Jupiter Series 10-900 KVA High Power Solid-State Frequency Converters

  • Complete input to output Galvanic Isolation
  • High frequency (almost silent) operation
  • Push button starting and stopping
  • Diagnostic panel with LCD and LED display
  • Soft start
  • Overload & and short circuit protecion
  • Maintenance free batteries can be added for UPS capability (consult factory)
  • All electronics are built in modular front-access cabinets and have front removable subassemblies for easy service and maintenance
Compare Compare

Description

Nova’s Jupiter-Series Solid-State Frequency Converters are high-reliability power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally. These models utilize state of the art technology and the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications. Single-phase input and/or output models are available upon request. Typical applications include:

  • Military: HMMWV, UAV, Shipboard, Submarine, Aircraft and Mobile Power Units, Shelters
  • Aircraft Power
  • Communications Systems
  • Cellular Sites
  • European Power / Export Testing
  • Power Conditioning & Frequency Stabilization
  • U.S. Power Abroad
  • Railroad Signaling Power – 25, 91.667, 100, 200, 209, and 250 Hz. available
50 Hz Three-Phase Output Models

MODELKVAKWIN (VAC) OUT (VAC) SIZE IN.(HXWXL) WEIGHT (KG) WEIGHT (LBS) OUTLINE DRAWING
JFC10K3/5-120/208-220/380 108120/208 220/380 63x22x31.5 290638 QUOTE
JFC20K3/5-120/208-220/380 2016120/208 220/380 63x22x31.5 330726 QUOTE
JFC30K3/5-120/208-220/380 3024120/208 220/380 63x22x31.5 4801056 QUOTE
JFC40K3/5-120/208-220/380 4032120/208 220/380 63x22x31.5 5601232 QUOTE
JFC50K3/5-120/208-220/380 5040120/208 220/380 63x22x31.5 6501430 QUOTE
JFC60K3/5-120/208-220/380 6048120/208 220/380 63x22x31.5 7801716 QUOTE
JFC80K3/5-120/208-220/380 8064120/208 220/380 63×43.5×31.5 9202024 QUOTE
JFC100K3/5-120/208-220/380 10080120/208 220/380 63×43.5×31.5 10502310 QUOTE
JFC120K3/5-120/208-220/380 12096120/208 220/380 63×43.5×31.5 13002826 QUOTE
JFC160K3/5-120/208-220/380 160128120/208 220/380 63×43.5×31.5 16003520 QUOTE
JFC200K3/5-277/480-220/380 200160277/480220/380 63×87.0x31.5 27005940 QUOTE
JFC240K3/5-277/480-220/380 240192277/480220/380 63×87.0x31.5 29006380 QUOTE
JFC300K3/5-277/480-220/380 300240277/480220/380 63×87.0x31.5 32007040 QUOTE
JFC320K3/5-277/480-220/380 320256277/480220/380 63×87.0x31.5 33007260 QUOTE
JFC450K3/5-277/480-220/380 450360277/480220/380 63x130x31.5 510011385 QUOTE
JFC600K3/5-277/480-220/380600480277/480220/38075x154x39.5588612950 QUOTE

60 Hz Three-Phase Output Models

MODELKVAKWIN (VAC) OUT (VAC) SIZE IN.(HXWXL) WEIGHT (KG) WEIGHT (LBS) OUTLINE DRAWING
JFC10K3/6-220/380-120/208 108220/380 120/208 63x22x31.5 270590 QUOTE
JFC20K3/6-220/380-120/208 2016220/380 120/208 63x22x31.5 300660 QUOTE
JFC30K3/6-220/380-120/208 3024220/380 120/208 63x22x31.5 400880 QUOTE
JFC40K3/6-220/380-120/208 4032220/380 120/208 63x22x31.5 400880 QUOTE
JFC50K3/6-220/380-120/208 5040220/380 120/208 63x22x31.5 5501210 QUOTE
JFC60K3/6-220/380-120/208 6048220/380 120/208 63x22x31.5 6801495 QUOTE
JFC80K3/6-220/380-120/208 8064220/380 120/208 63×43.5×31.5 8201800 QUOTE
JFC100K3/6-220/380-120/208 10080220/380 120/208 63×43.5×31.5 9502090 QUOTE
JFC120K3/6-220/380-120/208 12096220/380 120/208 63×43.5×31.5 11802596 QUOTE
JFC160K3/6-220/380-120/208 160128220/380 120/208 63×43.5×31.5 14503190 QUOTE
JFC200K3/6-220/380-277/480 200160220/380 277/480 63×87.0x31.5 25005500 QUOTE
JFC240K3/6-220/380-277/480 240192220/380 277/480 63×87.0x31.5 27005940 QUOTE
JFC300K3/6-220/380-277/480 300240220/380 277/480 63×87.0x31.5 30006600 QUOTE
JFC320K3/6-220/380-277/480 320256220/380 277/480 63×87.0x31.5 31006800 QUOTE
JFC450K3/6-220/380-277/480 450360220/380 277/480 63x130x31.5 45009900 QUOTE
JFC600K3/6-220/380-277/480600480220/380277/48075x154x39.5500011000 QUOTE
400 Hz Three-Phase Output Models

MODELKVAKWIN (VAC) OUT (VAC) SIZE IN.(HXWXL) WEIGHT (KG) WEIGHT (LBS) OUTLINE DRAWING
JFC10K3/4-120/208-115/200 108120/208 115/200 63x22x31.5 270590 QUOTE
JFC20K3/4-120/208-115/200 2016120/208 115/200 63x22x31.5 310680 QUOTE
JFC30K3/4-120/208-115/200 3024120/208 115/200 63x22x31.5 4601010 QUOTE
JFC40K3/4-120/208-115/200 4032120/208 115/200 63x22x31.5 5501170 QUOTE
JFC50K3/4-120/208-115/200 5040120/208 115/200 63x22x31.5 6201360 QUOTE
JFC60K3/4-120/208-115/200 6048120/208 115/200 63x22x31.5 7301605 QUOTE
JFC80K3/4-120/208-115/200 8064120/208 115/200 63×43.5×31.5 8701910 QUOTE
JFC100K3/4-120/208-115/200 10080120/208 115/200 63×43.5×31.5 11002200 QUOTE
JFC120K3/4-120/208-115/200 12096120/208 115/200 63×43.5×31.5 12202680 QUOTE
JFC160K3/4-120/208-115/200 160128120/208 115/200 63×43.5×31.5 12202680 QUOTE
JFC200K3/4-277/480-115/200 200160277/480 115/200 63×87.0x31.5 25005500 QUOTE
JFC240K3/4-277/480-115/200 240192277/480 115/200 63×87.0x31.5 27005940 QUOTE
JFC300K3/4-277/480-115/200 300240277/480 115/200 63×87.0x31.5 30006600 QUOTE
JFC320K3/4-277/480-115/200 320256277/480 115/200 63×87.0x31.5 31006820 QUOTE
JFC450K3/4-277/480-115/200 450360277/480 115/20063x130x31.5 45009900 QUOTE
JFC600K3/4-277/480-115/200600480277/480115/20075x154x39.5500011000 QUOTE
JFC900K3/4-277/480-115/200900720277/480 115/20075x176x39.5750016500 QUOTE
Partial Single-Phase Output Frequency Converter Model Selection

MODELKVAKWINPUT OUTPUT SIZE IN.(HXWXL) WEIGHT (KG) WEIGHT (LBS) OUTLINE DRAWING
JFC10K50-120-220 108120 VAC, 60 Hz, Single-Phase220 VAC, 50 Hz, Single-Phase 63x22x31.5 270590 QUOTE
JFC10K50-120/208-220108120/208 VAC, 60 Hz, Three-Phase 220 VAC, 50 Hz, Single-Phase 63x22x31.5 270590 QUOTE
JFC10K60-220-120 108220 VAC, 50 Hz, Single-Phase 120 VAC, 60 Hz, Single-Phase63x22x31.5 270590 QUOTE
JFC10K60-220/380-120 108220/380 VAC, 50 Hz, Three-Phase 120 VAC, 60 Hz, Single-Phase63x22x31.5 270590 QUOTE
JFC10K400-120-115 108120 VAC, 60 Hz, Single-Phase115 VAC, 400 Hz, Single-Phase63x22x31.5 270590 QUOTE
JFC10K400-120/208-115 108120/208 VAC, 60 Hz, Three-Phase115 VAC, 400 Hz, Single-Phase63x22x31.5 270590 QUOTE
JFC20K50-120-220 2016120 VAC, 60 Hz, Single-Phase220 VAC, 50 Hz, Single-Phase63x22x31.5 310680 QUOTE
JFC20K50-120/208-2202016120/208 VAC, 60 Hz, Three-Phase 220 VAC, 50 Hz, Single-Phase63x22x31.5 310680 QUOTE
JFC20K60-220-120 2016220 VAC, 50 Hz, Single-Phase120 VAC, 60 Hz, Single-Phase63x22x31.5 310680 QUOTE
JFC20K60-220/380-120 2016220/380 VAC, 50 Hz, Three-Phase120 VAC, 60 Hz, Single-Phase 63x22x31.5 310680 QUOTE
JFC20K400-120-115 2016120 VAC, 60 Hz, Single-Phase115 VAC, 400 Hz, Single-Phase 63x22x31.5 310680 QUOTE
JFC20K400-120/208-1152016120/208 VAC, 60 Hz, Three-Phase 115 VAC, 400 Hz, Single-Phase 63x22x31.5 310680 QUOTE
JFC30K50-120-2203024120 VAC, 60 Hz, Single-Phase220 VAC, 50 Hz, Single-Phase 63x22x31.5 4601010 QUOTE
JFC30K50-120/208-2203024120/208 VAC, 60 Hz, Three-Phase220 VAC, 50 Hz, Single-Phase 63x22x31.5 4601010 QUOTE
JFC30K60-220-1203024220 VAC, 50 Hz, Single-Phase120 VAC, 60 Hz, Single-Phase63x22x31.5 4601010 QUOTE
JFC30K60-220/380-1203024220/380 VAC, 50 Hz, Three-Phase120 VAC, 60 Hz, Single-Phase63x22x31.5 4601010 QUOTE
JFC30K400-120-115 3024120 VAC, 60 Hz, Single-Phase115 VAC, 400 Hz, Single-Phase63x22x31.5 4601010 QUOTE
JFC30K400-120/208-115 3024120/208 VAC, 60 Hz, Three-Phase115 VAC, 400 Hz, Single-Phase63x22x31.5 4601010 QUOTE

Specifications for the Nova Jupiter Frequency Converter

3-Phase Input/ 3-Phase Output
KVA 10 20 30 40 50 60 80 100 120 160 240 320 450
AC INPUT
Input Voltage (VAC) Please Specify | 115/200 | 120/208 | 220/380 | 230/400 | 240/415 | 277/480 WYE
220 3 ph delta | 240 3 ph delta | 380 3 ph delta | 400 3 ph delta | 480 3 ph delta
Single Phase available optionally – consult factory for details
Input Range +/- 20% (>+20% is available upon request)
Input Frequency 50/ 60 + 5Hz
Power Walk In 0% – 100% :20 sec
Rectifier 98%
Rectification Type 6 Pulse Standard, 12 Pulse Optional 12 Pulse Standard
Battery Start Yes, UPS can be started without AC source.
INVERTER (AC output)
Output Voltage (VAC) Please Specify | 115/200 | 120/208 | 220/380 | 230/400 | 240/415 | 277/480 WYE
220 3 ph delta | 240 3 ph delta | 380 3 ph delta | 400 3 ph delta | 480 3 ph delta
Single Phase available optionally – consult factory for details
Wave Form Sinewave
Output Power Factor 0.7 lead to lag
Output Frequency (free running) 50/60/400 Hz +/- 1Hz (crystal controlled) please specify
Phase Shift Under 100% Unbalanced Load <0.5%
THD (Linear Load) < 2%
Overload
<110% Continuous
110-125% Up to 15 minutes
125-150% Up to 10 minutes
>150% Up to 1 minute
Efficiency (100% Load) 93% 93% 93% 93.5% 93.5% 94% 94.5% 94.5% 95% 95% 95% 95% 95%
Overall Characteristics
Overall Efficiency 91% 91% 91% 91.5% 92% 92% 92.5% 92.5% 93% 93% 93% 93% 93%
Maximum Heat Dissipation (kw) 0.7 1.4 1.9 2.6 3 3.5 4.6 5.4 6.5 8.7 13 17.4 25.2
BTU/h @ Full Load 2.4K 4.8K 6.5K 8.9K 10.3K 12K 16K 19K 22K 30K 45K 60K 86K
Audible Noise <65 dBA (at 1m) <67dBA (at 1m)
Temperature 0-40ºC (32-104ºF) (Other ranges available)
Humidity 0%-95% (Non-condensing)
Altitude <1500 m Above Sea Level
EN50091-1, -2 Yes
Short Circuit Protection Yes
MTBF As per MIL-HDBK-217:30,000 Hours
As per Field Experience >100,000 Hours for loss
of AC Output
Lightning / EMC Filter MOV / Input & Output ( FCC CLASS A)
Galvanic Isolation Input and Output True Galvanic Isolation
LED, LCD, Audible Alarm Yes
Remote Control and Communication Interface Choices Dry Contact, RS-232, RS-485 (Optional,) UPScan Monitoring 1~99 Units Simultaneously (Optional,) Netagent (Optional,) MODBUS (Optional)

MONITORING FEATURES

  • The unit includes an RS232 communication option called UPSCOM which can monitor the output parameters and any abnormal conditions that have occurred in real time.

FRONT PANEL LCD DISPLAY AND LED INDICATORS

  • This will report all parameters including input and output voltages, currents, frequency, battery voltage, battery current, and many other functions.

LCD DISPLAY

  • Real time status, data, and historical events are displayed via the LCD display. The FC parameters, real-time clock, inverter, and buzzer can also be set through this LCD, which is backlit by LEDs for visual clarity.

STATUS LEDs

LEDs representing all important operational information provide feedback to the user. LED descriptions are as follows:

  • INVERTER ON – FC is running normally.
  • SHORT CIRCUIT – output is in short circuit state.
  • FUSE / OVERTEMP SD – shut down due to either fuse open or over temperature.
  • INVERTER FAIL SHUTDOWN – shut down due to low inverter AC output voltage.
  • HIGH DC SHUTDOWN – shut down due to high DC bus.
  • OVERLOAD SHUTDOWN – shut down due to overload of the inverter for a period greater than the inverter can accept. The UPS will start after 7 seconds.
    70% LOAD – load connected to the output is over 70% of the Inverter rating.
    110% LOAD – load connected to the output is over 110% oh the Inverter rating.
    125% LOAD – load connected to the output is over 125% of the Inverter rating.
    150% LOAD – load connected to the output is over 150% of the Inverter rating.
  • RESERVE AC FAIL – reserve AC magnitude is out of range.
  • RESERVE FREQ FAIL – reserve frequency is out of range.
  • BATTERY LOW – DC bus (or battery) is lower than specified range, low battery shutdown will occur soon.
  • BATTERY LOW SHUTDOWN – inverter shutdown due to DC bus (or battery) lower than the acceptable DC voltage of the inverter.
  • HIGH DC – DC voltage over the acceptable DC voltage of the inverter.
  • EMERGENCY STOP – Inverter shut down activated by emergency stop switch.
  • DATA LINE – Blink when data is transmitted to or received from the communication port

WARNING LEDs

When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. These LEDs are:

  • RESERVE FAIL – Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range.
  • FUSE/TEMP – Either inverter fuse is open or over temperature has occurred.
  • OVERLOAD – Output is overloaded by over 110%, 125% or 150%
  • HIGH DC – This LED will light when DC input approaches high-line limit.
  • BAT LOW – This LED will light when the DC voltage is low.
  • BAT LOW STOP – This LED will light when the DC voltage is lower than specified range.
  • FAULT – The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop.

AUDIBLE ALARM

The audible alarm will beep under either one of the following conditions:

  • INVERTER IS OVERLOADED –
    > 110% beep once every 3 seconds
    > 125% beep once every second
    > 150% beep twice every second
  • INVERTER IS SHORT CIRCUITED – Beeps continuously
  • FUSE OPEN– Beeps continuously
  • HEAT SINK OVER TEMPERATURE – Beeps continuously
  • HIGH DC SHUTDOWN – Beeps continuously
  • BYPASS ON STOP – Beeps continuously
  • EMERGENCY ON STOP – Beeps continuously
    The buzzer will also beep once every time the inverter is switched on or off to acknowledge to the user that his key entry is valid and accepted.temperature, bypass breaker on emergency stop.

OPTIONS

    • UPScan Remote Monitor Panel: This is a hand held remote display and control module with LCD and LED display that can monitor up to 99 FCs at a remote distance of up to 3,000 feet via RS-485.
    • RuggedizationRuggedization is highly recommended for harsh environment applications, and includes conformal coating of the FC’s PCBs to protect against humidity, condensation, and fungus growth. For military applications, we offer more structural ruggedization, as well as shock mounts, to comply with such standards as MIL-S-901, MIL-STD-810, and other demanding MIL-Specs. This option does not affect size or weight.
    • NETAGENT:  This provides capability to monitor the FC over the internet.  It includes the appropriate additional SNMP card and microprocessor.  The software required is provided by Megatec at additional cost.  When equipped with this option, the user can connect a CAT-5 cable for interface to the external LAN.
    • Complete Spare Parts Package: We offer a comprehensive spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans.  These spare parts kits are priced lower when ordered with the initial order then if they are ordered later on.
    • Factory Turn-On Service: We offer a turn on service for a fee that will ensure the unit has been properly installed and the full warranty is in effect.  (Failures caused by incorrect installation are not covered by the warranty.)  If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.  This service is provided by factory engineers, not third party engineers. Pricing is dependent upon location, number of units, airfare rates, etc. Please contact us for more details if interested.
    • Customized EPO: This Emergency Power Off (EPO) Feature can be tailored to trip off current breakers or perform other inhibits per specific customer applications.
    • Shock and Vibration Mounts: A wide selection of mounts are available for compliance to MIL-S-901, MIL-STD-167, and other related standards.
    • Drip Shields for protection against falling or dripping liquids
    • AUX DC Outputs
    • Output Voltage Adjustment Knob +/-10%
    • Casters for Portability (22″ Wide Models Only)
    • Power Distribution Units (PDUs)
    • Environmental Stress Screening Services

IEC 62040-2 (for 220/380 VAC, 50 Hz Models except 320+ KVA)
EN50091-1
EN50091-2
FCC Class A

Jupiter-Series Models can be equipped with options to meet*:

MIL-STD-810 – for shock, vibration, humidity, and temperature
MIL-STD-167 – for vibration
MIL-STD-461 – for EMI
MIL-S-901 – for shock
MIL-STD-1399 – for shipboard power

*Compliance to these “designed to meet” standards based on similarity to previously qualified designs. Formal Qual Testing to these and other standards is available optionally.

Jupiter Series 10-450 KVA High Power Solid-State Frequency Converters PDF Data Sheet