NGL Series 270 VDC Nominal Input Pure Sine Wave DC-AC Inverters

  • Pure Sinewave Output
  • Compact Size
  • Lightweight design
  • Extremely Rugged Construction
  • High reliability: MTBF exceeds 100,000 hours
  • OV, O.L. and O.T. protected
  • MTTR below 30 minutes
  • Withstands highly reactive load
  • Tight voltage and frequency regulation
  • Conformal coated boards
Compare

Description

These rugged inverters are extremely reliable, designed to provide many years of service in high shock, vibration, humidity, and EMI environments. Combining 3 inverters to form a 3 phase power system is optional. In this configuration, a 3 phase and neutral line is generated with precise synchronization. Utilizing field proven technology, this family of Pure Sinewave DC-AC inverters can be customized for unique applications including:

Applications

  • Shelters
  • Tactical Systems
  • Shipboard Power
  • HMMWVs
  • Mobile Systems
  • Ground Support
  • Aircraft

Compliance (by test or similarity)

  • MIL-STD-810
  • MIL-STD-1275(1)
  • MIL-STD-461(2)
  • MIL-STD-167
  • MIL-STD-704
  • MIL-S-901(3)

(1) May require additional external module.
(2) May require external EMI Filter.
(3) Requires external shock absorbers.

Partial Standard Product Listing
240-300 VDC Operating Input / 100 W – 3.5 KW
(Consult factory for higher power ratings)

60 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
NGL1060-270 12060120 VA / 100 W 2.4 2.68×4.50×7.75 QUOTE
NGL1K60-270 120601.2 KVA / 1 KW 6.4 2.60×5.00×10.00 QUOTE
NGL2K60-270 120602.5 KVA / 2 KW 145.00×8.00×12.50 QUOTE
NGL3K60-270 120603.5 KVA / 3 KW 155.00×8.00×12.50 QUOTE
NGL3.5K60-270 120604.5 KVA / 3.5 KW 16.35.00×8.00×14.77 QUOTE
50 Hz Models
MODELSOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
NGL1050-270(220) 22050120 VA / 100 W 2.4 2.68×4.50×7.75 QUOTE
NGL1K50-270(220) 220501.2 KVA / 1 KW 6.4 2.60×5.00×10.00 QUOTE
NGL2K50-270(220) 220502.5 KVA / 2 KW 145.00×8.00×12.50 QUOTE
NGL3K50-270(220) 220503.5 KVA / 3 KW 155.00×8.00×12.50 QUOTE
NGL3.5K50-270(220) 220504.5 KVA / 3.5 KW 16.35.00×8.00×14.77 QUOTE
Partial Three Phase Model Selection - Lower and Higher Capacities Available - Consult Factory
3 PHASE MODELS OUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER APPROX. WEIGHT (LB) SIZE IN.(HXWXL) RACK PANEL HEIGHT IN. OPT/STD OUTLINE DRAWING PICTURE
NGL3K3/6-270 (120/208) 120/208 603KVA355.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL3K3/5-270 (220/380) 220/380 503KVA355.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL3K3/4-270 (115/200) 115/200 4003KVA355.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL4.5K3/6-270 (120/208) 120/208 604.5KVA605.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL4.5K3/5-270 (220/380) 220/380 504.5KVA605.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL4.5K3/4-270 (115/200) 115/200 4004.5KVA605.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL6K3/6-270 (120/208) 120/208 606KVA655.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL6K3/5-270 (220/380) 220/380 506KVA655.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL6K3/4-270 (115/200) 115/200 4006KVA655.25x19x22 5.25 STDGL3K3/6-24 (120/208) QUOTE
NGL9K3/6-270 (120/208) 120/208 609KVAC/F C/F C/F OPT/STD QUOTE
NGL9K3/5-270 (220/380) 220/380 509KVAC/F C/F C/F OPT/STD QUOTE
NGL9K3/4-270 (115/200) 115/200 4009KVAC/F C/F C/F OPT/STD QUOTE
ELECTRICAL
  • Input Voltage: 240-300 VDC
  • Output Voltage: See MODELS tab
  • Frequency: 50 Hz, 60 Hz, 400 Hz (±0.5%)
  • Frequency Regulation: ±0.5% N.L. to F.L.
  • Voltage Regulation: ±1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Isolation: 1500 Volt
  • Transient Response: Approx. 3 cycle recovery to 95% of nominal
ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Std / -40°C to +60°C Optional
  • Storage Temp: -40°C to +71°C
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A; can meet MIL-STD-461 with optional filtering

OPTIONS

NGL Series Pure Sine Wave DC-AC Inverters PDF Data Sheet