Jupiter Series 10-320+ KVA 350 VDC Pure Sine Wave DC-AC Inverters

  • Complete input to output Galvanic Isolation.
  • High frequency (almost silent) operation
  • Push button starting and stopping
  • Diagnostic panel with LCD and LED display
  • Soft start on inverter
  • Overload & and short circuit protection
  • Optional Solid state transfer switch built in
  • Optional Maintenance bypass switch built in
  • All electronics are built in modular front-access cabinets and have front removable subassemblies for easy service and maintenance
  • FCC class A approved
  • Remote isolated dry relay contacts
  • Available options to meet military specs, including MIL-STD-461, MIL-STD-167, MIL-STD-810
Compare

Description

Nova’s Jupiter-Series Pure Sine Wave DC-AC Inverters are high-reliability power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally. These models utilize state of the art technology and the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications.

Typical applications include:

  • Military: UAV, Shipboard, Submarine, Aircraft, Mobile Power Units, Shelters
  • Heavy Industrial Applications
  • Demanding Commercial Applications
  • Communications Systems
300-420 VDC Operating Input / 10 KVA – 320 KVA
(Consult factory for higher power ratings)
Standard Model Selection
60 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
MODELOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K60-350 120 6010KVA / 8KW 75063x22x31.5 QUOTE
J20K60-350 120 6020KVA / 16KW 800 63x22x31.5 QUOTE
J30K60-350 120 6030KVA / 24KW 840 63x22x31.5 QUOTE
J40K60-350 120 6040KVA / 32KW 95063x22x31.5 QUOTE
J50K60-350 120 6050KVA / 40KW 176063×43.5×31.5 QUOTE
J60K60-350 120 6060KVA / 48KW 187063×43.5×31.5 QUOTE
J80K60-350 120 6080KVA / 64KW 242063x87x31.5 QUOTE
J100K60-350 120 60100KVA / 80KW 308063x87x31.5 QUOTE
J120K60-350 120 60120KVA / 96KW 308063x87x31.5 QUOTE
J160K60-350 120 60160KVA / 128KW 308063x87x31.5 QUOTE
J200K60-350 120 60200KVA / 160KW 3520 63x87x31.5 QUOTE
50 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
MODELOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K50-350 (220)220 50 10KVA / 8KW 63863x22x31.5 QUOTE
J20K50-350 (220) 220 50 20KVA / 16KW 770 63x22x31.5 QUOTE
J30K50-350 (220) 220 50 30KVA / 24KW 990 63x22x31.5 QUOTE
J40K50-350 (220) 220 50 40KVA / 32KW 121063x22x31.5 QUOTE
J50K50-350 (220) 220 50 50KVA / 40KW 1650 63×43.5×31.5 QUOTE
J60K50-350 (220) 220 50 60KVA / 48KW 187063×43.5×31.5 QUOTE
J80K50-350 (220) 220 50 80KVA / 64KW 209063×43.5×31.5 QUOTE
J100K50-350 (220) 220 50 100KVA / 80KW 2420 63×43.5×31.5 QUOTE
J120K50-350 (220) 220 50 120KVA / 96KW 330063x87x31.5 QUOTE
J160K50-350 (220) 22050160KVA / 128KW 396063x87x31.5 QUOTE
J200K50-350 (220) 22050200KVA / 160KW 484063x87x31.5 QUOTE
400 Hz Single Phase Models
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch
MODELOUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K400-350 11540010KVA / 8KW 638 63x22x31.5 QUOTE
J20K400-350 11540020KVA / 16KW 77063x22x31.5 QUOTE
J30K400-350 11540030KVA / 24KW 990 63x22x31.5 QUOTE
J40K400-350 11540040KVA / 32KW 1210 63x22x31.5 QUOTE
J50K400-350 11540050KVA / 40KW 165063×43.5×31.5 QUOTE
J60K400-350 11540060KVA / 48KW 187063×43.5×31.5 QUOTE
J80K400-350 11540080KVA / 64KW 209063×43.5×31.5 QUOTE
J100K400-350 115400100KVA / 80KW 242063×43.5×31.5 QUOTE
J120K400-350 115400120KVA / 96KW 330063x87x31.5 QUOTE
J160K400-350 115400160KVA / 128KW 3960 63x87x31.5 QUOTE
J200K400-350 115400200KVA / 160KW 484063x87x31.5 QUOTE
3 Phase Models
3 PHASE MODEL OUTPUT VAC OUTPUT FREQ. (HZ) CONT. OUTPUT POWER WEIGHT (LB) SIZE IN.(HXWXL) OUTLINE DRAWING
J10K3/5-350 (220/380) 220/380 5010KVA66063x22x31.5 QUOTE
J10K3/6-350 (120/208) 120/208 6010KVA64063x22x31.5 QUOTE
J10K3/4-350 (115/200) 115/200 40010KVA64063x22x31.5 QUOTE
J20K3/5-350 (220/380) 220/380 5020KVA79063x22x31.5 QUOTE
J20K3/6-350 (120/208) 120/208 6020KVA77063x22x31.5 QUOTE
J20K3/4-350 (115/200) 115/200 40020KVA77063x22x31.5 QUOTE
J30K3/5-350 (220/380) 220/380 5030KVA101063x22x31.5 QUOTE
J30K3/6-350 (120/208) 120/208 6030KVA99063x22x31.5 QUOTE
J30K3/4-350 (115/200) 115/200 40030KVA99063x22x31.5 QUOTE
J40K3/5-350 (220/380) 220/380 5040KVA123063x22x31.5 QUOTE
J40K3/6-350 (120/208) 120/208 6040KVA121063x22x31.5 QUOTE
J40K3/4-350 (115/200) 115/200 40040KVA121063x22x31.5 QUOTE
J50K3/5-350 (220/380) 220/380 5050KVA158063x22x31.5 QUOTE
J50K3/6-350 (120/208) 120/208 6050KVA154063x22x31.5 QUOTE
J50K3/4-350 (115/200) 115/200 40050KVA154063x22x31.5 QUOTE
J60K3/5-350 (220/380) 220/380 5060KVA180063x22x31.5 QUOTE
J60K3/6-350 (120/208) 120/208 6060KVA176063x22x31.5 QUOTE
J60K3/4-350 (115/200) 115/200 40060KVA176063x22x31.5 QUOTE
J80K3/5-350 (220/380) 220/380 5080KVA204063×43.5×31.5 QUOTE
J80K3/6-350 (120/208) 120/208 6080KVA198063×43.5×31.5 QUOTE
J80K3/4-350 (115/200) 115/200 40080KVA198063×43.5×31.5 QUOTE
J100K3/5-350 (220/380) 220/380 50100KVA249063×43.5×31.5 QUOTE
J100K3/6-350 (120/208) 120/208 60100KVA242063×43.5×31.5 QUOTE
J100K3/4-350 (115/200) 115/200 500100KVA242063×43.5×31.5 QUOTE
J120K3/5-350 (220/380) 220/380 50120KVA341063×43.5×31.5 QUOTE
J120K3/6-350 (120/208) 120/208 60120KVA333063×43.5×31.5 QUOTE
J120K3/4-350 (115/200) 115/200 400120KVA333063×43.5×31.5 QUOTE
J160K3/5-350 (220/380) 220/380 50160KVA410063×43.5×31.5 QUOTE
J160K3/6-350 (120/208) 120/208 60160KVA396063×43.5×31.5 QUOTE
J160K3/4-350 (115/200) 115/200 400160KVA396063×43.5×31.5 QUOTE
J200K3/5-350 (220/380) 220/380 50200KVA490063x87x31.5 QUOTE
J200K3/6-350 (120/208) 120/208 60200KVA4840 63x87x31.5 QUOTE
J200K3/4-350 (115/200) 115/200 400200KVA4840 63x87x31.5 QUOTE
J300K3/5-350 (220/380)220/38050240KVA576063x87x31.5 QUOTE
J240K3/6-350 (120/208) 120/208 60240KVA576063x87x31.5 QUOTE
J300K3/4-350 (115/200) 115/200 400240KVA576063x87x31.5 QUOTE
J300K3/5-350 (220/380) 220/380 50300KVA6160 63x87x31.5 QUOTE
J300K3/6-350 (120/208) 120/208 60300KVA616063x87x31.5 QUOTE
J300K3/4-350 (115/200) 115/200 400300KVA616063x87x31.5 QUOTE
J320K3/5-350 (220/380) 220/380 50320KVA651063x87x31.5 QUOTE
J320K3/6-350 (120/208) 120/208 60320KVA651063x87x31.5 QUOTE
J320K3/4-350 (115/200) 115/200 400320KVA651063x87x31.5 QUOTE
Specifications for the Nova Electric Jupiter Series DC-AC Inverters
300-420 VDC Input (Extended Range Available) / Single or Three Phase Pure Sine Wave VAC Output
KVA 10 20 30 40 50 60 80 100 120 160 200
INVERTER
Output Voltage (VAC) Please Specify:
Three Phase WYE 115/200 | 120/208 | 220/380 | 230/400 | 240/415 | 277/480
Three Phase DELTA 120 3 ph delta |220 3 ph delta | 240 3 ph delta | 380 3 ph delta | 480 3 ph delta
Single Phase 120 1 ph | 220 1 ph | 240 1 ph | 480 1 ph
Other Voltages Available Optionally
Wave Form Sinewave
Output Power Factor 0.7 lead to 0.7 lag
Frequency Lock Range 50 / 60 Hz + 0.1 Hz (crystal controlled)
Output Frequency (free running) 50 / 60 / 400 Hz (please specify)
Phase Shift Under 100% Unbalanced Load <0.5%
THD (Linear Load) 2% typical 3% max
  OVERLOAD
<110% Continuous
>110-125% Up to 15 minutes
>125-150% Up to 5 minutes
>150-170% Up to 30 seconds
>170-200% Up to 15 seconds
Efficiency (100% Load) 90% 90.5% 90% 91%
STATIC SWITCH (optional)
Voltage Range Same as AC output. (Different voltages are available upon request)
Mains <-> Inverter 0 ms (True Online)
BTU/h @ Full Load (Approx, Max) 2.4K 4.8K 6.5K 8.9K 10.3K 12K 16K 19K 22K 30K 45K
Audible Noise <65 dBA (at 1m) <67 dBA (at 1m)
Temperature 0-50ºC (32-122ºF) (Other ranges available)
Humidity 0%-95% (Non-condensing)
Altitude Up to 1500 m Above Sea Level
EN50091-1, -2 Yes
Short Circuit Protection Yes
Lightning / EMC Filter MOV / Input & Output ( FCC CLASS A)
Galvanic Isolation Input and Output True Galvanic Isolation
LED, LCD, Audible Alarm Yes
Remote Control and Communication Interface Choices Dry Contact, RS-232, RS-485 (Optional,) UPScan Monitoring 1~99 Units Simultaneously (Optional,) Netagent (Optional,) MODBUS (Optional)

OPTIONS

  • Ruggedization: Ruggedization is highly recommended for harsh environment applications, and includes conformal coating of the Inverter’s PCBs to protect against humidity, condensation, and fungus growth. This option does not affect size or weight. For military applications, we offer more structural ruggedization, as well as shock mounts, to comply with such standards as MIL-S-901, MIL-STD-810, and other demanding MIL-Specs.
  • UPScan Remote Monitor Panel: This is a hand held remote display and control module with LCD and LED display that can monitor up to 99 Inverters at a remote distance of up to 3,000 feet via RS-485.
  • NETAGENT:  This provides capability to monitor the Inverter over the internet.  It includes the appropriate additional SNMP card and microprocessor.  When equipped with this option, the user can connect a CAT-5 cable for interface to the external LAN.
  • Complete Spare Parts Package: We offer a comprehensive spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans.  These spare parts kits are priced lower when ordered with the initial order then if they are ordered later on.
  • Factory Turn-On Service: We offer a turn on service for a fee that will ensure the unit has been properly installed and the full warranty is in effect.  (Failures caused by incorrect installation are not covered by the warranty.)  If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.  This service is provided by factory engineers, not third party engineers. Pricing is dependent upon location, number of units, airfare rates, etc. Please contact us for more details if interested.
  • Internal Solid-State Static Transfer Switch
  • AUX DC Outputs
  • Casters for Portability (22″ Wide Models Only)
  • Power Distribution Units (PDUs)
  • Environmental Stress Screening Services

Jupiter-Series Models can be equipped with options to meet*:

MIL-STD-810 – for shock, vibration, humidity, and temperature
MIL-STD-167 – for vibration
MIL-STD-461 – for EMI
MIL-S-901 – for shock

*Compliance to these “designed to meet” standards based on similarity to previously qualified designs. Formal Qual Testing to these and other standards is available optionally.

Jupiter Series High Power Pure Sine Wave DC-AC Inverters PDF Data Sheet