Galaxy Series 240 VDC Nominal Input Pure Sine Wave DC-AC Inverters

Galaxy Series 240 VDC Nominal Input Pure Sine Wave DC-AC Inverters

  • Pure Sinewave Output
  • Small Size
  • Lightweight, extremely compact
  • High reliability, MTBF exceeds 100,000 hours
  • OV, O.L. and O.T. protected
  • MTTR below 30 minutes; modular design
  • Withstands high reactive load
  • Tight voltage and frequency regulation
  • Output fault alarm (relay enclosure)
  • Boards are conformal coated
Compare
  • Description
  • Models
  • Specifications
  • Popular Options
  • Data Sheets

Description

The transformer isolated Galaxy Series inverters are designed for harsh environment, military, and steel mill applications, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with these types of conditions. These rugged inverters are extremely reliable, designed to provide many years of service in high shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of Pure Sinewave DC-AC inverters can be customized for unique applications including:

  • Submarine and Shipboard Power Systems
  • Aluminum Mills
  • Steel Mills
  • Cranes
  • Heavy Industry
  • Military Applications
Partial Standard Model Selection
(Consult factory for higher power ratings)
60 Hz Models
60 Hz Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Approx. Efficiency Outline Drawing
GH5060-240 120 60 500VA 90 24×20.75×7.15 88% pdf_icon GH5060-240
GH1K60-240 120 60 1KVA 95 24×20.75×7.15 88% pdf_icon GH1K60-240
GH2K60-240 120 60 2KVA 130 30x24x8 88% pdf_icon GH2K60-240
GH3K60-240 120 60 3KVA 170 30x24x8 88% pdf_icon
GH5K60-240 120 60 5KVA 200 30x24x8 88% pdf_icon
GH7.5K60-240 120 60 7.5KVA 200 36x24x16 88% pdf_icon
GH10K60-240 120 60 10KVA 260 36x24x16 88% pdf_icon
GH15K60-240 120 60 15KVA 350 42x30x21.2 88%
GH20K60-240 120 60 20KVA 550 54x36x16 88% pdf_icon
GH25K60-240 120 60 25KVA 700 54x36x16 88% pdf_icon
GH30K60-240 120 60 30KVA 900 60x48x16 C/F pdf_icon
GH35K60-240 120 60 35KVA 1100 60x48x16 C/F pdf_icon
50 Hz Models
50 Hz Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Approx. Efficiency Outline Drawing
GH5050-240(220) 220 50 500VA 90 24×20.75×7.15 88% pdf_icon GH5050-240(220)
GH1K50-240(220) 220 50 1KVA 95 24×20.75×7.15 88% pdf_icon GH1K50-240(220)
GH2K50-240(220) 220 50 2KVA 130 30x24x8 88% pdf_icon GH2K50-240(220)
GH3K50-240(220) 220 50 3KVA 170 30x24x8 88% pdf_icon
GH5K50-240(220) 220 50 5KVA 200 30x24x8 88% pdf_icon
GH7.5K50-240(220) 220 50 7.5KVA 200 36x24x16 88% pdf_icon
GH10K50-240(220) 220 50 10KVA 260 36x24x16 88% pdf_icon
GH15K50-240(220) 220 50 15KVA 350 42x30x21.2 88%
GH20K50-240(220) 220 50 20KVA 550 54x36x16 88%
GH25K50-240(220) 220 50 25KVA 700 54x36x16 88% pdf_icon
GH30K50-240(220) 220 50 30KVA 900 54x36x16 C/F pdf_icon
GH35K50-240(220) 220 50 35KVA 1100 54x36x16 C/F pdf_icon
50/60/400 Hz Models 3 Phase Output
Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Approx. Efficiency Outline Drawing
GH1.5K3/5-240 220/380 50 1.5KVA 150 24×20.75×7.15 88% pdf_icon
GH1.5K3/6-240 120/208 60 1.5KVA 150 24×20.75×7.15 88% pdf_icon
GH1.5K3/4-240 115/200 400 1.5KVA 120 24×20.75×7.15 88% pdf_icon
GH3K3/5-240 220/380 50 3KVA 180 30x24x12 88% pdf_icon
GH3K3/6-240 120/208 60 3KVA 160 30x24x12 88% pdf_icon
GH3K3/4-240 115/200 400 3KVA 140 30x24x12 88% pdf_icon
GH6K3/5-240 220/380 50 6KVA 220 36x24x16 88% pdf_icon
GH6K3/6-240 120/208 60 6KVA 200 36x24x16 88% pdf_icon
GH6K3/4-240 115/200 400 6KVA 180 36x24x16 88% pdf_icon
GH7.5K3/5-240 220/380 50 7.5KVA 260 36x24x16 88% pdf_icon
GH7.5K3/6-240 120/208 60 7.5KVA 240 36x24x16 88% pdf_icon
GH15K3/5-240 220/380 50 15KVA C/F C/F 88%
GH15K3/6-240 120/208 60 15KVA C/F C/F 88%
GH15K3/4-240 115/200 400 15KVA C/F C/F 88%
GH30K3/5-240 220/380 50 30KVA C/F 54x36x16 88% pdf_icon
GH30K3/6-240 120/208 60 30KVA C/F 54x36x16 88% pdf_icon
GH30K3/4-240 115/200 400 30KVA C/F 54x36x16 88% pdf_icon
ELECTRICAL
  • Input Voltage: 210 – 280 VDC (Extended range available)
  • Output Voltage: See Table
  • Frequency: 50 Hz, 60 Hz, 400 Hz (+/-0.5%)
  • Frequency Regulation: +/-0.5% N.L. to F.L.
  • Voltage Regulation: +/-1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Sync & Phase Lock Range: +/-3 Hz, Typical (50/60 Hz models)
  • Transient Response: Approx. 1/4 cycle recovery to 95% of nominal
ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Standard -40°C to +71°C Optional
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A, Can meet MIL-STD-461 with additional filtering

OPTIONS

  • Ruggedization against high shock, vibration and humidity
  • MS connector mates
  • Multiple output outlets
  • Chassis Slide Guides
  • Electromechanical transfer switch
  • Custom enclosures
  • 3Ø Power Input
  • Premium Wide-Temp Range VRLA batteries with up to 12 year life
  • “LIFE” models feature internal Lithium Iron Phosphate batteries with embedded Battery Management System for substantial weight savings and longer run time.
  • Additional run time via external batteries
  • 400 Hz input and / or output
  • CAD Free Connectors
  • Non-PVC wiring
  • 28 VDC Input
  • High IP Protection for front / rear panels (typically IP32,) including louvers on all intake and exhaust, as well as fully gasketed breakers, switches, and indicators.
  • AUX DC Outputs
  • RTCA/DO-160G Compliant Aircraft Grade Package
  • Power Distribution Units (PDUs)
  • Environmental Stress Screening Services

Galaxy Series 240 VDC Nominal Input Pure Sine Wave DC-AC Inverters PDF Data Sheet

You've just added this product to the cart: