AET Series 1.5 – 3.2 KVA Single Phase Output True Online COTS UPS
True Online Backup Power for Commercial and Industrial Applications such as:
- Communication Equipment
- Network Servers
- Computers
- Workstations
- Wireless Communications
- Other Electronic Peripherals
- 19″ Rack Mount Brackets Included
- Vertical Mounting Feet Included
- Description
- Specifications
- Popular Options
- Videos
- Data Sheets
Description
Nova’s AET-Series True Online UPS Systems are high-reliability power sources specifically designed for demanding commercial and industrial applications. The AET models come complete with both 19” Rack Mount Brackets and Vertical Mount Bases, allowing maximum installation flexibility. These models utilize the most durable components, offering maximum field-proven reliability for applications such as:
- Communication Equipment
- Network Servers
- Computers
- Workstations
- Wireless Communications
- Other Electronic Peripherals
FEATURES AND BENEFITS
Flexible Mounting Orientation
Allows system integrators more flexibility in designing their backup power system to maximize space. With the rotatable LCD design, the user can mount the UPS vertically or horizontally.
User-Friendly Graphic LCD
This robust LCD display enables field service engineers to easily troubleshoot the UPS without opening the box, reducing downtime.
Single Voltage Battery Pack Design
A 48 VDC standard battery pack design comprised of 4 x 12V 7AH cells is used in all AET Series UPS models, and are interchangeable with each other.
Additional battery drawers can be added to increase battery runtime.
Hot-Swappable Battery
The standard 48 VDC battery pack allows installers to take the headache out of battery installation. Installers can now simply slide the used battery pack out of the unit and replace it with a new pack. All AET battery packs are interchangeable.
Light Weight Design
The AET is designed for easy field installation. The light weight design requires only a single installer to put the system in place. This will significantly reduce on-the-job injuries and installation fees.
User-Remote Interface
The off-site user can now test, set parameters, monitor power status, save files, and shutdown the system all via the remote interface. The user-remote interface includes SNMP/HTTP Card, RS232, USB, DB9, and AS400 interface.
INTELLIGENT POWER MANAGEMENT SOFTWARE
CRUISER SOFTWARE (INCLUDED)
Users are able to customize the various Cruiser controls such as warning method, alarm messages and several shortcut icons to easily access the most commonly used functions. The Cruiser software can send warning messages to a pager, via e-mail or over the LAN, thus providing an early warning system for power failures, system shutdown and variety of other scenarios. It guarantees a faster response time, even when you are not in the office.
Features:
- Green mode supported
- PFC Status Display
- Cross platform supported
- UPS monitoring utility
- Scheduled system shutdown
- Graphic display of UPS status
- Warning notification via e-mail or pager
- Customized controls
- User definable warnings
- Multi-language versions
- “Read & Write” functions when setting output voltage and frequency (Optional)
Interface & OS Compatibilities
RS 232 (Standard)
Windows: Win95, WinNT4.0, Win98SE, Win2000, WinMe, WinXP
Linux: 7.0 ~ 7.3, 8.0 ~ 8.4, 9.0
Mandrake: 8.2, 8.3, 8.4, 9.0
Novell: 4.x, 5.1
USB (Optional Card)
Windows: Win 98SE, Win2000, WinME, WinXP
Other major UPS monitoring software and SNMP / HTTP Cards compatible with all AET Series UPS
-
Internal or External Networking Card: Net Agent II or USHA PRO (SNMP,HTTP, PPP, TCP/IP, etc.)
-
UPSilon via RS232
- RUPS via Contact Closure (DB9)
120 VAC MODELS
PARTIAL MODEL NAME | AET11-1.5K | AET11-2.2K | AET11-3K |
---|---|---|---|
Outline Drawing | Click Here | Click Here | Click Here |
Topology | True On-Line, Double Conversion |
||
On-battery Output Waveform | Pure Sinewave |
||
Number of Phase | Single (1Phase 2W + G) |
||
INPUT | |||
Maximum Capacity (VA/W) | 1500VA / 1050W | 2200VA / 1540W | 3000VA / 2100W |
Nominal Input Voltage | 120 VAC |
||
Input Voltage Range | 80 to 138VAC |
||
Nominal input Frequency | 50/60 Hz +/- 5 Hz |
||
Input PFC | >0.98 @ full load |
||
Input Short Protection | Circuit Breaker on front of the UPS |
||
OUTPUT | |||
Nominal Output Voltage | 100/110/115/120VAC |
||
Output Voltage Regulation | Rated Voltage +/-2% |
||
Output T.H.D. | <3% @ Linear Load |
||
High Efficiency Mode (AC to AC) | >86% | >88% | >88% |
Crest Factor | 3:1 |
||
Start on Battery | Yes |
||
Output Frequency | 50/60Hz (Autotracking) |
||
Overload Capacity | Sustaining at least 120 seconds at 101-110% load, 111-150% max 12 seconds. Immediate shutdown and transfer of load to bypass at 150% load. Auto transfer back to UPS when overload is removed |
||
BATTERY | |||
User Repleaceable Battery | 1 x 48VDC Battery Pack | 96V (2 x 48VDC)Battery Pack | 96V (2 x 48VDC)Battery Pack |
Typical Backup Time (Full/Half Load) | 6 / 17 minutes | 9 / 26 minutes | 6 / 17 minutes |
Battery Pack Outline Drawing | CLICK HERE | ||
Battery Type | Sealed VRLA 12V7AH; Hot Swap |
||
Recharge Time to 90% | 8 Hours |
||
Extended Battery Drawers | Additional Battery Module in 2U high (comprises 2 x 48VDC Battery Packs) Model AETPC |
||
Operation | Transition from or to battery operation is accomplished with no interruption of power to the load. Upon restoration of input power, the UPS will automatically resume normal operation and recharge the battery |
||
ADVANCE WARNING DIAGNOSTICS | |||
Communication Port | RS 232 Port (Standard); DB9, AS400, USB Cards (Optional) |
||
SNMP Manageable | Yes (Optional) | ||
ENVIRONMENTAL | |||
Temperature (Operation/Storage) | 0 ºC to + 40 ºC / -15 to + 50 ºC |
||
Relative Humidity | 0% to 95% non-condensing |
||
Altitude | Up to 10,000 ft (3,000 meters) at up to 40 ºC, without derating |
||
Audible Noise | <45 dBA @ 1 meter |
||
MECHANICAL | |||
Dimensions – (WxHxD) Note: Change W to 19 in. for Rack Mount Configuration | 16.77 x 3.46 (2U) x 19.7 (in) 426 x 88(2U) x 500 (mm) | 16.67 x 6.93(4U) x 19.7 (in) 426 x 176 (4U) x 500 (mm) | 16.67 x 6.93 (4U) x 19.7 (in) 426 x 176 (4U) x 500 (mm) |
Weight (UPS/Battery Packs) | 26.4 / 24.6 lb 12 / 11.2 Kg | 29 / 68.7 lb 13.2 / 31.2 Kg | 29.5 / 69 lb 13.4 / 31.4 Kg |
Total Weight | 51lb / 23.2Kg | 97.7lb / 44.4Kg | 98.5lb / 44.6kg |
CONFORMANCE | |||
EMI/RFI Compatibility | FCC Part 15 Class B |
||
Safety | UL, cUL (CSA) |
220 VAC MODELS
PARTIAL MODEL NAME | AET11-1.6K | AET11-2.5K | AET11-3.2K |
---|---|---|---|
Topology | True On-Line, Double Conversion |
||
On-battery Output Waveform | Pure Sinewave |
||
Number of Phase | Single (1Phase 2W + G) |
||
INPUT | |||
Maximum Capacity (VA/W) | 1600VA / 1120W | 2500VA / 1750W | 3200VA / 2240W |
Nominal Input Voltage | 230 VAC |
||
Input Voltage Range | 160 to 276VAC |
||
Nominal input Frequency | 50/60 Hz +/- 5 Hz |
||
Input PFC | >0.98 @ full load |
||
Input Short Protection | Circuit Breaker on front of the UPS | ||
OUTPUT | |||
Nominal Output Voltage | 208/220/230/240VAC |
||
Output Voltage Regulation | Rated Voltage +/-2% |
||
Output T.H.D. | <3% @ Linear Load |
||
High Efficiency Mode (AC to AC) | >86% | >88% | >88% |
Crest Factor | 3:1 |
||
Start on Battery | Yes | ||
Output Frequency | 50/60Hz (Autotracking) |
||
Overload Capacity | Sustaining at least 120 seconds at 101-110% load, 111-150% max 12 seconds.Immediate shutdown and transfer of load to bypass at 150% load.Auto transfer back to UPS when overload is removed |
||
BATTERY | |||
User Repleaceable Battery | 1 x 48VDC Battery Pack | 96V (2 x 48VDC)Battery Pack | 96V (2 x 48VDC)Battery Pack |
Typical Backup Time (Full/Half Load) | 6 / 17 minutes | 9 / 26 minutes | 6 / 17 minutes |
Battery Pack Outline Drawing | CLICK HERE | ||
Battery Type | Sealed VRLA 12V7AH; Hot Swap |
||
Recharge Time to 90% | 8 Hours |
||
Extended Battery Drawers | Additional Battery Module in 2U high (comprises 2 x 48VDC Battery Packs) Model AETPC | ||
Operation | Transition from or to battery operation is accomplished with no interruption of power to the load. Upon restoration of input power, the UPS will automatically resume normal operation and recharge the battery | ||
ADVANCE WARNING DIAGNOSTICS | |||
Front Panel Indication | Front panel menu driven LCD monitoring and control panel for all functions | ||
Audible Alarms | DC Mode, Low Battery, voltage / Frequency Error, Charger Fail, Over Load, Fault, PFC Overload | ||
COMMUNICATION INTERFACE | |||
Communication Port | RS 232 Port (Standard); DB9, AS400, USB Cards (Optional) |
||
SNMP Manageable | Yes (Optional) | ||
ENVIRONMENTAL | |||
Temperature (Operation/Storage) | 0 ºC to + 40 ºC / -15 to + 50 ºC |
||
Relative Humidity | 0% to 95% non-condensing |
||
Altitude | Up to 10,000 ft (3,000 meters) at up to 40 ºC, without derating |
||
Audible Noise | <45 dBA @ 1 meter |
||
MECHANICAL | |||
Dimensions – (WxHxD)Note: Change W to 19 in. forRack Mount Configuration | 16.77 x 3.46 (2U) x 19.7 (in) 426 x 88(2U) x 500 (mm) | 16.67 x 6.93(4U) x 19.7 (in) 426 x 176 (4U) x 500 (mm) | 16.67 x 6.93 (4U) x 19.7 (in) 426 x 176 (4U) x 500 (mm) |
Weight (UPS/Battery Packs) | 26.4 / 24.6 lb 12 / 11.2 Kg | 29 / 68.7 lb 13.2 / 31.2 Kg | 29.5 / 69 lb 13.4 / 31.4 Kg |
Total Weight | 51lb / 23.2Kg | 97.7lb / 44.4Kg | 98.5lb / 44.6kg |
CONFORMANCE | |||
EMI/RFI Compatibility | EN50091-2 ClassB, EN55022B. IEC/EN61000-3-2 (Harmonic Current) |
||
Safety | CE, TUV, GS |
OPTIONS
- Ruggedization against high shock, vibration and humidity
- Chassis Slide Guides
- Additional run time via external batteries
- SNMP Communications
- DB9 Dry Relay Contacts
- External 500W 48VDC AETPC Battery Pack Charger (Multiple strings in each AET battery pack are put in parallel by the charger and then charged at 48 VDC)
- Power Distribution Units (PDUs)
- Environmental Stress Screening Services