Navy Galaxy Series 5 KVA Rugged True Online UPS
- Formally Qualified to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-810, MIL-STD-740, and IEC 68-2-6
- Field Proven Reliability
- Lithium Iron Phosphate Batteries Available Optionally
- Double-Conversion UPS Systems
- Rack-Mount, Double-Conversion UPS Systems
- Rugged UPS System
- Military UPS System
- True Online UPS Technology
- Description
- Models
- Specifications
- Popular Options
- System Compliance
- Data Sheets
Description
Nova Electric’s rugged Navy Galaxy-Series true online UPS Systems are specifically designed for submarine and shipboard applications in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-810, MIL-STD-740, and IEC-68-2-6. These units are in heavy use on the US Virginia Class Submarine, as well as countless other high profile shipboard and submarine applications in US and US-friendly fleets worldwide. This true online UPS series has a three-phase power factor corrected (PFC) input of 115 VAC L-L, 50/60 Hz per MIL-STD-1399 Section 300 Type I and a pure sinewave galvanically isolated output. Output frequency is available in 50, 60, or 400 Hz (specify.)
Model Selection
MODEL | KVA / KW | INPUT | OUTPUT | UPS (LBS) | RUN TIME | BATTERY (LBS) | OUTLINE DRAWING | |
---|---|---|---|---|---|---|---|---|
NGRS11-5K60-115(D)-115 | 5 / 2.5 | 115VAC L-L | 115VAC | 125 | 10 min | 120 | QUOTE |
ELECTRICAL
- Input Voltage: 115 VAC L-L, 50/60 Hz per MIL-STD-1399 Section 300 Type I
(other voltages available optionally) - Input Frequencies available (specify): 50, 60 or 400 Hz
- Output Voltages available (specify): 115, 120, 208, 220, 230, or 240 VAC 1Ø
- Output Frequency (specify): 50, 60 or 400Hz
- Voltage Regulation: +/- 2% NL to FL
- Frequency Regulation: 0.1%
- Harmonic Distortion: 2% THD Typical 5% Max
- Input Power Factor: 0.99
- Efficency at full load: 82% typical
- Overload: 125% for 5 minutes
EXTERNAL BATTERIES
- 3.5″ High x 19″ Wide x 24.125″ Deep / 120 Pounds
External 96 VDC nominal rack mount battery drawer containing sealed maintenance-free, user-replaceable premium wide-temp batteries rated for 8-10 years lifetime. Battery cabinets and racks available for UPS runtime from 5 minutes to 24+ hours.
PROTECTIVE FEATURES
- AC & DC Input Circuit Breakers
- Low Battery Shut Off
- Overload and Thermal Protection
- Audible Alarm with Silence Switch
- Optional EPO
ENVIRONMENTAL
- Operating Temperature: -20° to +50° C per MIL-STD-810D
- Storage Temperature Range: -30° to +60° C
- Humidity: to 95% non-condensing
- Elevation: 15,000 Ft. (4.572m) operating
40,000 Ft (12.192m) non-operating - Audible noise: Less than 55 dBA at 5 ft. (1.5 m)
- EMI: Per MIL-STD-461B/E
- Vibration: Per IEC 68-2-6 Type I
- Shock: 20g for 20ms half sinewave per MIL-STD-901C Grade A
- Structureborne Noise: MIL-STD-740B Grade A
- MTBF: 30,000 hours
- MTTR: 30 Minutes
ALARM AND DIAGNOSTICS
- System Status: Green/Red
- Utility Off: Red
- UPS Off: Red
- Low Battery: Red
- Logic Fault: Red
- UPS Overload: Red
- Over-Temperature: Red
- Load on Utility: Red (with XFR SW option)
COMMUNICATIONS
- Alarm Contacts: Standard
- RS 232 or SNMP: Optional
- Power Distribution Units
- MS Connector Mates and Multiple Output Outlets
- Chassis Slide Guides
- Internal Transfer Switch
- Rugged Transit Cases and Custom Enclosures
- Additional Run Time via External Batteries
- 400 Hz Input and / or Output
- CAD Free Connectors
- Non-PVC wiring
- 28 VDC Input
- High IP Protection for front / rear panels
- AUX DC Outputs
- Environmental Stress Screening Services
SYSTEM COMPLIANCE
MIL-STD-1399 Section 300B: For Type I apparatus
Additional Ruggedization to meet MIL-STD-901, IEC 68-2-6, and MIL-STD-810: The UPS System’s construction is extremely robust, and ruggedized throughout. All components and modules within the unit are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth.
MIL-STD-901C for Grade A, Class II Equipment: Shock test with half sinewave, 20ms duration, 15g peak acceleration shock pulse.
IEC 68-2-6 for Type I Testing: Between 3-10 Hz amplitude to be 0.5mm. Between 10-50Hz acceleration to be 2 m/s2
MIL-STD-810D: Operating Temperature Tests including High Temperature Test per Procedure II, Method 501.2, Table 501.2-II Ambient Air, 4 Cycles @ 24 Hours per cycle, Low Temperature Test per Procedure II, Method 505.2, Table 505.2-I Region CO, 4 Cycles @ 24 Hours per cycle, and Temperature Shock Test per Procedure I, Method 503.2, between 0-40 degrees Celsius, 4 Cycles @ 24 Hours per cycle.
MIL-STD-740B Structureborne and Airborne Noise: For Grade A Type III Equipment.
Internal EMI Reduction Package to meet MIL-STD-461: The design of this unit is specifically focused on reducing EMI emissions. The UPS contains substantial internal filtering to minimize EMI emissions. Inputs which may be susceptible to transients are protected by several methods, including MOVs. All internal magnetics are shielded with copper and mu-metal to further minimize emissions. The compact rack mount chassis is specifically treated with low surface resistivity finishes on the interior. All aluminum parts are treated with clear irridite. The steel parts are treated with zinc plate, followed by a clear chromate. All exterior portions (except for mating surfaces) are then painted with glossy ANSI-61 gray to assure excellent bonding of mating sheet metal parts. All input and output ventilation filters include metal honeycomb-style filters.
MIL-STD-461B Part VI for EMI Class A5: CE01, CE03, CS01, CS02, CS06, CS09, RE01, RE02, RS01, RS02, RS03.
Super-Rugged, Long Life Hawker Energy Batteries: External Hawker Energy sealed, maintenance free batteries provide 10 minutes back up time at full load. These batteries are extremely resistant to shock, vibration, and wide temperature ranges. Also, they have a very long service life (8-10 years measured at 25 degrees Celsius ambient temperature) for a minimum of maintenance. The batteries are user replaceable.
Pressure Tests for Submarine Usage: The Navy Galaxy Series UPS System was tested to atmospheric pressure within the range of 750-1250 millibars, and maintained standard operation to specification to the following test pressures for 1 hour:
250 millibars above ambient (applied within 30 seconds and released within 30 seconds)
250 millibars below ambient (applied within 30 seconds and released within 30 seconds)
Ambient pressure of 1000 millibars