Galaxy Series Ultra Lightweight RTCA/DO-160G Compliant Aircraft Grade 0.9-5 KVA UPS Systems

  • Formally Qualified to RTCA/DO-160, MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD-1399
  • Compact Chassis (1U – 5U Tall)
  • Ultra Lightweight Design
  • Power Factor Corrected Input (Single-Phase Input Models)
  • SNMP Communications
  • Lithium Iron Phosphate Batteries Available Optionally
  • Double-Conversion UPS Systems
  • Rack-Mount, Double-Conversion UPS Systems
  • Rugged UPS System
  • Military UPS System
  • True Online UPS Technology
Compare

Description

WHEN EVERY POUND COUNTS! Nova’s Ultra Lightweight Galaxy-Series rugged, military UPS systems are high-reliability power sources specifically designed for demanding aircraft applications in high shock, vibration, humidity, and EMI environments in compliance to RTCA/DO-160, MIL-STD-461, and MIL-STD-810. These rugged UPS models utilize True On-Line technology, offering maximum field-proven reliability for severe environment and high reliability applications.

These are the UPSs of choice for all branches of the US Armed Forces, Boeing, EADS, and many other high profile airborne applications worldwide. Typically, these rugged UPS models have aircraft power input of 115/200 VAC, 400Hz, three-phase wye, although single-phase input is also available at no extra cost.

RTCA/DO-160G Qualified: Select units were tested successfully by Boeing and Rockwell Collins to meet RTCA/DO-160G for:

  • Rapid Decompression: Section 4 Cabin Pressure (8K) to Max Operating Alt (35K) in 15 sec; Hold for 10 min
  • Crash Safety Sustained: Section 7, Cat B – Up = 3.0g – Down = 6.0g – Fwd = 9.0g – Aft = 1.5g – Side =4.0g
  • Explosive Atmosphere: Non-Ignition Test Sec. 9.6.2, Cat E
  • Humidity: Section 6, paragraph 6.3.1 (Category A)
  • Random Vibration Testing: Section 8 (Category R, Fixed-Wing), paragraph 8.7.2, Figure 8-1: Aircraft Type 2, Test Category S, Zone 2, Curve B
  • Operational Shock Testing: Section 7 (Category B), paragraph 7.2, Standard operational, Peak value 6 g, Nominal duration 11 ms.

Additional Ruggedization to meet MIL-STD-810: The UPS System’s construction is extremely robust, and ruggedized throughout. All components and modules within the UPS are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth. For additional protection against humidity, optional low-draw heating elements can be included within the unit, and optional drain holes can be placed strategically in the base of the chassis to allow any formed condensation to escape.

Partial Model Selection

MODELKVAKWNOMINAL INPUTINPUT (Amps)UPS (Lbs)RUN TIMEHEIGHTOUTLINEVIDEO
GRSLPFC11-5K60-115/200-120-5M-5U 5 4115/200 VAC three-phase15A 1104 min @ 3 kw 5U QUOTE
GRSLPFC11-5K60-115/200-120-5M-5U-LIFE 5 4115/200 VAC three-phase15A 754 min @ 3 kw 5U QUOTE
GRSLPFC11-3K60-115/200-120-5M-4U 33115/200 VAC three-phase11A 955 min4U QUOTE
GRSLPFC11-3K60-115/200-120-5M-4U-LIFE 33115/200 VAC three-phase 9A 705 min 4U QUOTE
GRSLPFC11-3K60-115/200-120-10M-4U 32.4115/200 VAC three-phase9A 957 min4U QUOTE
GRSLPFC11-3K60-115/200-120-5M-3U 32.4115/200 VAC three-phase9A 805 min3U QUOTE
GRSLPFC11-3K60-115/200-120-5M-3U-LIFE 32.4 115/200 VAC three-phase9A 655 min 3U QUOTE
GRSLPFC11-2K60-115/200-120-5M-3U 21.6115/200 VAC three-phase6A807 min 3U QUOTE
GRSLPFC11-2K60-115/200-120-5M-3U-LIFE 21.6115/200 VAC three-phase 6A657 min 3U QUOTE
GRSLPFC11-1.5K60-115/200-120-5M-2U 1.51.2 115/200 VAC three-phase5A605 min2U QUOTE
GRSLPFC11-1.5K60-115/200-120-5M-2U-LIFE 1.51.2 115/200 VAC three-phase5A3710 min 2U QUOTE
GRSLPFC11-1K60-115/200-120-10M-1U-LIFE 0.90.7115/200 VAC three-phase8/4A2510 min.1U QUOTE
ELECTRICAL
  • Input Voltage: 115 VAC 1Ø PFC or 115/200 VAC 3Ø  (120/240 VAC Autoselect PFC optional)
  • Output Voltage: 115, 120, 208, or 230 VAC (specify)
  • Frequency: 50 / 60 / 400 Hz. Available
  • Voltage Regulation: ± 2% NL to FL
  • Frequency Regulation: ± 0.5% NL to FL
  • Harmonic Distortion: 5% THD, 3% typical
  • Input Power Factor: 0.95 or Better @ half-full load
  • Efficiency at full load: 80-85% @ full load typical (batteries charged)
  • Connections: MS Connector (mates opt.)
NOMINAL DIMENSIONS
  • UPS Dimensions:19″ Wide x 24″ Deep (See chart for height)
  • External Battery Dimensions (5KVA External Battery Models):
    5.25 high x 19” wide x 24” deep – Outline Drawing pdf_icon
    [typography font=”Cantarell” size=”11″ size_format=”px” color=”#000000″]Note: External batteries available on all models if increased run time is required – up to 24 hours.[/typography]
PROTECTIVE FEATURES
  • AC & DC Input Circuit Breakers
  • Low Battery
  • Shut Off, Overload & Thermal Protected
  • Input Under/Overvoltage Protected
  • Audible Alarm with Silence Switch.
ENVIRONMENTAL
  • UPS Operating Temp.:
    • -20° to +55°C (Extended ranges optional)
  • UPS Storage temperature range:
      -40° to +71°C (Electronics Only – Extended ranges optional)
  • Humidity:
    • to 95% RH non-condensing – Designed to meet MIL-STD-810 optionally. All boards conformal coated with Acrylic MIL-I-46058 Type R.
  • Elevation:
    • 15,000 Ft. (4,572m) operating;
    • 40,000 ft. (12,192m) non-operating (higher optional)
  1. Shock:
    • 20g, 11 mS half sinewave – Designed to meet MIL-STD-810
  • Audible Noise:
    • Less than 55 dbA at 5 ft.
  • Battery Storage Temperature Range:
    • -20° to +50°C (Standard)

-40° to +80° C (Optional) Using premium VRLA batteries.

      • Note: Run time shown using standard batteries. Consult Factory for run times using premium batteries. For best results, batteries must be kept at 25 degrees Celsius ambient temperature. Extreme low temperatures will result in reduced run time, while extreme high temperatures result in significantly reduced battery lifespan. For more information, please read our Application Note –

    The Effects of Extreme Temperatures on Batteries.

  • MTBF: 100,000+ hours per field data @ +25C Ambient Ground-Fixed
  • MTTR: 30 minutes by qualified personnel
ELEVATION
  • 15,000 ft. (4,572 m) operating**
  • 40,000 ft. (12,192 m), non-operating

**For batteries, please follow battery manufacturer instructions regarding recommended elevation parameters.

STANDARD REMOTE CONTACTS / COMMUNICATIONS
  • SNMP V1.0 standard via CAT-5 Connector – V2.0 or 3.0 optional
  • Major Alarm: Logic Fault, Low Battery, OT, UPS Overloaded.
  • Minor Alarm: Utility Off
  • RS 232 (Available-Optional) Via DB 9 Connector
  • Alarm Contacts (Available-Optional)
STANDARD FRONT PANEL DIAGNOSTICS
  • Status (Red / Green)
  • UPS Off (Red)
  • Logic Fault (Red)
  • Low Battery (Red)
  • Over Temperature (Red)
  • Load on Utility (Red) with optional transfer switch
  • Power Distribution Units
  • MS Connector Mates and Multiple Output Outlets
  • Chassis Slide Guides
  • Internal Transfer Switch (Static or Electromechanical)
  • Rugged Transit Cases and Custom Enclosures
  • Additional Run Time via External Batteries
  • 3Ø Power Input
  • Premium VRLA Batteries with Up to 12 Year Life
  • 400 Hz Input and / or Output
  • LiFe Models Feature Internal Lithium Iron Phosphate Batteries for Substantial Weight Savings and Longer Runtime, Including Embedded Battery Management System
  • CAD Free Connectors
  • Non-PVC wiring
  • 28 VDC Input
  • 28 VDC Output Instead of AC Output (1U Models Only)
  • High IP Protection for front / rear panels
  • AUX DC Outputs
  • Environmental Stress Screening Services

RTCA/DO-160G Qualified: Select units were tested successfully by Boeing and Rockwell Collins to meet RTCA/DO-160G for:

  • Rapid Decompression: Section 4 Cabin Pressure (8K) to Max Operating Alt (35K) in 15 sec; Hold for 10 min
  • Crash Safety Sustained: Section 7, Cat B – Up = 3.0g – Down = 6.0g – Fwd = 9.0g – Aft = 1.5g – Side =4.0g
  • Explosive Atmosphere: Non-Ignition Test Sec. 9.6.2, Cat E
  • Humidity: Section 6, paragraph 6.3.1 (Category A)
  • Random Vibration Testing: Section 8 (Category R, Fixed-Wing), paragraph 8.7.2, Figure 8-1: Aircraft Type 2, Test Category S, Zone 2, Curve B
  • Operational Shock Testing: Section 7 (Category B), paragraph 7.2, Standard operational, Peak value 6 g, Nominal duration 11 ms.

MIL-STD-1399 Section 300B: For Type I apparatus

MIL-STD-740-1: Airborne Sound Measurements for Shipboard Equipment

MIL-STD-740-2: Structureborne Vibratory Acceleration Measurements

Additional Ruggedization to meet MIL-S-901, MIL-STD-167, MIL-STD-810, and DOD-STD-1399: The UPS System’s construction is extremely robust, and ruggedized throughout. All components and modules within the unit are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth.

MIL-S-901D for Grade A, Class II, Type B Equipment (mounted in shock-isolated rack attenuating to 20g/11ms max)

MIL-STD-167-1 for Type I Equipment

MIL-STD-810:

· Air Temperature per MIL-STD-810F Method 502.4, Procedure II
· Steady State Temperature per MIL-STD-810F, Method 501.4, Procedure I (Constant Temperature) and Method 502.4, Procedure I
· Temperature Shock per MIL-STD-810F, Method 503.4, Procedure II, Cyclic.
· Thermal Shock testing per MIL-STD-810G, Method 503.5, Procedure I-D
Operating Temperature Shock per MIL-STD-810B Method 503 0 to 71°C
· High Temperature Storage per MIL-STD-810G, Method 501.5, Procedure I
· Low Temperature Storage testing per MIL-STD-810G, Method 502.5, Procedure I
· High Temperature Operating per MIL-STD-810G, Method 501.5, Procedure II
· Low Temperature Operating per MIL-STD-810G, Method 502.5, Procedure II
· Operational Humidity per MIL-STD-810F Method 507.4.
· Humidity per MIL-STD-801G, Method 507.5, Procedure I
· Storage and Transportation Humidity per MIL-STD-810F, Method 507.4
· Salt Fog Atmosphere per MIL-STD-810F Method 509.4
· Altitude per MIL-STD-810F, Method 500.4, Procedure I, Storage/Air Transport.
· Operating and Non-Operating Altitude Testing per MIL-STD-810G, Method 500.5, Procedure II
· Rapid Decompression per MIL-STD-810F, Method 500.4, Procedure III
· Transit Shock per MIL-STD-810F, Method 516, Procedures IV, V and VI
· Transportation Vibration per MIL-STD-810F, Method 514.5, Procedure II for loose cargo transportation
· Transportation Vibration per MIL-STD-810G, Method 514-6, Procedure I, Category 20
· Vibration per MIL-STD-810B Method 514.6, Category 12, Procedure I
· Transit Drop per MIL-STD-810F, Method 516.5, Procedure IV
· Transit Drop per MIL-STD-810G, Method 516.6, Procedure IV
· Bench Handling per MIL-STD-810F, Method 516.5, Procedure VI
· Bench Handling per MIL-STD-810G, Method 516.6, Procedure VI

DOD-STD-1399 Section 301A Table V – Design Limits for Ship Motion

Internal EMI Reduction Package to meet MIL-STD-461: The Ultra Lightweight UPS Systems shown herein are designed to comply with the requirements of MIL-STD-461E using shielded input, output, and data cables. Test data to other revisions of MIL-STD-461 is available for select models. (If the input and output cables are not shielded, additional filtering may be required for full compliance to MIL-STD-461.) All single-phase input units in this series are equipped with active Power factor Correction which allows full compliance to the input  current requirements of MIL-STD-1399 and the CE101 limit of MIL-STD-461.

Please note: Not all models and choices of input voltages and output voltages shown in the model chart have been formally tested for each of the following MIL-STD-461E parameters shown below. In such cases, Nova cannot guarantee full compliance without a formal testing program for your specific UPS configuration, available optionally. Please consult the factory for details.

MIL-STD-461E: CE101, CE102, CS101, CS114, CS116, RE102, RS101, and RS103.

Note: Qualification testing on select models was performed with optional premium batteries required to meet temperature testing requirements. Please consult factory for details.

Galaxy Series Ultra Lightweight 0.9-5 KVA Rugged True Online UPS PDF Data Sheet