AET Series 1.5 – 3.2 KVA Single Phase Output True Online COTS UPS

True Online Backup Power for Commercial and Industrial Applications such as:

  • Communication Equipment
  • Network Servers
  • Computers
  • Workstations
  • Wireless Communications
  • Other Electronic Peripherals
  • 19″ Rack Mount Brackets Included
  • Vertical Mounting Feet Included
Compare

Description

Nova’s AET-Series True Online UPS Systems are high-reliability power sources specifically designed for demanding commercial and industrial applications. The AET models come complete with both 19” Rack Mount Brackets and Vertical Mount Bases, allowing maximum installation flexibility. These models utilize the most durable components, offering maximum field-proven reliability for applications such as:

  • Communication Equipment
  • Network Servers
  • Computers
  • Workstations
  • Wireless Communications
  • Other Electronic Peripherals

 

FEATURES AND BENEFITS

Flexible Mounting Orientation
Allows system integrators more flexibility in designing their backup power system to maximize space. With the rotatable LCD design, the user can mount the UPS vertically or horizontally.

User-Friendly Graphic LCD
This robust LCD display enables field service engineers to easily troubleshoot the UPS without opening the box, reducing downtime.

Single Voltage Battery Pack Design
A 48 VDC standard battery pack design comprised of 4 x 12V 7AH cells is used in all AET Series UPS models, and are interchangeable with each other.
Additional battery drawers can be added to increase battery runtime.

Hot-Swappable Battery
The standard 48 VDC battery pack allows installers to take the headache out of battery installation. Installers can now simply slide the used battery pack out of the unit and replace it with a new pack. All AET battery packs are interchangeable.

Light Weight Design
The AET is designed for easy field installation. The light weight design requires only a single installer to put the system in place. This will significantly reduce on-the-job injuries and installation fees.

User-Remote Interface
The off-site user can now test, set parameters, monitor power status, save files, and shutdown the system all via the remote interface. The user-remote interface includes SNMP/HTTP Card, RS232, USB, DB9, and AS400 interface.

INTELLIGENT POWER MANAGEMENT SOFTWARE

CRUISER SOFTWARE (INCLUDED)
Users are able to customize the various Cruiser controls such as warning method, alarm messages and several shortcut icons to easily access the most commonly used functions. The Cruiser software can send warning messages to a pager, via e-mail or over the LAN, thus providing an early warning system for power failures, system shutdown and variety of other scenarios. It guarantees a faster response time, even when you are not in the office.

Features:

  • Green mode supported
  • PFC Status Display
  • Cross platform supported
  • UPS monitoring utility
  • Scheduled system shutdown
  • Graphic display of UPS status
  • Warning notification via e-mail or pager
  • Customized controls
  • User definable warnings
  • Multi-language versions
  • “Read & Write” functions when setting output voltage and frequency (Optional)

Interface & OS Compatibilities

RS 232 (Standard)
Windows: Win95, WinNT4.0, Win98SE, Win2000, WinMe, WinXP
Linux: 7.0 ~ 7.3, 8.0 ~ 8.4, 9.0
Mandrake: 8.2, 8.3, 8.4, 9.0
Novell: 4.x, 5.1

USB (Optional Card)
Windows: Win 98SE, Win2000, WinME, WinXP

Other major UPS monitoring software and SNMP / HTTP Cards compatible with all AET Series UPS

  • Internal or External Networking Card: Net Agent II or USHA PRO (SNMP,HTTP, PPP, TCP/IP, etc.)
  • UPSilon via RS232
  • RUPS via Contact Closure (DB9)

120 VAC MODELS

PARTIAL MODEL NAME AET11-1.5K AET11-2.2K AET11-3K
Outline Drawing Click HereClick HereClick Here
TopologyTrue On-Line, Double Conversion
On-battery Output Waveform Pure Sinewave
Number of Phase Single (1Phase 2W + G)
INPUT
Maximum Capacity (VA/W) 1500VA / 1050W 2200VA / 1540W 3000VA / 2100W
Nominal Input Voltage 120 VAC
Input Voltage Range 80 to 138VAC
Nominal input Frequency 50/60 Hz +/- 5 Hz
Input PFC >0.98 @ full load
Input Short Protection Circuit Breaker on front of the UPS
OUTPUT
Nominal Output Voltage 100/110/115/120VAC
Output Voltage Regulation Rated Voltage +/-2%
Output T.H.D. <3% @ Linear
Load
High Efficiency Mode (AC to AC) >86% >88% >88%
Crest Factor 3:1
Start on Battery Yes
Output Frequency 50/60Hz (Autotracking)
Overload CapacitySustaining at least 120 seconds at 101-110% load, 111-150% max 12 seconds.
Immediate shutdown and transfer of load to bypass at 150% load. Auto transfer back to UPS when overload is removed
BATTERY
User Repleaceable Battery 1 x 48VDC Battery Pack 96V (2 x 48VDC)Battery Pack 96V (2 x 48VDC)Battery Pack
Typical Backup Time (Full/Half Load) 6 / 17 minutes 9 / 26 minutes 6 / 17 minutes
Battery Pack Outline Drawing CLICK HERE
Battery Type Sealed VRLA 12V7AH; Hot Swap
Recharge Time to 90% 8 Hours
Extended Battery Drawers Additional Battery Module in 2U high (comprises 2 x 48VDC Battery Packs) Model AETPC
Operation Transition from or to battery operation is accomplished with no interruption of power to the load. Upon restoration of input power, the UPS will automatically resume normal operation and recharge the battery
ADVANCE WARNING DIAGNOSTICS
Communication Port RS 232 Port (Standard); DB9, AS400, USB Cards (Optional)
SNMP Manageable Yes (Optional)
ENVIRONMENTAL
Temperature (Operation/Storage) 0 ºC to + 40 ºC / -15 to + 50 ºC
Relative Humidity 0% to 95% non-condensing
AltitudeUp to 10,000 ft (3,000 meters) at up to 40 ºC, without derating
Audible Noise <45 dBA @ 1 meter
MECHANICAL
Dimensions – (WxHxD)
Note: Change W to 19 in. for Rack Mount Configuration
16.77 x 3.46 (2U) x 19.7 (in)
426 x 88(2U) x 500 (mm)
16.67 x 6.93(4U) x 19.7 (in)
426 x 176 (4U) x 500 (mm)
16.67 x 6.93 (4U) x 19.7 (in)
426 x 176 (4U) x 500 (mm)
Weight (UPS/Battery Packs) 26.4 / 24.6 lb
12 / 11.2 Kg
29 / 68.7 lb
13.2 / 31.2 Kg
29.5 / 69 lb
13.4 / 31.4 Kg
Total Weight 51lb / 23.2Kg 97.7lb / 44.4Kg 98.5lb / 44.6kg
CONFORMANCE
EMI/RFI Compatibility FCC Part 15 Class B
Safety UL, cUL (CSA)

220 VAC MODELS
PARTIAL MODEL NAME AET11-1.6K AET11-2.5K AET11-3.2K
Topology True On-Line, Double Conversion
On-battery Output Waveform Pure Sinewave
Number of Phase
Single (1Phase 2W + G)
INPUT
Maximum Capacity (VA/W)
1600VA / 1120W
2500VA / 1750W
3200VA / 2240W
Nominal Input Voltage
230 VAC
Input Voltage Range
160 to 276VAC
Nominal input Frequency
50/60 Hz +/- 5 Hz
Input PFC
>0.98 @ full
load
Input Short Protection
Circuit Breaker on front of the UPS
OUTPUT
Nominal Output Voltage
208/220/230/240VAC
Output Voltage Regulation Rated Voltage +/-2%
Output T.H.D.
<3% @ Linear
Load
High Efficiency Mode (AC to AC) >86% >88% >88%
Crest Factor 3:1
Start on Battery Yes
Output Frequency 50/60Hz (Autotracking)
Overload Capacity Sustaining at least 120 seconds at 101-110% load, 111-150% max 12 seconds.Immediate shutdown and transfer of load to bypass at 150% load.Auto transfer back to UPS when overload is removed
BATTERY
User Repleaceable Battery
1 x 48VDC Battery Pack
96V (2 x 48VDC)Battery Pack
96V (2 x 48VDC)Battery Pack
Typical Backup Time (Full/Half Load)
6 / 17 minutes
9 / 26 minutes
6 / 17 minutes
Battery Pack Outline DrawingCLICK HERE
Battery Type
Sealed VRLA 12V7AH;
Hot Swap
Recharge Time to 90%
8 Hours
Extended Battery DrawersAdditional Battery Module in 2U high (comprises 2 x 48VDC Battery Packs) Model AETPC
OperationTransition from or to battery operation is accomplished with no interruption of power to the load. Upon restoration of input power, the UPS will automatically resume normal operation and recharge the battery
ADVANCE WARNING DIAGNOSTICS
Front Panel Indication
Front panel menu driven LCD monitoring and control panel for all functions
Audible Alarms
DC Mode, Low Battery, voltage / Frequency Error, Charger Fail, Over Load, Fault, PFC Overload
COMMUNICATION INTERFACE
Communication Port
RS 232 Port (Standard);
DB9, AS400, USB Cards (Optional)
SNMP Manageable Yes (Optional)
ENVIRONMENTAL
Temperature (Operation/Storage)
0 ºC to + 40
ºC / -15 to + 50 ºC
Relative Humidity
0% to 95% non-condensing
AltitudeUp to 10,000 ft
(3,000 meters) at up to 40 ºC, without derating
Audible Noise <45 dBA @ 1
meter
MECHANICAL
Dimensions – (WxHxD)Note: Change W to 19 in. forRack Mount Configuration 16.77 x 3.46 (2U) x 19.7 (in)
426 x 88(2U) x 500 (mm)
16.67 x 6.93(4U) x 19.7 (in)
426 x 176 (4U) x 500 (mm)
16.67 x 6.93 (4U) x 19.7 (in)
426 x 176 (4U) x 500 (mm)
Weight (UPS/Battery Packs) 26.4 / 24.6 lb
12 / 11.2 Kg
29 / 68.7 lb
13.2 / 31.2 Kg
29.5 / 69 lb
13.4 / 31.4 Kg
Total Weight
51lb / 23.2Kg
97.7lb / 44.4Kg
98.5lb / 44.6kg
CONFORMANCE
EMI/RFI Compatibility
EN50091-2 ClassB,
EN55022B. IEC/EN61000-3-2 (Harmonic Current)
SafetyCE, TUV, GS

OPTIONS

AET Series 1 - 3.2 KVA Single Phase Output True Online COTS UPS PDF Data Sheet