NGL Series 120 VDC Nominal Input Pure Sine Wave DC-AC Inverters

NGL Series 120 VDC Nominal Input Pure Sine Wave DC-AC Inverters

  • Pure Sinewave Output
  • Compact Size
  • Lightweight design
  • Extremely Rugged Construction
  • High reliability: MTBF exceeds 100,000 hours
  • OV, O.L. and O.T. protected
  • MTTR below 30 minutes
  • Withstands highly reactive load
  • Tight voltage and frequency regulation
  • Conformal coated boards
Compare
  • Description
  • Models
  • Specifications
  • Popular Options
  • Data Sheets

Description

These rugged inverters are extremely reliable, designed to provide many years of service in high shock, vibration, humidity, and EMI environments. Combining 3 inverters to form a 3 phase power system is optional. In this configuration, a 3 phase and neutral line is generated with precise synchronization. Utilizing field proven technology, this family of Pure Sinewave DC-AC inverters can be customized for unique applications including:

Applications

  • Shelters
  • Tactical Systems
  • Shipboard Power
  • HMMWVs
  • Mobile Systems
  • Ground Support
  • Aircraft

Compliance (by test or similarity)

  • MIL-STD-810
  • MIL-STD-1275(1)
  • MIL-STD-461(2)
  • MIL-STD-167
  • MIL-STD-704
  • MIL-S-901(3)

(1) May require additional external module.
(2) May require external EMI Filter.
(3) Requires external shock absorbers.

 

Partial Standard Product Listing
105-150 VDC Operating Input / 100 W – 3.5 KW
(Consult factory for higher power ratings)
60 Hz Models
Models Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
NGL1060-120 120 60 120 VA / 100 W 2.4 2.68×4.50×7.75 pdf_icon
NGL1K60-120 120 60 1.2 KVA / 1 KW 5 2.60×5.00×10.00 pdf_icon
NGL2K60-120 120 60 2.5 KVA / 2 KW 14 5.00×8.00×12.50 pdf_icon
NGL3K60-120 120 60 3.5 KVA / 3 KW 15 5.00×8.00×12.50 pdf_icon
NGL3.5K60-120 120 60 4.5 KVA / 3.5 KW 16.3 5.00×8.00×14.77 pdf_icon
50 Hz Models
Models Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
NGL1050-120 220 50 120 VA / 100 W 2.4 2.68×4.50×7.75 pdf_icon
NGL1K50-120 220 50 1.2 KVA / 1 KW 5 2.60×5.00×10.00 pdf_icon
NGL2K50-120 220 50 2.5 KVA / 2 KW 14 5.00×8.00×12.50 pdf_icon
NGL3K50-120 220 50 3.5 KVA / 3 KW 15 5.00×8.00×12.50 pdf_icon
NGL3.5K50-120 220 50 4.5 KVA / 3.5 KW 16.3 5.00×8.00×14.77 pdf_icon
400 Hz Models
Models Output VAC Output Freq. (Hz) Cont. Output Power Weight (Lb) Size in.(HxWxL) Outline Drawing
NGL10400-120 115 400 120 VA / 100 W 2.4 2.68×4.50×7.75 pdf_icon
NGL1K400-120 115 400 1.2 KVA / 1 KW 5 2.60×5.00×10.00 pdf_icon
NGL2K400-120 115 400 2.5 KVA / 2 KW 14 5.00×8.00×12.50 pdf_icon
NGL3K400-120 115 400 3.5 KVA / 3 KW 15 5.00×8.00×12.50 pdf_icon
NGL3.5K400-120 115 400 4.5 KVA / 3.5 KW 16.3 5.00×8.00×14.77 pdf_icon
Partial Three Phase Model Selection - Lower and Higher Capacities Available - Consult Factory
3 Phase Models Output VAC Output Freq. (Hz) Cont. Output Power Approx. Weight (Lb) Size in.(HxWxL) Rack Panel Height in. OPT/STD Outline Drawing Picture
NGL3K3/6-120 (120/208) 120/208 60 3KVA 35 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL3K3/5-120 (220/380) 220/380 50 3KVA 35 5.25x19x22 5.25 STD pdf_icon GL3K3/5-24 (220/380)
NGL3K3/4-120 (115/200) 115/200 400 3KVA 35 5.25x19x22 5.25 STD pdf_icon GL3K3/4-24 (115/200)
NGL4.5K3/6-120 (120/208) 120/208 60 4.5KVA 60 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL4.5K3/5-120 (220/380) 220/380 50 4.5KVA 60 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL4.5K3/4-120 (115/200) 115/200 400 4.5KVA 60 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL6K3/6-120 (120/208) 120/208 60 6KVA 65 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL6K3/5-120 (220/380) 220/380 50 6KVA 65 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL6K3/4-120 (115/200) 115/200 400 6KVA 65 5.25x19x22 5.25 STD pdf_icon GL3K3/6-24 (120/208)
NGL9K3/6-120 (120/208) 120/208 60 9KVA C/F C/F C/F OPT/STD
NGL9K3/5-120 (220/380) 220/380 50 9KVA C/F C/F C/F OPT/STD
NGL9K3/4-120 (115/200) 115/200 400 9KVA C/F C/F C/F OPT/STD
ELECTRICAL
  • Input Voltage: 105-150 VDC
  • Output Voltage: See MODELS tab
  • Frequency: 50 Hz, 60 Hz, 400 Hz (±0.5%)
  • Frequency Regulation: ±0.5% N.L. to F.L.
  • Voltage Regulation: ±1.5% N.L. to F.L.
  • Efficiency: Approximately 80% (depending on model)
  • Reactive Load: 0.75 Lead to 0.75 Lag
  • Distortion: 5% THD, 3% Single Harmonic
  • Overload: 125% for 5 minutes
  • Overload Protection Range: Automatic overload & short circuit protection
  • Isolation: 1500 Volt
  • Transient Response: Approx. 3 cycle recovery to 95% of nominal
ENVIRONMENTAL & MECHANICAL
  • Operating Temp: -20°C to +50°C Std -30°C to +60°C Optional
  • Storage Temp: -40°C to +71°C
  • Cooling: By internal DC brushless fan
  • Vibration: Normal shipping and handling
  • Shock: 20g, 11 mS half sinewave
  • Humidity: To 95% RH non-condensing
  • EMI: Designed to meet FCC Part 15, Class A; can meet MIL-STD-461 with optional filtering

OPTIONS

  • Ruggedization against high shock, vibration and humidity
  • MS connector mates
  • Multiple output outlets
  • Chassis Slide Guides
  • Electromechanical transfer switch
  • Custom enclosures
  • 3Ø Power Input
  • Premium Wide-Temp Range VRLA batteries with up to 12 year life
  • “LIFE” models feature internal Lithium Iron Phosphate batteries with embedded Battery Management System for substantial weight savings and longer run time.
  • Additional run time via external batteries
  • 400 Hz input and / or output
  • CAD Free Connectors
  • Non-PVC wiring
  • 28 VDC Input
  • High IP Protection for front / rear panels (typically IP32,) including louvers on all intake and exhaust, as well as fully gasketed breakers, switches, and indicators.
  • AUX DC Outputs
  • RTCA/DO-160G Compliant Aircraft Grade Package
  • Power Distribution Units (PDUs)
  • Environmental Stress Screening Services

NGL Series Pure Sine Wave DC-AC Inverters PDF Data Sheet

You've just added this product to the cart: