105-150 VDC Input (Extended Range Available) / Single or Three Phase Pure Sine Wave VAC Output
Output Voltage (VAC) Please Specify:
Three Phase WYE 115/200 | 120/208 | 220/380 | 230/400 | 240/415 | 277/480
Three Phase DELTA 120 3 ph delta |220 3 ph delta | 240 3 ph delta | 380 3 ph delta | 480 3 ph delta
Single Phase 120 1 ph | 220 1 ph | 240 1 ph | 480 1 ph
Other Voltages Available Optionally
Wave Form Sinewave
Output Power Factor 0.7 lead to 0.7 lag
Frequency Lock Range 50 / 60 Hz + 0.1 Hz (crystal controlled)
Output Frequency (free running) 50 / 60 / 400 Hz (please specify)
Phase Shift Under 100% Unbalanced Load <0.5%
THD (Linear Load) 2% typical 3% max
Overload
<110% Continuous
>110-125% Up to 15 minutes
>125-150% Up to 5 minutes
>150-170% Up to 30 seconds
>170-200% Up to 15 seconds
Efficiency (100% Load) 89%
STATIC SWITCH (optional)
Voltage Range Same as AC output. (Different voltages are available upon request)
Mains <-> Inverter 0 ms (True Online)
Audible Noise < 65dBA (at 1m)
Temperature 0-50ºC (32-122ºF) (Other ranges available)
Humidity 0%-95% (Non-condensing)
Altitude Up to 1500 m Above Sea Level
EN50091-1, -2 Yes
Short Circuit Protection Yes
Lightning / EMC Filter MOV / Input & Output ( FCC CLASS A)
Galvanic Isolation Output True Galvanic Isolation
LED, LCD, Audible Alarm Yes
Remote Control and Communication Interface Choices Dry Contact, RS-232, RS-485 (Optional,) UPScan Monitoring 1~99 Units Simultaneously (Optional,) Netagent (Optional,) MODBUS (Optional)

OPTIONS

    • Ruggedization: Ruggedization is highly recommended for harsh environment applications, and includes conformal coating of the Inverter’s PCBs to protect against humidity, condensation, and fungus growth. This option does not affect size or weight. For military applications, we offer more structural ruggedization, as well as shock mounts, to comply with such standards as MIL-S-901, MIL-STD-810, and other demanding MIL-Specs.
    • UPScan Remote Monitor Panel: This is a hand held remote display and control module with LCD and LED display that can monitor up to 99 Inverters at a remote distance of up to 3,000 feet via RS-485.
    • NETAGENT:  This provides capability to monitor the Inverter over the internet.  It includes the appropriate additional SNMP card and microprocessor.  When equipped with this option, the user can connect a CAT-5 cable for interface to the external LAN.
    • Complete Spare Parts Package: We offer a comprehensive spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans.  These spare parts kits are priced lower when ordered with the initial order then if they are ordered later on.
    • Factory Turn-On Service: We offer a turn on service for a fee that will ensure the unit has been properly installed and the full warranty is in effect.  (Failures caused by incorrect installation are not covered by the warranty.)  If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.  This service is provided by factory engineers, not third party engineers. Pricing is dependent upon location, number of units, airfare rates, etc. Please contact us for more details if interested.
    • Internal Solid-State Static Transfer Switch
    • AUX DC Outputs
    • Casters for Portability (22″ Wide Models Only)
    • Power Distribution Units (PDUs)
    • Environmental Stress Screening Services

Jupiter-Series Models can be equipped with options to meet*:

MIL-STD-810 – for shock, vibration, humidity, and temperature
MIL-STD-167 – for vibration
MIL-STD-461 – for EMI
MIL-S-901 – for shock

*Compliance to these “designed to meet” standards based on similarity to previously qualified designs. Formal Qual Testing to these and other standards is available optionally.

Jupiter Series High Power Pure Sine Wave DC-AC Inverters PDF Data Sheet