Ultra Lightweight Galaxy Series 0.9 – 5 KVA Solid-State Rack Mount Frequency Converters

  • Formally Qualified to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, DOD-STD-1399, (and RTCA/DO-160 – optionally.)
  • Compact Chassis (1U – 4U Tall)
  • Ultra Lightweight Design
  • Power Factor Corrected Universal Input
  • SNMP Communications
  • Battery Backup Available Optionally
  • Heavy-Duty Industrial Applications
  • Demanding Commercial Applications
  • Communications Systems
  • Power Conditioning
  • Export Testing
Compare

Description

Nova’s Ultra Lightweight Galaxy-Series Solid-State Frequency Converter Systems are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD-1399. RTCA/DO160 is available optionally. These models offer maximum field-proven reliability for severe environment and high reliability applications such as:

  • Military Applications: Including HMMWV, UAV, Shipboard, Submarine, Aircraft, Mobile Power Units, Shelters, Transportable Systems, Tactical Systems, Ground Support, Drone Systems, and more
  • Heavy-Duty Industrial Applications
  • Demanding Commercial Applications
  • Communications Systems

These Converters have a highly flexible design architecture which allows adaptation to practically all military applications. The Power Factor Correction circuit allows compliance to the CE mark’s “Low Voltage Directive,” so the units can operate on a wide input range from 100-250 Volts AC, on any standard frequency including 50, 60, or 400 Hz. Three phase input is also available if desired. Isolated output permits grounding the input neutral and / or optionally grounding output neutral as well.

Many communication platforms are supported, including RS232, SNMP, RS485, and CANbus. A multitude of connectors are available, as are different types of chassis slides.

Nova Electric’s Ultra Lightweight Converters are deployed in countless high profile military programs aboard Naval ships and submarines, on satellite trailers and mobile shelters, and military ground vehicles and aircraft, with a field-proven MTBF exceeding 100,000 hours. These units are the first choice for the world’s leading defense contractors including Lockheed Martin, Boeing, Raytheon, General Dynamics, DRS, BAE, all branches of the US Armed Forces, and US allied forces worldwide. Please contact us today for more information.

60 Hz Output Models
MODELKVAKWNOMINAL INPUT INPUT FREQ. OUTPUT VAC OUTPUT FREQ. F.C (LBS) HEIGHTOUTLINE DRAWING VIDEO
GLFCPFC5K60-120/240A-120-4U 54120-240VAC 50/60Hz 12060Hz454U QUOTE
GLFCPFC3K60-120/240A-120-4U 33120-240VAC 50/60Hz 12060Hz424U QUOTE
GLFCPFC3K60-120/240A-120-3U 32.4120-240VAC 50/60Hz 12060Hz403U QUOTE
GLFCPFC2K60-120/240A-120-3U 21.6120-240VAC 50/60Hz 12060Hz403U QUOTE
GLFCPFC1.5K60-120/240A-120-2U 1.51.2120-240VAC 50/60Hz 12060Hz302U QUOTE
GLFCPFC1K60-120/240A-120-1U 0.90.7120-240VAC 50/60Hz 12060Hz251U QUOTE
50 Hz Output Models
MODELKVAKWNOMINAL INPUT INPUT FREQ. OUTPUT VAC OUTPUT FREQ. F.C (LBS) HEIGHTOUTLINE DRAWING VIDEO
GLFCPFC5K50-120/240A-230-4U 54120-240VAC 50/60Hz 23050Hz454U QUOTE
GLFCPFC3K50-120/240A-230-4U 33120-240VAC 50/60Hz 23050Hz424U QUOTE
GLFCPFC3K50-120/240A-230-3U 32.4120-240VAC 50/60Hz 23050Hz403U QUOTE
GLFCPFC2K50-120/240A-230-3U 21.6120-240VAC 50/60Hz 23050Hz403U QUOTE
GLFCPFC1.5K50-120/240A-230-2U 1.51.2120-240VAC 50/60Hz 23050Hz302U QUOTE
GLFCPFC1K50-120/240A-230-1U 0.90.7120-240VAC 50/60Hz 23050Hz251U QUOTE
400 Hz Output Models
MODELKVAKWNOMINAL INPUT INPUT FREQ. OUTPUT VAC OUTPUT FREQ. F.C (LBS) HEIGHTOUTLINE DRAWING VIDEO
GLFCPFC5K400-120/240A-115-4U 54200-240VAC 50/60Hz 115400Hz454U QUOTE
GLFCPFC3K400-120/240A-115-4U 33120-240VAC 50/60Hz 115400Hz424U QUOTE
GLFCPFC3K400-120/240A-115-3U 32.4120-240VAC 50/60Hz 115400Hz403U QUOTE
GLFCPFC2K400-120/240A-115-3U 21.6120-240VAC 50/60Hz 115400Hz403U QUOTE
GLFCPFC1.5K400-120/240A-115-2U 1.51.2120-240VAC 50/60Hz 115400Hz302U QUOTE
GLFCPFC1K400-120/240A-115-1U 0.90.7120-240VAC 50/60Hz 115400Hz251U QUOTE
ELECTRICAL
  • Input Voltage: 120/240 VAC Autoselect PFC (3Ø input optional)
  • Output Voltage: 120, 208, or 230 VAC (specify)
  • Frequency: 50 / 60 / 400 Hz. Available
  • Voltage Regulation: ± 2% NL to FL
  • Frequency Regulation: ± 0.5% NL to FL
  • Harmonic Distortion: 5% THD, 3% typical
  • Input Power Factor: 0.95 or Better @ half-full load
  • Efficiency at full load: 80-85% @ full load typical
  • Connections: MS Connector (mates opt.)
  • Overload:
    110% load for 10 minutes
    115% load for 5 minutes
    120% load for 2 minutes
NOMINAL DIMENSIONS
  • Dimensions:
    19″ Wide x 24″ Deep (See chart for height)
PROTECTIVE FEATURES
  • Input Circuit Breakers
  • Overload Protection Range: Automatic overload & short circuit protection
  • Thermal Protected
  • Input Under/Overvoltage Protected
  • Optional Audible Alarm with Silence Switch
ENVIRONMENTAL
  • Operating Temp.: -20° to +50°C (Extended ranges optional)
  • Storage temperature range: -40° to +71°C
  • Humidity: to 95% RH non-condensing per MIL-STD-810. All boards conformal coated with Acrylic MIL-I-46058 Type R.
  • Elevation: 15,000 Ft. (4,572m) operating;
    40,000 ft. (12,192m) non-operating
  • Shock: 20g, 11 mS half sinewave per MIL-STD-810
  • Audible Noise: Less than 55 dbA at 5 ft.
  • EMI: MIL-STD-461
  • MTBF: 100,000+ hours per field data @ +25C Ambient Ground-Fixed
  • MTTR: 30 minutes by qualified personnel
STANDARD REMOTE CONTACTS
  • SNMP V1.0 (Available-Optional) via CAT-5 Connector
  • Major Alarm: Logic Fault,, Overtemperature, Frequency Converter Overload
  • Minor Alarm: Utility Off
  • RS 232 (Available-Optional) Via DB 9 Connector
  • Alarm Contacts (Available-Optional)
INDICATORS
  • AC Input On
  • AC Output On
OPTIONAL AUDIBLE ALARM
  • Audible alarm with silence switch

OPTIONS

MIL-STD-1399 Section 300B: For Type I apparatus

MIL-STD-740-1: Airborne Sound Measurements for Shipboard Equipment

MIL-STD-740-2: Structureborne Vibratory Acceleration Measurements

Additional Ruggedization to meet MIL-STD-901, MIL-STD-167, MIL-STD-810, and DOD-STD-1399: The System’s construction is extremely robust, and ruggedized throughout. All components and modules within the unit are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth.

MIL-S-901D for Grade A, Class III, Type B Equipment
(mounted in shock-isolated rack attenuating to 20g/11ms max)

MIL-STD-167-1 for Type I Equipment

MIL-STD-810:

    • Air Temperature per MIL-STD-810F Method 502.4, Procedure II
    • Steady State Temperature per MIL-STD-810F, Method 501.4, Procedure I (Constant Temperature) and Method 502.4, Procedure I
    • Temperature Shock per MIL-STD-810F, Method 503.4, Procedure II, Cyclic.
    • Thermal Shock testing per MIL-STD-810G, Method 503.5, Procedure I-D
    • High Temperature Storage per MIL-STD-810G, Method 501.5, Procedure I
    • Low Temperature Storage testing per MIL-STD-810G, Method 502.5, Procedure I
    • High Temperature Operating per MIL-STD-810G, Method 501.5, Procedure II
    • Low Temperature Operating per MIL-STD-810G, Method 502.5, Procedure II
    • Operational Humidity per MIL-STD-810F Method 507.4.
    • Humidity per MIL-STD-801G, Method 507.5, Procedure I
    • Storage and Transportation Humidity per MIL-STD-810F, Method 507.4
    • Salt Fog Atmosphere per MIL-STD-810F Method 509.4
    • Altitude per MIL-STD-810F, Method 500.4, Procedure I, Storage/Air Transport.
    • Operating and Non-Operating Altitude Testing per MIL-STD-810G, Method 500.5, Procedure II
    • Rapid Decompression per MIL-STD-810F, Method 500.4, Procedure III
    • Transit Shock per MIL-STD-810F, Method 516, Procedures IV, V and VI
    • Transportation Vibration per MIL-STD-810F, Method 514.5, Procedure II for loose cargo transportation
    • Transportation Vibration per MIL-STD-810G, Method 514-6, Procedure I, Category 20
    • Transit Drop per MIL-STD-810F, Method 516.5, Procedure IV
    • Transit Drop per MIL-STD-810G, Method 516.6, Procedure IV
    • Bench Handling per MIL-STD-810F, Method 516.5, Procedure VI
    • Bench Handling per MIL-STD-810G, Method 516.6, Procedure VI

DOD-STD-1399 Section 301A Table V –Design Limits for Ship Motion

Internal EMI Reduction Package to meet MIL-STD-461: The design of this unit is specifically focused on reducing EMI emissions. The unit contains substantial internal filtering to minimize EMI emissions. Inputs which may be susceptible to transients are protected by several methods. The compact rack mount chassis is specifically treated with low surface resistivity finishes on the interior. All aluminum parts are treated with clear irridite. The steel parts are treated with zinc plate, followed by a clear chromate. Paint method via ANSI-61 gray is designed to assure excellent bonding of mating sheet metal parts. All input and output ventilation filters include metal honeycomb-style or mesh filters.

MIL-STD-461E: CE101, CE102, CS101, CS114, CS116, RE102, RS101, and RS103

Ultra Lightweight Galaxy Series 0.9 – 5 KVA Solid-State Frequency Converters PDF Data Sheet